CROSS TECHNOLOGIES, INC. - WINSTON-SALEM
R J Reynolds, 950 Reynolds Blvd, 27102, Winston-Salem, NC, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 1741.07 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.07) 05/02/2025 Page 1 of 4
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
CROSS TECHNOLOGIES, INC
950 Reynolds Blvd., Bldg. 611-2
Winston-Salem, NC 27102
Connie Foster Phone: 800 327 7727
CALIBRATION
Valid To: April 30, 2027 Certificate Number: 1741.07
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s - R025 Calibration Program Requirements), accreditation is
granted to this laboratory at the location listed above perform the following calibrations
1, 8:
I. Dimensional
Parameter/Equipment
Range CMC2, 4 (±) Comments
Hand Tools – Calipers &
Micrometers3
Up to 8 in
(4.4 + 9.1L) µin + 0.6R
Gage blocks
Cylindrical Sizing
Standards –
Circumference
Diameter
Up to 80 mm
Up to 25.4 mm
0.0033 mm
0.0011 mm
Beta lasermic, size
standard
Cylindrical Measuring
Equipment3 –
Circumference
Up to 30 mm
0.027 mm
Size standards | to 8 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.07) 05/02/2025 Page 2 of 4
II. Dimensional Testing/Calibration1
Parameter/Equipment
Range CMC2 (±) Comments
One Dimensional –
Length3, 5
Up to 8 in
0.0013 in (0.033 mm)
Digital calipers
III. Mechanical
Parameter/Equipment
Range CMC2, 4, 6, 7 (±) Comments
Scales & Balances3
Up to 500 mg
Up to 5 g
Up to 10 g
Up to 20 g
Up to 50 g
Up to 100 g
Up to 200 g
Up to 500 g
Up to 1000 g
Up to 2000 g
Up to 4000 g
Up to 5000 g
Up to 15 000 g
0.0062 mg + 0.6R
0.021 mg + 0.6R
0.031 mg + 0.6R
0.046 mg + 0.6R
0.074 mg + 0.6R
0.16 mg + 0.6R
0.31 mg + 0.6R
0.75 mg + 0.6R
1.6 mg + 0.6R
3.1 mg + 0.6R
6.1 mg + 0.6R
7.4 mg + 0.6R
38 mg + 0.6R
Ultra-class weights
Class 1
Force – Measuring
Equipment3
Up to 46 kg
0.033 %
Ultra-class weights
Pressure Drop3
Up to 1000 mm∙H2O
0.48 %
Manometers &
Brooks volumeter
Non-Contact RPM3
(5 to 20 000) RPM
0.024 %
Tachometer
Cigarette Measuring
Equipment3 –
Ventilation
Pressure Drop
Up to 90 %
50 mm·H
2O
100 mm·H2O
200 mm∙H2O
400 mm∙H2O
0.50 %
1.2 mm·H
2O
1.5 mm·H2O
2.2 mm∙H2O
3.5 mm∙H2O
Glass capillary
ventilation standards
Glass capillary
pressure drop
standards | to 8 in |
| 3 | Gravimetric method | - | See scope document |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.07) 05/02/2025 Page 4 of 4
V. Time & Frequency
Parameter/Equipment
Range CMC2, 7 (±) Comments
Time Interval – Measure3
Up to 30 min
Up to 3 hr
0.27 sec
2.5 sec
Stopwatch
______________________________________________
1 This laboratory is available for commercial and field dimensional testing/calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for these calibrations. Please note the actual measurement
uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found
on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of
calibration and for other possible adverse effects such as those caused by transportation of the calibration
equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g.
resolution) must also be considered and this, on its own, could result in the actual measurement
uncertainty achievable on a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches
and R is the numerical value of the resolution of the device.
5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration certificate.
6 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 This scope meets A2LA’s P112 Flexible Scope Policy. | to 30 min |
| 5 | ISO/IEC 17025:20 17; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.