EMV Rhein-Neckar
Dornierstraße 5a, 68519, Viernheim, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at EMV Rhein-Neckar?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-19334-01-01Active
- D-PL-19334-01-00Active
Accredited standards
72Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 61000 series
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
DIN EN 55016 -2-1:2014 -12; DIN EN 55016 -2-2:2011 -09; DIN EN 55016 -2-3:2014 -11; DIN EN 61000 -3-2:2015 -03; EN 61000-3-2:2014
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
DIN EN 61000 -3-3:2014 -03; DIN E N 61000 -4-2:2009; DIN EN 61000 -4-3:2011 -04; DIN EN 61000 -4-4:2013 -04; DIN EN 61000 -4-5:2015 -03
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
DIN EN 61000 -3-3:2014 -03; DIN E N 61000 -4-2:2009; DIN EN 61000 -4-3:2011 -04; DIN EN 61000 -4-4:2013 -04; DIN EN 61000 -4-5:2015 -03
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
DIN EN 61000 -3-3:2014 -03; DIN E N 61000 -4-2:2009; DIN EN 61000 -4-3:2011 -04; DIN EN 61000 -4-4:2013 -04; DIN EN 61000 -4-5:2015 -03
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
DIN EN 61000 -3-3:2014 -03; DIN E N 61000 -4-2:2009; DIN EN 61000 -4-3:2011 -04; DIN EN 61000 -4-4:2013 -04; DIN EN 61000 -4-5:2015 -03
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
DIN EN 61000 -4-6:2014 -08; DIN EN 61000 -4-8:2010 -11; DIN EN 61000 -4-9:2017 -05; DIN EN 61000 -4-10:2001 -12; DIN EN 61000 -4-11:2005 -02
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
DIN EN 61000 -4-6:2014 -08; DIN EN 61000 -4-8:2010 -11; DIN EN 61000 -4-9:2017 -05; DIN EN 61000 -4-10:2001 -12; DIN EN 61000 -4-11:2005 -02
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
DIN EN 61000 -4-6:2014 -08; DIN EN 61000 -4-8:2010 -11; DIN EN 61000 -4-9:2017 -05; DIN EN 61000 -4-10:2001 -12; DIN EN 61000 -4-11:2005 -02
IEC 61000-4-10Name not checked yet
DIN EN 61000 -4-6:2014 -08; DIN EN 61000 -4-8:2010 -11; DIN EN 61000 -4-9:2017 -05; DIN EN 61000 -4-10:2001 -12; DIN EN 61000 -4-11:2005 -02
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
DIN EN 61000 -4-6:2014 -08; DIN EN 61000 -4-8:2010 -11; DIN EN 61000 -4-9:2017 -05; DIN EN 61000 -4-10:2001 -12; DIN EN 61000 -4-11:2005 -02
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
DIN EN 61000 -4-13:2016 -10; DIN EN 61000 -4-16:2016 -10; DIN EN 61000 -4-17:2005 -04; DIN EN 61000-4-17/A2: 2009-11; DIN EN 61000 -4-18:2007 -12; DIN EN 61000-4-18/A1: 2011-
IEC 61000-4-16Name not checked yet
DIN EN 61000 -4-13:2016 -10; DIN EN 61000 -4-16:2016 -10; DIN EN 61000 -4-17:2005 -04; DIN EN 61000-4-17/A2: 2009-11; DIN EN 61000 -4-18:2007 -12; DIN EN 61000-4-18/A1: 2011-
IEC 61000-4-17Name not checked yet
DIN EN 61000 -4-13:2016 -10; DIN EN 61000 -4-16:2016 -10; DIN EN 61000 -4-17:2005 -04; DIN EN 61000-4-17/A2: 2009-11; DIN EN 61000 -4-18:2007 -12; DIN EN 61000-4-18/A1: 2011-
IEC 61000-4-18Name not checked yet
DIN EN 61000 -4-13:2016 -10; DIN EN 61000 -4-16:2016 -10; DIN EN 61000 -4-17:2005 -04; DIN EN 61000-4-17/A2: 2009-11; DIN EN 61000 -4-18:2007 -12; DIN EN 61000-4-18/A1: 2011-
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
