Registers refreshed 2026-11-20.See refresh dates
Poland

Powiatowa Stacja Sanitarno-Epidemiologiczna w Pile

al. Wojska Polskiego 43, 64-920, Piła, Poland

PCA AB 616ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
22
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 22 standard numbers and the 20 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO17
ISO 6058Water quality - Determination of calcium content - EDTA titrimetric method
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 8467Water quality - Determination of permanganate index
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9308-3Water quality - Detection and enumeration of Escherichia coli and coliform bacteria - Part 3: Miniaturized method (Most Probable Number) for the detection and enumeration of E. coli in surface and waste water
ISO 9964-1Water quality - Determination of sodium and potassium - Part 1: Determination of sodium by atomic absorption spectrometry
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
Show all 17
ISO 10304-4Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.

ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
EN3
EN 1622Water quality - Determination of the threshold odour number (TON) and threshold flavour number (TFN)
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
Other standards2
C-04554-4:1999
C-04576-4:1994

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

6 lines
PCA

ISO/IEC 17025

Active

AB 616

The scope document we hold says it is valid until 2029-06-23.

View on PCA

Accredited scope, certificate AB 616

LineMethodMatrixRange
1-wody, wody do spożycia przez ludzi; obiektów i materiałów biologicznych przeznaczonych do badań
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 616 Scope of accreditation No. AB 616 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 616 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa ul. Szczotkarska 42 Wydanie/Issue 26 z/of 29.05.2025 r. p.o. KIEROWNIKA DZIAŁU AKREDYTACJI BADAŃ CHEMICZNYCH MARCIN BEKAS Niniejszy dokument jest załącznikiem do Ce rtyfikatu Akredytacji Nr AB 616 z dnia 01.06.2020 r. Cykl akredytacji od 29.05.2025 r. do 23.06.2029 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 616 of 01.06.2020 Accreditation cycle from 29.05.2025 to 23.06.2029 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr/ Issue No. 26, 29.05.2025 1/7 Nazwa i adres / Name and address POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA W PILE al. Wojska Polskiego 43 64-920 Piła Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: ­ C/28; C/29 ­ K/28; K/29 ­ K/3 ­ N/28; N/29 ­ Q/29 ­ Badania chemiczne wody, wody do spożycia przez ludzi / Chemical tests of water, drinking water ­ Badania mikrobiologiczne wody, wody do spożycia przez ludzi / Microbiological tests of water, drinking water ­ Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań / Microbiological tests of biological items and materials for testing ­ Badania właściwości fizycznych wody, wody do spożycia przez ludzi / Tests of physical properties of water, drinking water ­ Badania sensoryczne wody do spożycia przez ludzi / Sensory tests of drinking water Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 616
-
2PN-ISO 6332:2001; PN-ISO 6332:2001/Ap1:2016-06; PN-EN 26777:1999; PN-82/C-04576.08; PN-C-04576-4:1994; W/PB-36 wyd. 2 z 21.07.2023 r.; PN-EN ISO 10523:2012; PN-EN 27888:1999; PN-EN ISO 7887:2012 Metoda D; PN-EN ISO 7887:2012/Ap1:2015-06; PN-EN ISO 7887:2012 Metoda C; PN-ISO 6059:1999; PN-ISO 6058:1999; PN-C-04554-4:1999; PN-EN ISO 7027-1:2016-09; PN-78/C-04588.03; PN-80/C-04617.04; PN-EN ISO 8467:2001Drinking waterSee scope document
3PN-ISO 9964-1:1994; PN-ISO 9964-1:1994/Ap1:2009; PN-79/C-04566.10; PN-92/C-04570/01; PN-EN ISO 10304-1:2009; PN-EN ISO 10304-1:2009/AC:2012; PN-EN ISO 10304-4:2022-08Drinking waterSee scope document
4PN-EN 1622:2006; PN-82/C-04576.08; PN-EN ISO 7027-1:2016-09; PN-EN ISO 8467:2001; PN-EN ISO 10304-1:2009; PN-EN ISO 10304-1:2009/AC:2012Drinking waterSee scope document
5PN-EN ISO 9308-3:2002; PN-EN ISO 7899-2:2004; PN-EN ISO 9308-1:2014-12; PN-EN ISO 9308-1:2014-12 /A1:2017-04; PN-EN ISO 6222:2004; PN-EN ISO 11731:2017-08; PN-EN ISO 11731:2017-08 /Ap1:2019-12; PN-EN ISO 14189:2016-10; PN-EN ISO 16266:2009Drinking water-
6-Materiał biologiczny ludzki (kał, wymaz z odbytu); Biologiczne wskaźniki kontroli skuteczności sterylizacji
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 616 Wydanie nr 26, 29.05.2025 r. 6/7 Oddział Laboratoryjny Laboratorium Mikrobiologii al. Wojska Polskiego 43, 64-920 Piła Przedmiot badań/wyrób Rodzaj działalności/badane cechy/metoda Dokumenty odniesienia Materiał biologiczny ludzki (kał, wymaz z odbytu) Obecność i identyfikacja pałeczek Salmonella, Shigella Metoda hodowlana, uzupełniona testami biochemicznymi i serologicznymi M/PB-01 wyd. 6 z dnia 21.07.2023 r. Biologiczne wskaźniki kontroli skuteczności sterylizacji Obecność drobnoustroju wskaźnikowego (Geobacillus stearothermophillus) Metoda hodowlana M/PB-02 wyd. 4 z dnia 21.07.2023 r. Wersja strony: A
-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.