Registers refreshed 2026-11-20.See refresh dates
China

Dongguan DN Testing Co.,

No. 1, West 4th Street, Xingfa South Road, Wusha Community, Chang'an Town, Dongguan, People's Republic of China, Dongguan, China

Visit website
A2LA 7050.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
36
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 36 standard numbers and the 19 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series9
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national

National versions in the same scope

AS/NZS 61000.3.2identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national

National versions in the same scope

AS/NZS 61000.3.3identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
EN7
EN 50364
EN 50383
EN 50384
EN 50385
EN 50564
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
IEC7
IEC 62301
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)

Certificate says EN 62311. Probably the same standard; not checked against the EN document.

IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national

National versions in the same scope

AS/NZS 62368.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 62368-3
IEC 62369-1
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62493
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national

National versions in the same scope

AS CISPR 11national version with changes

AS/NZS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national

National versions in the same scope

AS CISPR 14.1national version with changes

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55014-1. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national

National versions in the same scope

AS CISPR 15national version with changes

AS/NZS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55015. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national

National versions in the same scope

AS/NZS CISPR 32identical to it

VCCI-CISPR 32probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

ETSI4
ETSI EN 301 908-13
ETSI TS 136 521-1
ETSI TS 138 521-1
ETSI TS 138 521-3
IEC 62087 series3
IEC 62087-1
IEC 62087-2
IEC 62087-7
Other standards2
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices

Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

7050.01

The scope document we hold says it is valid until 2027-07-31.