DIN EN 61000 -4-29:2001 -10; DIN EN 61000 -4-39; DIN EN 61000 -6-1:2007 -10; DIN EN 61000 -6-2:2006 -03; DIN EN 61000-6-2 Berichtigung 1:2011-06; DIN EN 61000 -6-3:2011 -09; DIN EN 61000-6-3 Berichtigung 1:2012-11
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
DIN EN 61000 -4-29:2001 -10; DIN EN 61000 -4-39; DIN EN 61000 -6-1:2007 -10; DIN EN 61000 -6-2:2006 -03; DIN EN 61000-6-2 Berichtigung 1:2011-06; DIN EN 61000 -6-3:2011 -09; DIN EN 61000-6-3 Berichtigung 1:2012-11
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
DIN EN 61000 -4-29:2001 -10; DIN EN 61000 -4-39; DIN EN 61000 -6-1:2007 -10; DIN EN 61000 -6-2:2006 -03; DIN EN 61000-6-2 Berichtigung 1:2011-06; DIN EN 61000 -6-3:2011 -09; DIN EN 61000-6-3 Berichtigung 1:2012-11
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
DIN EN 61000 -4-29:2001 -10; DIN EN 61000 -4-39; DIN EN 61000 -6-1:2007 -10; DIN EN 61000 -6-2:2006 -03; DIN EN 61000-6-2 Berichtigung 1:2011-06; DIN EN 61000 -6-3:2011 -09; DIN EN 61000-6-3 Berichtigung 1:2012-11
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
DIN EN 61000 -4-29:2001 -10; DIN EN 61000 -4-39; DIN EN 61000 -6-1:2007 -10; DIN EN 61000 -6-2:2006 -03; DIN EN 61000-6-2 Berichtigung 1:2011-06; DIN EN 61000 -6-3:2011 -09; DIN EN 61000-6-3 Berichtigung 1:2012-11
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
DIN EN 61000-6-4:2011-09; DIN EN 61000-6-5:2016-07; DIN EN 61000-6-7:2015; DIN EN IEC 61000-6-8:2022-02; DIN EN 298:2012-11
IEC 61000-6-5Name not checked yet
DIN EN 61000-6-4:2011-09; DIN EN 61000-6-5:2016-07; DIN EN 61000-6-7:2015; DIN EN IEC 61000-6-8:2022-02; DIN EN 298:2012-11
IEC 61000-6-7Name not checked yet
DIN EN 61000-6-4:2011-09; DIN EN 61000-6-5:2016-07; DIN EN 61000-6-7:2015; DIN EN IEC 61000-6-8:2022-02; DIN EN 298:2012-11
IEC 61000-6-8Name not checked yet
DIN EN 61000-6-4:2011-09; DIN EN 61000-6-5:2016-07; DIN EN 61000-6-7:2015; DIN EN IEC 61000-6-8:2022-02; DIN EN 298:2012-11
IEC
IEC 60204-31Name not checked yet
DIN EN 55103 -1:2013 -11; DIN EN 55103 -2:2010 -07; DIN EN 60204 -31:2014 -03; DIN EN 60335 -1:2012 -10; DIN EN 60669 -2-5:2017 -05
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements
DIN EN 55103 -1:2013 -11; DIN EN 55103 -2:2010 -07; DIN EN 60204 -31:2014 -03; DIN EN 60335 -1:2012 -10; DIN EN 60669 -2-5:2017 -05
IEC 60669-2-5Name not checked yet
DIN EN 55103 -1:2013 -11; DIN EN 55103 -2:2010 -07; DIN EN 60204 -31:2014 -03; DIN EN 60335 -1:2012 -10; DIN EN 60669 -2-5:2017 -05
IEC 60730-1Automatic electrical controls - Part 1: General requirements
DIN EN 60730 -1:2017 -05; DIN EN 60870 -2-1:1997 -07; DIN EN 60945:2003 -07; DIN EN 60947 -1:2015 -09; DIN EN 60947 -4-1:2014 -02; DIN EN 61131 -2:2008 -04; DIN EN 61800 -3:2012 -09
IEC 60870-2-1Name not checked yet
DIN EN 60730 -1:2017 -05; DIN EN 60870 -2-1:1997 -07; DIN EN 60945:2003 -07; DIN EN 60947 -1:2015 -09; DIN EN 60947 -4-1:2014 -02; DIN EN 61131 -2:2008 -04; DIN EN 61800 -3:2012 -09
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
DIN EN 60730 -1:2017 -05; DIN EN 60870 -2-1:1997 -07; DIN EN 60945:2003 -07; DIN EN 60947 -1:2015 -09; DIN EN 60947 -4-1:2014 -02; DIN EN 61131 -2:2008 -04; DIN EN 61800 -3:2012 -09
