Registers refreshed 2026-11-20.See refresh dates
United States

Automated Precision

15000 John Hopkins Dr., 20850, Rockville, MD, United States

Visit website
A2LA 2229.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 2229.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994-to 1 mm
2sm 90-to 80 m
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2229.01) 12/19/2024 Page 3 of 4 Parameter/Equipment Range CMC2 (±) Comments Spherically Mounted Retro-Reflector (SMR) Centering Accuracy Up to 1 mm 3D Centering Up to 1 mm X-Y Centering Up to 1 mm Z-Depth Centering 0.25 µm 0.15 µm 0.20 µm Straightness sensor Spindle Analyzer Up to 0.8 mm 0.06 µm Trans. ref. laser Straightness Sensor Up to 3 mm 0.04 µm Trans. ref. laser Angle Sensor Up to 800 arc seconds 0.07 arc seconds Trans. ref. laser XD Level Reference Up to 1° 0.07 arc seconds Trans. ref. laser Swivel Check, Roto Check Angle Encoder: 360° Level Sensor: 1.5° 0.11 arc seconds 0.17 arc seconds Polygon mirror, autocollimator, angle encoder Telescoping Ballbar Up to 6 mm 0.06 µm Trans. ref. laser vProbe Pitch: 80° Yaw: 80° Roll: 360° 0.94 µm/m 0.94 µm/m 1.1 µm/m Laser tracking system, angle encoder SmartTrack Sensor Pitch: ± 55° Yaw: ± 360° Roll: ± 60° 1.5 arc seconds Polygon mirror, autocollimator, angle encoder Trans. Ref. Laser – Wavelength Distance 633 nm Up to 80 m 0.004 parts in 10 6 0.1 μm/m 1 st ref. laser, frequency counter, 1st ref. thermometer, 1st ref. pressure sensor
to 1 mm
4-Air
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2229.01) 12/19/2024 Page 4 of 4 II. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Weather Station – Temperature Air Pressure (-10 to 60) °C (375 to 825) mmHg 0.07 °C 0.1 mmHg 1 st ref. thermometer 1st ref. pressure sensor ____________________________________________ 1 Commercial calibration service is not normally available for this laboratory. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’ s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy.
See scope document
5ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

15000 John Hopkins Dr., Rockville, MD, 20850, US

39.08180, -77.15168

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.