Vulcan Electric Company, Corporation
28 Endfield Street, 04068, Porter, ME, United States
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 4974.01 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4974.01) Revised 10/13/2025 Page 1 of 5
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
VULCAN ELECTRIC COMPANY, CORPORATION
28 Endfield Street
Porter, ME 04068
Thaddeus Ver Wey Phone: 207 625 3231
CALIBRATION
Valid To: September 30, 2026 Certificate Number: 4974.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory to perform the following calibrations1, 3:
I. Thermodynamics
Parameter/Equipment
Range
CMC2 (±)
Comments
Thermodynamic,
Thermocouple
Calibration, Type B
(250 to 1200) °C
(100 to 649) °C
(650 to 1100) °C
(1100 to 1295) °C
0.75 °C
2.3 °C
1.2 °C
1.5 °C
Comparison method
in electric tube
furnace
Comparison method
in fluidized bed
furnace
Thermodynamic,
Thermocouple
Calibration, Type C
0 °C
(0 to 50) °C
(50 to 250) °C
(38 to 1200) °C
0.82 °C
0.82 °C
0.75 °C
0.49 °C
Comparison method
in ice bath
Comparison method
in stirred antifreeze
bath
Comparison method
in stirred oil bath
Comparison method
in electric tube
furnace | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4974.01) Revised 10/13/2025 Page 2 of 5
Parameter/Equipment
Range
CMC2 (±)
Comments
Thermodynamic,
Thermocouple
Calibration, Type E
-196 °C
(-70 to 25) °C
0 °C
(0 to 50) °C
(50 to 250) °C
(38 to 1000) °C
0.33 °C
0.21 °C
0.22 °C
0.28 °C
0.20 °C
0.63 °C
Comparison method
in stirred liquid
nitrogen bath
Comparison method
in stirred methanol
bath
Comparison method
in ice bath
Comparison method
in stirred antifreeze
bath
Comparison method
in stirred oil bath
Comparison method
in electric tube
furnace
Thermodynamic,
Thermocouple
Calibration, Type J
0 °C
(0 to 50) °C
(50 to 250) °C
(38 to 1200) °C
0.22 °C
0.28 °C
0.20 °C
0.63 °C
Comparison method
in ice bath
Comparison method
in stirred antifreeze
bath
Comparison method
in stirred oil bath
Comparison method
in electric tube
furnace
Thermodynamic,
Thermocouple
Calibration, Type K
-196 °C
(-70 to 25) °C
0 °C
0.35 °C
0.21 °C
0.23 °C
Comparison method
in stirred liquid
nitrogen bath
Comparison method
in stirred methanol
bath
Comparison method
in ice bath | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4974.01) Revised 10/13/2025 Page 3 of 5
Parameter/Equipment
Range
CMC2 (±)
Comments
Thermodynamic,
Thermocouple
Calibration, Type K
(cont)
(0 to 50) °C
(50 to 250) °C
(38 to 1200) °C
0.28 °C
0.21 °C
0.62 °C
Comparison method
in stirred antifreeze
bath
Comparison method
in stirred oil bath
Comparison method
in electric tube
furnace
Thermodynamic,
Thermocouple
Calibration, Type N
0 °C
(0 to 50) °C
(50 to 250) °C
(38 to 1200) °C
0.24 °C
0.29 °C
0.22 °C
0.62 °C
Comparison method
in ice bath
Comparison method
in stirred antifreeze
bath
Comparison method
in stirred oil bath
Comparison method
in electric tube
furnace
Thermodynamic,
Thermocouple
Calibration, Type P
(Platinel II)
0 °C
(0 to 50) °C
(50 to 250) °C
(38 to 1200) °C
0.28 °C
0.34 °C
0.25 °C
0.75 °C
Comparison method
in ice bath
Comparison method
in stirred antifreeze
bath
Comparison method
in stirred oil bath
Comparison method
in electric tube
furnace | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4974.01) Revised 10/13/2025 Page 4 of 5
Parameter/Equipment
Range
CMC2 (±)
Comments
Thermodynamic,
Thermocouple
Calibration, Type R
0 °C
(0 to 50) °C
(50 to 250) °C
(38 to 1200) °C
(100 to 649) °C
(650 to 1100) °C
(1100 to 1295) °C
0.55 °C
0.50 °C
0.41 °C
0.64 °C
2.4 °C
1.3 °C
1.6 °C
Comparison method
in ice bath
Comparison method
in stirred antifreeze
bath
Comparison method
in stirred oil bath
Comparison method
in electric tube
furnace
Comparison method
in fluidized bed
furnace
Thermodynamic,
Thermocouple
Calibration, Type S
0 °C
(0 to 50) °C
(50 to 250) °C
(38 to 1200) °C
(100 to 649) °C
(650 to 1100) °C
(1100 to 1295) °C
0.53 °C
0.50 °C
0.41 °C
0.63 °C
2.3 °C
1.2 °C
1.5 °C
Comparison method
in ice bath
Comparison method
in stirred antifreeze
bath
Comparison method
in stirred oil bath
Comparison method
in electric tube
furnace
Comparison method
in fluidized bed
furnace
Thermodynamic,
Thermocouple
Calibration, Type T
-196 °C
-70 to 25 °C
0 °C
0.35 °C
0.21 °C
0.23 °C
Comparison method
in stirred liquid
nitrogen bath
Comparison method
in stirred methanol
bath
Comparison method
in ice bath | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4974.01) Revised 10/13/2025 Page 5 of 5
Parameter/Equipment
Range
CMC2 (±)
Comments
Thermodynamic,
Thermocouple
Calibration, Type T
(cont)
(0 to 50) °C
(50 to 250) °C
(38 to 400) °C
0.28 °C
0.20 °C
0.63 °C
Comparison method
in stirred antifreeze
bath
Comparison method
in stirred oil bath
Comparison method
in electric tube
furnace
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 6 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.