IEC 60947-1Name not checked yet
DIN EN 60730 -1:2017 -05; DIN EN 60870 -2-1:1997 -07; DIN EN 60945:2003 -07; DIN EN 60947 -1:2015 -09; DIN EN 60947 -4-1:2014 -02; DIN EN 61131 -2:2008 -04; DIN EN 61800 -3:2012 -09
IEC 60947-4-1Name not checked yet
DIN EN 60730 -1:2017 -05; DIN EN 60870 -2-1:1997 -07; DIN EN 60945:2003 -07; DIN EN 60947 -1:2015 -09; DIN EN 60947 -4-1:2014 -02; DIN EN 61131 -2:2008 -04; DIN EN 61800 -3:2012 -09
IEC 61131-2Name not checked yet
DIN EN 60730 -1:2017 -05; DIN EN 60870 -2-1:1997 -07; DIN EN 60945:2003 -07; DIN EN 60947 -1:2015 -09; DIN EN 60947 -4-1:2014 -02; DIN EN 61131 -2:2008 -04; DIN EN 61800 -3:2012 -09
IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
DIN EN 60730 -1:2017 -05; DIN EN 60870 -2-1:1997 -07; DIN EN 60945:2003 -07; DIN EN 60947 -1:2015 -09; DIN EN 60947 -4-1:2014 -02; DIN EN 61131 -2:2008 -04; DIN EN 61800 -3:2012 -09
IEC 62026-1Name not checked yet
DIN EN 61326 -1:2013 -07; DIN EN 61326 -3-1:2008 -11; DIN EN 61326 -3-2:2008 -11; DIN EN 62026 -1:2008 -05; DIN EN 62026 -2:2015 -03; DIN EN 62052 -11: 2017 -09
IEC 62026-2Name not checked yet
DIN EN 61326 -1:2013 -07; DIN EN 61326 -3-1:2008 -11; DIN EN 61326 -3-2:2008 -11; DIN EN 62026 -1:2008 -05; DIN EN 62026 -2:2015 -03; DIN EN 62052 -11: 2017 -09
IEC 62052-11Name not checked yet
DIN EN 61326 -1:2013 -07; DIN EN 61326 -3-1:2008 -11; DIN EN 61326 -3-2:2008 -11; DIN EN 62026 -1:2008 -05; DIN EN 62026 -2:2015 -03; DIN EN 62052 -11: 2017 -09
IEC 62052-21Name not checked yet
DIN EN 62052 -21: 2017 -10; DIN EN 62053 -21:2017 -09; DIN EN 62053 -22: 2017 -09; DIN EN 62920:2018:07; DNVGL -CG -0339:2015 -11; EMV Regelung 06; OIML R 50 -2:2014
IEC 62053-21Name not checked yet
DIN EN 62052 -21: 2017 -10; DIN EN 62053 -21:2017 -09; DIN EN 62053 -22: 2017 -09; DIN EN 62920:2018:07; DNVGL -CG -0339:2015 -11; EMV Regelung 06; OIML R 50 -2:2014
IEC 62053-22Name not checked yet
DIN EN 62052 -21: 2017 -10; DIN EN 62053 -21:2017 -09; DIN EN 62053 -22: 2017 -09; DIN EN 62920:2018:07; DNVGL -CG -0339:2015 -11; EMV Regelung 06; OIML R 50 -2:2014
IEC 62920Name not checked yet
DIN EN 62052 -21: 2017 -10; DIN EN 62053 -21:2017 -09; DIN EN 62053 -22: 2017 -09; DIN EN 62920:2018:07; DNVGL -CG -0339:2015 -11; EMV Regelung 06; OIML R 50 -2:2014
EN
EN 298Name not checked yet
DIN EN 61000-6-4:2011-09; DIN EN 61000-6-5:2016-07; DIN EN 61000-6-7:2015; DIN EN IEC 61000-6-8:2022-02; DIN EN 298:2012-11
EN 13611Name not checked yet
DIN EN 13611:2016 -09; DIN EN 45501:2016 -03; OEVE/OENORM EN 50090-2-2:2008-01-01; DIN EN 50121 -2: 2017 -11; DIN EN 50121 -3-1:2017 -11; DIN EN 50121 -3-2: 2017 -11; DIN EN 50121 -4:2017 -11
EN 45501Name not checked yet
DIN EN 13611:2016 -09; DIN EN 45501:2016 -03; OEVE/OENORM EN 50090-2-2:2008-01-01; DIN EN 50121 -2: 2017 -11; DIN EN 50121 -3-1:2017 -11; DIN EN 50121 -3-2: 2017 -11; DIN EN 50121 -4:2017 -11
EN 50090-2-2Name not checked yet
DIN EN 13611:2016 -09; DIN EN 45501:2016 -03; OEVE/OENORM EN 50090-2-2:2008-01-01; DIN EN 50121 -2: 2017 -11; DIN EN 50121 -3-1:2017 -11; DIN EN 50121 -3-2: 2017 -11; DIN EN 50121 -4:2017 -11
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
