CROSS TECHNOLOGIES, INC. - WINSTON-SALEM

R J Reynolds, 950 Reynolds Blvd, 27102, Winston-Salem, NC, United States

Visit website
A2LA 1741.07ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 1741.07 · 5 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.07) 05/02/2025 Page 1 of 4 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 CROSS TECHNOLOGIES, INC 950 Reynolds Blvd., Bldg. 611-2 Winston-Salem, NC 27102 Connie Foster Phone: 800 327 7727 CALIBRATION Valid To: April 30, 2027 Certificate Number: 1741.07 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s - R025 Calibration Program Requirements), accreditation is granted to this laboratory at the location listed above perform the following calibrations 1, 8: I. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Hand Tools – Calipers & Micrometers3 Up to 8 in (4.4 + 9.1L) µin + 0.6R Gage blocks Cylindrical Sizing Standards – Circumference Diameter Up to 80 mm Up to 25.4 mm 0.0033 mm 0.0011 mm Beta lasermic, size standard Cylindrical Measuring Equipment3 – Circumference Up to 30 mm 0.027 mm Size standards
to 8 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.07) 05/02/2025 Page 2 of 4 II. Dimensional Testing/Calibration1 Parameter/Equipment Range CMC2 (±) Comments One Dimensional – Length3, 5 Up to 8 in 0.0013 in (0.033 mm) Digital calipers III. Mechanical Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments Scales & Balances3 Up to 500 mg Up to 5 g Up to 10 g Up to 20 g Up to 50 g Up to 100 g Up to 200 g Up to 500 g Up to 1000 g Up to 2000 g Up to 4000 g Up to 5000 g Up to 15 000 g 0.0062 mg + 0.6R 0.021 mg + 0.6R 0.031 mg + 0.6R 0.046 mg + 0.6R 0.074 mg + 0.6R 0.16 mg + 0.6R 0.31 mg + 0.6R 0.75 mg + 0.6R 1.6 mg + 0.6R 3.1 mg + 0.6R 6.1 mg + 0.6R 7.4 mg + 0.6R 38 mg + 0.6R Ultra-class weights Class 1 Force – Measuring Equipment3 Up to 46 kg 0.033 % Ultra-class weights Pressure Drop3 Up to 1000 mm∙H2O 0.48 % Manometers & Brooks volumeter Non-Contact RPM3 (5 to 20 000) RPM 0.024 % Tachometer Cigarette Measuring Equipment3 – Ventilation Pressure Drop Up to 90 % 50 mm·H 2O 100 mm·H2O 200 mm∙H2O 400 mm∙H2O 0.50 % 1.2 mm·H 2O 1.5 mm·H2O 2.2 mm∙H2O 3.5 mm∙H2O Glass capillary ventilation standards Glass capillary pressure drop standards
to 8 in
3Gravimetric method-See scope document
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.07) 05/02/2025 Page 4 of 4 V. Time & Frequency Parameter/Equipment Range CMC2, 7 (±) Comments Time Interval – Measure3 Up to 30 min Up to 3 hr 0.27 sec 2.5 sec Stopwatch ______________________________________________ 1 This laboratory is available for commercial and field dimensional testing/calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches and R is the numerical value of the resolution of the device. 5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration certificate. 6 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 This scope meets A2LA’s P112 Flexible Scope Policy.
to 30 min
5ISO/IEC 17025:20 17; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

R J Reynolds, 950 Reynolds Blvd, Winston-Salem, NC, 27102, US