Registers refreshed 2026-11-08.See refresh dates
France

EOLIA

ZI ATHELIA III 179 VC VOIE ATLAS, 13600, LA CIOTAT, France

COFRAC 1-2416ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
8
COFRAC certificate
1
Site in our directory
1
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 8 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 12469
ISO 5Photography - Determination of diffuse transmission density
ISO 5-3Photography and graphic technology - Density measurements - Part 3: Spectral conditions
ISO 14644-1Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration
ISO 14644-3Cleanrooms and associated controlled environments - Part 3: Test methods
ISO 14644-7Cleanrooms and associated controlled environments - Part 7: Separative devices (clean air hoods, gloveboxes, isolators and mini-environments)
NF S90-351
NF X44-201

Read from the COFRAC scope document we downloaded on 2026-09-25. Register refreshed 2026-11-06.

Scope as published by COFRAC

8 lines
COFRAC

ISO/IEC 17025

Active

1-2416

The scope document we hold says it is valid until 2031-03-31.

View scope

Accredited scope, certificate 1-2416

LineMethodMatrixRange
1NF EN ISO/IEC 17025--
2

Extracted from the scope document; tables may not line up. View scope for the original.

Convention N° 3559 LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 2/8 Date de prise d’effet / Valid from : 29/04/2026 Date de fin de validité / Valid until : 31/03/2031 Pour le Directeur Général et par délégation On behalf of the General Director Le Responsable du Pôle Physique-Mécanique, Pole manager - Physics-Mechanics, Stéphane RICHARD La présente attestation n’est valide qu’accompagnée de l’annexe technique. This certificate is only valid if associated with the technical appendix. L’accréditation peut être suspendue, modifiée ou retirée à tout moment. Pour une utilisation appropriée, la portée de l’accréditation et sa validité doivent être vérifiées sur le site internet du Cofrac (www.cofrac.fr). The accreditation can be suspended, modified or withdrawn at any time. For a proper use, the scope of accreditation and its validity should be checked on the Cofrac website (www.cofrac.fr). Cette attestation annule et remplace l’attestation N° 1-2416 Rév 12. This certificate cancels and replaces the certificate N° 1-2416 Rév 12. Seul le texte en français peut engager la responsabilité du Cofrac. The Cofrac's liability applies only to the french text. Comité Français d’Accréditation - 52, rue Jacques Hillairet 75012 PARIS Tél. : +33 (0)1 44 68 82 20 – Fax : 33 (0)1 44 68 82 21 Siret : 397 879 487 00031 www.cofrac.fr
3

Extracted from the scope document; tables may not line up. View scope for the original.

LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 3/8 Section Laboratoires ANNEXE TECHNIQUE à l’attestation N° 1-2416 rév. 13 L’accréditation concerne les prestations réalisées par : EOLIA ZI ATHELIA III 179 VC VOIE ATLAS 13600 LA CIOTAT Dans son unité technique : - EOLIA Elle porte sur : voir pages suivantes
4NF EN ISO 14644-1; NF EN ISO 14644-3Salles propres et environnements maîtrisés et apparentés-
5ISO 5; NF S 90-351; NF EN ISO 14644-1; NF EN ISO 14644-3cleanrooms and controlled environments-
6NF EN ISO 14644-1; NF EN ISO 14644-3; BPF 2024; BPP 2023; BPAMP 2023; BPTC 2010; NF X 44-201 (Octobre 1984); NF EN 12469Poste de Sécurité Microbiologique PSM type 2See scope document
7NF EN ISO 14644-1; NF EN ISO 14644-3Hotte à flux laminaire0.001 to 100 %
8NF EN ISO 14644-1; NF EN 12469; NF EN ISO 14644-3; NF EN ISO 14644-7Enceinte blindée; Isolateur- PSM de type 30.001 to 100 %

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ZI ATHELIA III 179 VC VOIE ATLAS, LA CIOTAT, 13600, FR

43.17586, 5.60625

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.