View scope

Accredited scope, certificate 7050.01

LineMethodMatrixRange
1CFR 47, FCC Part 15 Subpart B; ANSI C63.4:20142; CFR 47, FCC Part 18; MP-5:1986; CISPR 11; EN 55011; BS EN 55011; AS/NZS CISPR 11; AS CISPR 11; CISPR 14-1; EN 55014-1; BS EN 55014-1; AS/NZS CISPR 14.1; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; EN 55015; EN 55032; BS EN 55032; CISPR 32; VCCI V-3; ICES-001; ICES-003; ICES-005; VCCI CISPR 32; AS/NZS CISPR 32; AS CISPR 14.1; BETS-7; IEC 61000-6-3; IEC 61000-6-4; IEC 61000-3-2; EN 61000-3-2; BS EN 61000-3-2; AS/NZS 61000.3.2; BS EN IEC 61000-3-2; IEC 61000-3-3; EN 61000-3-3; AS/NZS 61000.3.3; BS EN 61000-3-3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6household appliances; audio and video products; lighting products; information technology products; automotive electronic products; mobile phones; computers; wireless communication products; toys and children's productsto 40 GHz
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7050.01) Revised 06/09/2026 Page 2 of 6 Test Technology: Test Method(s) 1: Power Frequency Magnetic Field Immunity IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8 Voltage Dips and Short Interrupts (Except for three -phase Equipment) IEC 61000-4-11; EN 61000-4-11; BS EN 61000-4-11; EN IEC 61000-4-11; BS EN IEC 61000-4-11 Product Family Standards and Industry Specific Standards CISPR 35; EN 55035; BS EN 55035; BS EN 61547; EN 61547; IEC 61547; EN IEC 55014-2; BS EN 55014-2; IEC 61000-6-1; IEC 61000-6-2; IEC 61326-1; IEC 60601-1-2; EN 61000-6-1; EN 61000-6-2; EN 61326-1; EN IEC 61326-2-2; EN IEC 61326-2-6; EN 60601-1-2; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-4; ETSI EN 301 489-5; ETSI EN 301 489-6; ETSI EN 301 489-9; ETSI EN 301 489-13; ETSI EN 301 489-15; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-22; ETSI EN 301 489-27; ETSI EN 301 489-28; ETSI EN 301 489-31; ETSI EN 301 489-33; ETSI EN 301 489-34; ETSI EN 301 489-35; ETSI EN 301 489-50; ETSI EN 301 489-52; ETSI EN 301 489-53 Radio Communications US/FCC CFR 47, FCC Part 15 Subpart C/E (using ANSI C63.10:2013 and ANSI C63.10-2020); FCC Part 15 Subpart E with DFS (using KDB 905462 D02 (v02)); CFR 47, FCC Parts 22, 24, 25, 27, 73, 74, 90, 95, and 97 (using ANSI/TIA-603-E); ANSI C63.26:2015; ANSI C63.4; ANSI C63.10; ANSI/TIA 603-E; TIA-102.CAAA-E Canada RSS-GEN; RSS-119; RSS-123; RSS-130; RSS-132; RSS-133; RSS-139; RSS-140; RSS-192; RSS-195; RSS-197; RSS-199; RSS-210 (< 40 GHz); RSS-236; RSS-247 (with DFS); RSS-247 (without DFS); RSS-248; RSS-310 EU (Excluding protocol conformance testing) ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 330; ETSI EN 300 422-1; ETSI EN 300 422-2; ETSI EN 300 440; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 303 687; ETSI EN 300 113; ETSI EN 300 086; ETSI EN 300 296; ETSI EN 300 219; ETSI EN 302 208; ETSI EN 302 502; ETSI EN 303 345-1; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 303 609; ETSI EN 301 511; ETSI TS 151 010-1; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI TS 134 121-1;
3ETSI EN 301 908-13; ETSI TS 136 521-1; ETSI TS 138 521-1; ETSI TS 138 521-3; AS/NZS 4268; AS/NZS 4365; AS/NZS 4295; AS/NZS 4768.1; AS/NZS 4768.2; HKCA 1020; HKCA 1039; HKCA 1042; HKCA 1048; HKCA 1046; HKCA 1034; HKCA 1043; AS/CA S042.1; AS/ACIF S042.3; AS/CA S042.4; ARIB T-33; ARIB T-66; ARIB T-71; MIC Article 2-1 Item 8; Article 2-1 Item 19; Article 2-1 Item 19-2; Article 2-1 Item 19-2-2; Article 2-1 Item 19-3; Article 2-1 Item 19-3-2; Article 2-1 Item 19-3-3; Article 49‐6‐9 the relevant articles and MIC Notice No. 338 of the Ordinance Regulating Radio Equipment; Article 49‐6‐10 the relevant articles and MIC Notice No. 247 of the Ordinance Regulating Radio Equipment; Article 49‐8‐2-3 the relevant articles and MIC Notice No. 294 of the Ordinance Regulating Radio Equipment; Article 49‐29 the relevant articles and MIC Notice No. 435 of the Ordinance Regulating Radio Equipment; Article 49‐6‐4 and 49‐6‐5 the relevant articles and MIC Notice No. 1299 of the Ordinance Regulating Radio Equipment; Article 49‐6‐13 the relevant articles and MIC Notice No. 251 of the Ordinance Regulating Radio Equipment; Article 49‐29-2 the relevant articles and MIC Notice No. 435 / No. 248 of the Ordinance Regulating Radio Equipment; Article 49‐6‐12-1 the relevant articles and MIC Notice No. 23 / No.177 of the Ordinance Regulating Radio Equipment; IEC 62368-1:2014; EN 62368-1:2014+A11:2017; BS EN 62368-1:2014+A11:2017; CSA/UL 62368-1:2014; AS/NZS 62368.1:2018; J62368-1(2020); IEC 62368-1:2018; EN 62368-1:2020+A11:2020; BS EN 62368 1:2020+A11:2020; CSA/UL 62368-1:2019; AS/NZS 62368.1:2022; KC 62368-1; IEC 62368-3:2017; EN IEC 62368-3:2020; BSEN IEC 62368-3:2020; SASO-IEC 62368-1:2020, J62368-1(2023), IEC 62368-1:2023, EN 62368-1: 2024+A11:2024, CSA C22.2 No.62368-1:19, UL 62368-1: revised October 22, 2021, BS EN 62368-1:2024+A11:2024--
4EN 62311; BS EN 62311; IEC 62311; EN IEC 62311; BS EN IEC 62311; EN 62493; BS EN 62493; IEC 62493; EN 62479; BS EN 62479; IEC 62479; EN 62369-1; BS EN 62369-1; IEC 62369-1; EN 50385; BS EN 50385; EN 50383; EN 50364; BS EN 50364; EN 50663; BS EN 50663; EN 50665; BS EN 50665; EN 50384; BS EN 50384; IEEE Std C95.3; IEC 62087-1:2015; EN 62087-1:2016; IEC 62087-2:2015; EN 62087-2:2016; IEC62087-7:2018; EN 62087-7:2019; BS EN 62087-7:2019; EN 50564; BS EN 50564; AS/NZS 5815.1:2012; AS/NZS 5815.2:2013/Amdt 1:2014; IEC/EN 62087-1; IEC/EN 62087-2; IEC/EN 62087-7; IEC 62301Audio, video, and related equipment; Information technology equipment; Computer monitors; Signage displays equipment-
5ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI C63.26-2015; ANSI/TIA-603-E; TIA-102.CAAA-E-to 40000 MHz
6ANSI C63.4a-2017; ANSI C63.4:2014--
7ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.