Registers refreshed 2026-11-20.See refresh dates
Poland

PRO NDT LAB Sp. z o.o.

Lorcin 122, 05-190, Nasielsk, Poland

Visit website
PCA AB 1487ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
9
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 9 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 13018Non-destructive testing - Visual testing - General principles
ISO 3452-1Non-destructive testing - Penetrant testing - Part 1: General principles
ISO 5579Non-destructive testing - Radiographic testing of metallic materials using film and X- or gamma rays - Basic rules
ISO 9934-1Non-destructive testing - Magnetic particle testing - Part 1: General principles
ISO 16810Non-destructive testing - Ultrasonic testing - General principles
ISO 17636-1Non-destructive testing of welds - Radiographic testing - Part 1: X- and gamma-ray techniques with film
ISO 17637Non-destructive testing of welds - Visual testing of fusion-welded joints
ISO 17638Non-destructive testing of welds - Magnetic particle testing
ISO 17640Non-destructive testing of welds - Ultrasonic testing - Techniques, testing levels, and assessment

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

2 lines
PCA

ISO/IEC 17025

Active

AB 1487

The scope document we hold says it is valid until 2030-01-06.

View on PCA

Accredited scope, certificate AB 1487

LineMethodMatrixRange
1-constr uction products and materials
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1487 Scope of accreditation No. AB 1487 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1487 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 17 z/of 08.12.2025 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ MECHANICZNYCH I FIZYCZNYCH MARIA SZAFRAN Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1487 z dnia of 23.12.2024 r. Cykl akredytacji od 08.12.2025 do 06.01.2030 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No. AB 1487 of 01.10.2024 Accreditation cycle from 08.12.2025 do 06.01.2030 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No. 17, 08.12.2025 1/3 Nazwa i adres / Name and address PRO NDT LAB SP. Z O.O. LABORATORIUM Lorcin 122 05-190 Nasielsk Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - L/8 - Badania nieniszczące wyrobów i materiałów konstrukcyjnych / Non-destructive tests of constr uction products and materials Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB-07 dostępnym na stronie internetowej www .pca.gov.pl / The identification code according to the Annex to document DAB-07, available at PCA website www.pca. gov.pl AB 1487
-
2PN-EN 13018:2016-04; PN-EN ISO 17637:2017-02; PN-EN ISO 5579:2014; PN-EN ISO 17636-1:2023-02; PN-EN ISO 16810:2014-06; PN-EN ISO 16810:2025-04; PN-EN ISO 17640:2019-01; PN-EN ISO 3452-1:2021-12; PN-EN ISO 9934-1:2017-02; PN-EN ISO 17638:2017-01Złącza spawane materiałów i wyrobów metalowych; Złącza spawane materiałów i wyrobów metalowych ferromagnetycznychSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Lorcin 122, Nasielsk, 05-190, PL

52.58675, 20.81301

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.