ITH Engineering
5000 Prime Parkway, 60050, McHenry, IL, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 4151.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4151.01) Revised 03/21/2025 Page 1 of 4
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
ITH ENGINEERING INC.
5000 Prime Parkway
McHenry, IL 60050
Dean Arnoldussen Phone: 815 363 4900
CALIBRATION
Valid To: January 31, 2027 Certificate Number: 4151.01
In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory at the location above as well as the three satellite laboratories listed below to
perform the following calibrations
1, 4:
I. Mechanical
Parameter/Equipment
Range
CMC
2, 5 (±)
Comments
Pressure – Measure3
(0 to 60 000) psi
(0 to 4136) bar
(0 to 36 000) psi
(0 to 2500) bar
3.4 bar
2.7 bar
Additel model ADT681
digital pressure gauge
Additel model ADT681A
digital pressure gauge | 0 to 60000 psi |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4151.01) Revised 03/21/2025 Page 2 of 4
SATELLITE LABORATORY
ITH ENGINEERING INC.
6815 Shiloh Road East, Suite A3
Alpharetta, GA 30005
Dean Arnoldussen Phone: 815 363 4900
I. Mechanical
Parameter/Equipment
Range
CMC
2, 5 (±)
Comments
Pressure – Measure
3
(0 to 60 000) psi
(0 to 4136) bar
(0 to 36 000) psi
(0 to 2500) bar
3.4 bar
2.7 bar
Additel model ADT681
digital pressure gauge
Additel model
ADT681A digital
pressure gauge | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4151.01) Revised 03/21/2025 Page 3 of 4
SATELLITE LABORATORY
ITH ENGINEERING INC.
1650 B Dickinson Ave.
Dickinson, TX 77539
Dean Arnoldussen Phone: 815 363 4900
I. Mechanical
Parameter/Equipment
Range
CMC
2, 5 (±)
Comments
Pressure – Measure
3
(0 to 60 000) psi
(0 to 4136) bar
(0 to 36 000) psi
(0 to 2500) bar
3.4 bar
2.7 bar
Additel model ADT681
digital pressure gauge
Additel model
ADT681A digital
pressure gauge | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4151.01) Revised 03/21/2025 Page 4 of 4
SATELLITE LABORATORY
ITH ENGINEERING INC.
C. Paseo del Poeta #36A
Fracc. Jardines de Ramon Lopez Velarde
Jerez, Zacatecas 99300
MEXICO
Dean Arnoldussen Phone: 815 363 4900
I. Mechanical
Parameter/Equipment
Range
CMC
2, 5 (±)
Comments
Pressure – Measure
3
(0 to 60 000) psi
(0 to 4136) bar
(0 to 36 000) psi
(0 to 2500) bar
3.4 bar
2.7 bar
Additel model ADT681
digital pressure gauge
Additel model
ADT681A digital
pressure gauge
_______________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3
Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrate d is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter | 0 to 60000 psi |
| 5 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.