Air Hygiene International
Broken Arrow , OK, United States
Visit website- Accredited standards
- 9
- A2LA certificates
- 2
- Sites in our directory
- 4
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 9 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM D6348
ASTM D6784
ASTM D7036
EPA 3
EPA 11
EPA 19
EPA 25
EPA 30
EPA 205
EPA Methods 2, 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H; CARB Method 2; SCAQMD 2; CTM-041; EPA Methods 3A, 20; CARB Method 100; SCAQMD Method 100.1; EPA Methods 3A, 10; CARB Method 100; SCAQMD Method 100.1; EPA Methods 4, 5, 5A, 5B, 5D, 5E, 5F, 5H, 5I, 17, 201A, 202; CARB Method 4, CARB 5; SCAQMD Method 4; EPA Methods 6C, 16C, 20; CARB Method 100; SCAQMD Method 100.1; EPA Methods 7E, 20; EPA Alt-013; CARB Method 100; SCAQMD Method 100.1; EPA Methods 8A, 15A, 16A; CTM-013; NCASI 8A; EPA Methods 9, 22; EPA Method 11; EPA Methods 13B, 350.3; BAAQMD LAB-1A; EPA Method 25A; EPA Methods 26, 26A; CTM-013B, CTM 027; EPA Method 30B; EPA Methods 318, 320, 321; ASTM D6348-12
EPA Methods 5, 5A, 5B, 5D, 5E, 5F, 5H, 5I, 13A, 13B, 15A, 16A, 17, 23, 26, 26A, 29, 201A; CARB Method 5; EPA Methods 3A, 6C, 7E, 10, 16C, 20, 25A, 318, 320, and 321; ASTM 6348, 6522; CTM-022 and 030; CARB Method 100; SCAQMD Method 100.1; EPA Methods 8A (CTM-013), 11, 12, 13A, 13B, 15A, 16A, 17, 23, 26, 26A, 29, 202, 306, 308 and 316; CTM-013B; CTM-027; BAAQMD ST-1B; ASTM D6784; EPA Methods 18, TO-1, TO-2, TO-3, TO-5, TO-11, TO-12, TO-13, TO-14 and TO-15; 30B; GPA 2261; ASTM1945; EPA Methods 1, 1A; CARB Method 1; SCAQMD Method 1
ASTM D7036:2004
EPA Method 205; NCASI 98.01; CTM-022; CTM-030; ASTM 6522-00; ODEQ’s Guidance for Portable Electrochemical Analyzer Testing; Performance Specifications 1, 2, 3, 4, 4A, 4B, 5, 6, 7, 8, 8A, 11, 12A, 12B, 15, 16, 18; EPA Method 19; EPA Method 3; CARB Method 3; SCAQMD Method 3
Read from the A2LA scope documents we downloaded on 2026-08-05 and 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active3796.01
The scope document we hold says it is valid until 2027-08-31.
Accredited scope, certificate 3796.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | EPA Methods 5, 5A, 5B, 5D, 5E, 5F, 5H, 5I, 13A, 13B, 15A, 16A, 17, 23, 26, 26A, 29, 201A; CARB Method 5; EPA Methods 3A, 6C, 7E, 10, 16C, 20, 25A, 318, 320, and 321; ASTM 6348, 6522; CTM-022 and 030; CARB Method 100; SCAQMD Method 100.1; EPA Methods 8A (CTM-013), 11, 12, 13A, 13B, 15A, 16A, 17, 23, 26, 26A, 29, 202, 306, 308 and 316; CTM-013B; CTM-027; BAAQMD ST-1B; ASTM D6784; EPA Methods 18, TO-1, TO-2, TO-3, TO-5, TO-11, TO-12, TO-13, TO-14 and TO-15; 30B; GPA 2261; ASTM1945; EPA Methods 1, 1A; CARB Method 1; SCAQMD Method 1 | Air | - |
| 2 | EPA Methods 2, 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H; CARB Method 2; SCAQMD 2; CTM-041; EPA Methods 3A, 20; CARB Method 100; SCAQMD Method 100.1; EPA Methods 3A, 10; CARB Method 100; SCAQMD Method 100.1; EPA Methods 4, 5, 5A, 5B, 5D, 5E, 5F, 5H, 5I, 17, 201A, 202; CARB Method 4, CARB 5; SCAQMD Method 4; EPA Methods 6C, 16C, 20; CARB Method 100; SCAQMD Method 100.1; EPA Methods 7E, 20; EPA Alt-013; CARB Method 100; SCAQMD Method 100.1; EPA Methods 8A, 15A, 16A; CTM-013; NCASI 8A; EPA Methods 9, 22; EPA Method 11; EPA Methods 13B, 350.3; BAAQMD LAB-1A; EPA Method 25A; EPA Methods 26, 26A; CTM-013B, CTM 027; EPA Method 30B; EPA Methods 318, 320, 321; ASTM D6348-12 | - | - |
| 3 | EPA Method 205; NCASI 98.01; CTM-022; CTM-030; ASTM 6522-00; ODEQ’s Guidance for Portable Electrochemical Analyzer Testing; Performance Specifications 1, 2, 3, 4, 4A, 4B, 5, 6, 7, 8, 8A, 11, 12A, 12B, 15, 16, 18; EPA Method 19; EPA Method 3; CARB Method 3; SCAQMD Method 3 | - | - |
| 4 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active3796.02
The scope document we hold says it is valid until 2027-08-31.
Accredited scope, certificate 3796.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM D7036:2004 | Air Emission | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.