DIN EN 50121 -5: 2017 -11; DIN EN 50130 -4:2015 -04; DIN EN 50155:2008 -03; DIN EN 50270:2015 -10; DIN EN 50491 -5-1:2010 -11
EN 50155Railway applications - Rolling stock - Electronic equipment
DIN EN 50121 -5: 2017 -11; DIN EN 50130 -4:2015 -04; DIN EN 50155:2008 -03; DIN EN 50270:2015 -10; DIN EN 50491 -5-1:2010 -11
EN 50270Name not checked yet
DIN EN 50121 -5: 2017 -11; DIN EN 50130 -4:2015 -04; DIN EN 50155:2008 -03; DIN EN 50270:2015 -10; DIN EN 50491 -5-1:2010 -11
EN 50500Name not checked yet
DIN EN 50491 -5-2:2010 -11; DIN EN 50491 -5-3:2010 -11; DIN EN 50500:2009 -03; DIN EN 50500/A1:2015-08; DIN EN 55011:2017 -03; DIN EN 55014 -1:2012 -05
EN 55103-1Name not checked yet
DIN EN 55103 -1:2013 -11; DIN EN 55103 -2:2010 -07; DIN EN 60204 -31:2014 -03; DIN EN 60335 -1:2012 -10; DIN EN 60669 -2-5:2017 -05
EN 55103-2Name not checked yet
DIN EN 55103 -1:2013 -11; DIN EN 55103 -2:2010 -07; DIN EN 60204 -31:2014 -03; DIN EN 60335 -1:2012 -10; DIN EN 60669 -2-5:2017 -05
CISPR
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementCertificate says EN 55011. Probably the same standard; not checked against the EN document.
DIN EN 50491 -5-2:2010 -11; DIN EN 50491 -5-3:2010 -11; DIN EN 50500:2009 -03; DIN EN 50500/A1:2015-08; DIN EN 55011:2017 -03; DIN EN 55014 -1:2012 -05
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionCertificate says EN 55014-1. Probably the same standard; not checked against the EN document.
DIN EN 50491 -5-2:2010 -11; DIN EN 50491 -5-3:2010 -11; DIN EN 50500:2009 -03; DIN EN 50500/A1:2015-08; DIN EN 55011:2017 -03; DIN EN 55014 -1:2012 -05
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standardCertificate says EN 55014-2. Probably the same standard; not checked against the EN document.
DIN EN 55014 -2:2016 -01; DIN EN 55015:2016 -04; DIN EN 55022:2011 -12; DIN EN 55024:2016 -05; DIN EN 55032:2016 -02; DIN EN 55035 :2018 -04
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipmentCertificate says EN 55015. Probably the same standard; not checked against the EN document.
DIN EN 55014 -2:2016 -01; DIN EN 55015:2016 -04; DIN EN 55022:2011 -12; DIN EN 55024:2016 -05; DIN EN 55032:2016 -02; DIN EN 55035 :2018 -04
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurementCertificate says EN 55022. Probably the same standard; not checked against the EN document.
DIN EN 55014 -2:2016 -01; DIN EN 55015:2016 -04; DIN EN 55022:2011 -12; DIN EN 55024:2016 -05; DIN EN 55032:2016 -02; DIN EN 55035 :2018 -04
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurementCertificate says EN 55024. Probably the same standard; not checked against the EN document.
DIN EN 55014 -2:2016 -01; DIN EN 55015:2016 -04; DIN EN 55022:2011 -12; DIN EN 55024:2016 -05; DIN EN 55032:2016 -02; DIN EN 55035 :2018 -04
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsCertificate says EN 55032. Probably the same standard; not checked against the EN document.
DIN EN 55014 -2:2016 -01; DIN EN 55015:2016 -04; DIN EN 55022:2011 -12; DIN EN 55024:2016 -05; DIN EN 55032:2016 -02; DIN EN 55035 :2018 -04
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsCertificate says EN 55035. Probably the same standard; not checked against the EN document.
