LABORATOIRE D'HYGIÈNE ENVIRONNEMENTALE
AV DES TAMARIS, 13616, AIX EN PROVENCE, France
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at LABORATOIRE D'HYGIÈNE ENVIRONNEMENTALE?
Claim this profile to keep it accurate.
Register record
- COFRACRefreshed
- 1-6595Active
Accredited standards
6Our reading of the COFRAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
FD T 90-522Name not checked yet
FD T 90-522; FD T 90-521; FD T 90-520; NF EN ISO 19458
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
NF T 90-431; NF EN ISO 9308-1; NF EN ISO 7899-2; NF EN ISO 6222; NF T 90-412; HYG/ANA/PR06/MOP01; HYG/ANA/PR06/MOP02; HYG/ANA/PR06/MOP04
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
NF T 90-431; NF EN ISO 9308-1; NF EN ISO 7899-2; NF EN ISO 6222; NF T 90-412; HYG/ANA/PR06/MOP01; HYG/ANA/PR06/MOP02; HYG/ANA/PR06/MOP04
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
NF T 90-431; NF EN ISO 9308-1; NF EN ISO 7899-2; NF EN ISO 6222; NF T 90-412; HYG/ANA/PR06/MOP01; HYG/ANA/PR06/MOP02; HYG/ANA/PR06/MOP04
ISO 19458Water quality - Sampling for microbiological analysis
FD T 90-522; FD T 90-521; FD T 90-520; NF EN ISO 19458
NF T 90-431Name not checked yet
NF T 90-431; NF EN ISO 9308-1; NF EN ISO 7899-2; NF EN ISO 6222; NF T 90-412; HYG/ANA/PR06/MOP01; HYG/ANA/PR06/MOP02; HYG/ANA/PR06/MOP04
Scope as published by COFRAC
4 lines
ISO/IEC 17025
Active1-6595
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 1-6595
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | environmental | NF EN ISO/IEC 17025:2017 | ENVIRONNEMENT / QUALITE DE L'EAU | - |
| 2 | environmental | FD T 90-522; FD T 90-521; FD T 90-520; NF EN ISO 19458 | Drinking water | - |
| 3 | biological | NF T 90-431; NF EN ISO 9308-1; NF EN ISO 7899-2; NF EN ISO 6222; NF T 90-412; HYG/ANA/PR06/MOP01; HYG/ANA/PR06/MOP02; HYG/ANA/PR06/MOP04 | Surface water | - |
| 4 | biological | HYG/ANA/PR02/MOP02; HYG/ANA/PR02/MOP03; HYG/ANA/PR01/MOP07 | Solutions de contrôle des endoscopes | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in France
- TERANA DROMEVALENCE · ~162 kmCOFRACShares 4 accredited methods and materialsFD T 90-522NF T 90-431Drinking water
- ENIXUSMARTIGUES · ~37 kmCOFRACShares 3 accredited methods and materialsNF T 90-431Drinking waterSurface water
- NORMEC ABIOLABMONTBONNOT SAINT MARTIN · ~190 kmCOFRACShares 3 accredited methods and materialsNF T 90-431Drinking waterSurface water
- CARSO - LABORATOIRE SANTÉ ENVIRONNEMENT HYGIÈNE DE LYON (CARSO - LSEHL)VENISSIEUX · ~245 kmCOFRACShares 3 accredited methods and materialsNF T 90-431Drinking waterSurface water
- EUROFINS LANAGRAMMAZAMET · ~247 kmCOFRACShares 3 accredited methods and materialsNF T 90-431Drinking waterSurface water
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.