IngMar Medical
400 North Lexington St., Suite# LL117, 15208, Pittsburgh, PA, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 4172.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4172.01) 05/05/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
INGMAR MEDICAL, LLC
400 North Lexington Street, Suite LL117
Pittsburgh, PA 15208
Brad Whitfield Phone: 412 441 8228
CALIBRATION
Valid To: February 28, 2027 Certificate Number: 4172.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations1, 3:
I. Fluid Quantities
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Volume – Measuring
Equipment
10 mL
100 mL
1 L
0.59 mL
0.95 mL
8.3 mL
Hans Rudolph
syringes:
Model series 5520
Model series 5510
Model series 5540
II. Mechanical
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Pneumatic Pressure – Measure
Barometric
(98 to 102) kPa
0.14 kPa
Mensor barometric
pressure meter | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4172.01) 05/05/2025 Page 2 of 2
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Pneumatic Pressure – Measure
(cont)
Gage
Vacuum
(108 to 112) cm·H2O
(58 to 62) cm·H2O
(18 to 22) cm·H2O
(-38 to -42) cm·H2O
0.28 cm·H2O
0.16 cm·H2O
0.10 cm·H2O
0.089 cm·H2O
Mensor pressure
meter
Mensor pressure
meter
III. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature – Measure
0 °C
(19 to 27) °C
0.21 °C
0.18 °C
Ebro temperature
sensor model
TFX 410
___________________________________________
1 This laboratory may offer commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.