DIN EN 55014 -2:2016 -01; DIN EN 55015:2016 -04; DIN EN 55022:2011 -12; DIN EN 55024:2016 -05; DIN EN 55032:2016 -02; DIN EN 55035 :2018 -04
EN 50121 series
EN 50121-2Name not checked yet
DIN EN 13611:2016 -09; DIN EN 45501:2016 -03; OEVE/OENORM EN 50090-2-2:2008-01-01; DIN EN 50121 -2: 2017 -11; DIN EN 50121 -3-1:2017 -11; DIN EN 50121 -3-2: 2017 -11; DIN EN 50121 -4:2017 -11
EN 50121-3-1Name not checked yet
DIN EN 13611:2016 -09; DIN EN 45501:2016 -03; OEVE/OENORM EN 50090-2-2:2008-01-01; DIN EN 50121 -2: 2017 -11; DIN EN 50121 -3-1:2017 -11; DIN EN 50121 -3-2: 2017 -11; DIN EN 50121 -4:2017 -11
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
DIN EN 13611:2016 -09; DIN EN 45501:2016 -03; OEVE/OENORM EN 50090-2-2:2008-01-01; DIN EN 50121 -2: 2017 -11; DIN EN 50121 -3-1:2017 -11; DIN EN 50121 -3-2: 2017 -11; DIN EN 50121 -4:2017 -11
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
DIN EN 13611:2016 -09; DIN EN 45501:2016 -03; OEVE/OENORM EN 50090-2-2:2008-01-01; DIN EN 50121 -2: 2017 -11; DIN EN 50121 -3-1:2017 -11; DIN EN 50121 -3-2: 2017 -11; DIN EN 50121 -4:2017 -11
EN 50121-5Name not checked yet
DIN EN 50121 -5: 2017 -11; DIN EN 50130 -4:2015 -04; DIN EN 50155:2008 -03; DIN EN 50270:2015 -10; DIN EN 50491 -5-1:2010 -11
CISPR 16 series
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurementsCertificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.
DIN EN 55016 -2-1:2014 -12; DIN EN 55016 -2-2:2011 -09; DIN EN 55016 -2-3:2014 -11; DIN EN 61000 -3-2:2015 -03; EN 61000-3-2:2014
CISPR 16-2-2Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance powerCertificate says EN 55016-2-2. Probably the same standard; not checked against the EN document.
DIN EN 55016 -2-1:2014 -12; DIN EN 55016 -2-2:2011 -09; DIN EN 55016 -2-3:2014 -11; DIN EN 61000 -3-2:2015 -03; EN 61000-3-2:2014
CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurementsCertificate says EN 55016-2-3. Probably the same standard; not checked against the EN document.
DIN EN 55016 -2-1:2014 -12; DIN EN 55016 -2-2:2011 -09; DIN EN 55016 -2-3:2014 -11; DIN EN 61000 -3-2:2015 -03; EN 61000-3-2:2014
EN 50491 series
EN 50491-5-1Name not checked yet
DIN EN 50121 -5: 2017 -11; DIN EN 50130 -4:2015 -04; DIN EN 50155:2008 -03; DIN EN 50270:2015 -10; DIN EN 50491 -5-1:2010 -11
EN 50491-5-2Name not checked yet
DIN EN 50491 -5-2:2010 -11; DIN EN 50491 -5-3:2010 -11; DIN EN 50500:2009 -03; DIN EN 50500/A1:2015-08; DIN EN 55011:2017 -03; DIN EN 55014 -1:2012 -05
EN 50491-5-3Name not checked yet
DIN EN 50491 -5-2:2010 -11; DIN EN 50491 -5-3:2010 -11; DIN EN 50500:2009 -03; DIN EN 50500/A1:2015-08; DIN EN 55011:2017 -03; DIN EN 55014 -1:2012 -05
IEC 61326 series
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
DIN EN 61326 -1:2013 -07; DIN EN 61326 -3-1:2008 -11; DIN EN 61326 -3-2:2008 -11; DIN EN 62026 -1:2008 -05; DIN EN 62026 -2:2015 -03; DIN EN 62052 -11: 2017 -09
IEC 61326-3-1Name not checked yet
DIN EN 61326 -1:2013 -07; DIN EN 61326 -3-1:2008 -11; DIN EN 61326 -3-2:2008 -11; DIN EN 62026 -1:2008 -05; DIN EN 62026 -2:2015 -03; DIN EN 62052 -11: 2017 -09
IEC 61326-3-2Name not checked yet
DIN EN 61326 -1:2013 -07; DIN EN 61326 -3-1:2008 -11; DIN EN 61326 -3-2:2008 -11; DIN EN 62026 -1:2008 -05; DIN EN 62026 -2:2015 -03; DIN EN 62052 -11: 2017 -09
Scope as published by DAKKS
17 lines
ISO/IEC 17025
ActiveD-PL-19334-01-01
ISO/IEC 17025
ActiveD-PL-19334-01-00
Location
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.