EOLIA
ZI ATHELIA III 179 VC VOIE ATLAS, 13600, LA CIOTAT, France
- Accredited standards
- 8
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 12469
ISO 5Photography - Determination of diffuse transmission density
ISO 5-3Photography and graphic technology - Density measurements - Part 3: Spectral conditions
ISO 14644-1Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration
ISO 14644-3Cleanrooms and associated controlled environments - Part 3: Test methods
ISO 14644-7Cleanrooms and associated controlled environments - Part 7: Separative devices (clean air hoods, gloveboxes, isolators and mini-environments)
NF S90-351
NF X44-201
NF EN ISO 14644-1; NF EN ISO 14644-3; BPF 2024; BPP 2023; BPAMP 2023; BPTC 2010; NF X 44-201 (Octobre 1984); NF EN 12469
NF EN ISO 14644-1; NF EN 12469; NF EN ISO 14644-3; NF EN ISO 14644-7
ISO 5; NF S 90-351; NF EN ISO 14644-1; NF EN ISO 14644-3
NF EN ISO 14644-1; NF EN ISO 14644-3
Read from the COFRAC scope document we downloaded on 2026-09-25. Register refreshed 2026-11-06.
Scope as published by COFRAC
8 lines
ISO/IEC 17025
Active1-2416
The scope document we hold says it is valid until 2031-03-31.
Accredited scope, certificate 1-2416
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NF EN ISO/IEC 17025 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. Convention N° 3559
LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 2/8
Date de prise d’effet / Valid from : 29/04/2026
Date de fin de validité / Valid until : 31/03/2031
Pour le Directeur Général et par délégation
On behalf of the General Director
Le Responsable du Pôle Physique-Mécanique,
Pole manager - Physics-Mechanics,
Stéphane RICHARD
La présente attestation n’est valide qu’accompagnée de l’annexe technique.
This certificate is only valid if associated with the technical appendix.
L’accréditation peut être suspendue, modifiée ou retirée à tout moment. Pour une utilisation appropriée, la portée de
l’accréditation et sa validité doivent être vérifiées sur le site internet du Cofrac (www.cofrac.fr).
The accreditation can be suspended, modified or withdrawn at any time. For a proper use, the scope of accreditation and its
validity should be checked on the Cofrac website (www.cofrac.fr).
Cette attestation annule et remplace l’attestation N° 1-2416 Rév 12.
This certificate cancels and replaces the certificate N° 1-2416 Rév 12.
Seul le texte en français peut engager la responsabilité du Cofrac.
The Cofrac's liability applies only to the french text.
Comité Français d’Accréditation - 52, rue Jacques Hillairet 75012 PARIS
Tél. : +33 (0)1 44 68 82 20 – Fax : 33 (0)1 44 68 82 21 Siret : 397 879 487 00031 www.cofrac.fr | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 3/8
Section Laboratoires
ANNEXE TECHNIQUE
à l’attestation N° 1-2416 rév. 13
L’accréditation concerne les prestations réalisées par :
EOLIA
ZI ATHELIA III
179 VC VOIE ATLAS
13600 LA CIOTAT
Dans son unité technique :
- EOLIA
Elle porte sur :
voir pages suivantes | ||
| 4 | NF EN ISO 14644-1; NF EN ISO 14644-3 | Salles propres et environnements maîtrisés et apparentés | - |
| 5 | ISO 5; NF S 90-351; NF EN ISO 14644-1; NF EN ISO 14644-3 | cleanrooms and controlled environments | - |
| 6 | NF EN ISO 14644-1; NF EN ISO 14644-3; BPF 2024; BPP 2023; BPAMP 2023; BPTC 2010; NF X 44-201 (Octobre 1984); NF EN 12469 | Poste de Sécurité Microbiologique PSM type 2 | See scope document |
| 7 | NF EN ISO 14644-1; NF EN ISO 14644-3 | Hotte à flux laminaire | 0.001 to 100 % |
| 8 | NF EN ISO 14644-1; NF EN 12469; NF EN ISO 14644-3; NF EN ISO 14644-7 | Enceinte blindée; Isolateur- PSM de type 3 | 0.001 to 100 % |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.