SICK AG Corporate Test Center
Erwin-Sick-Straße 1, 79183, Waldkirch, Germany
- Accredited standards
- 23
- DAKKS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 23 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068 series16
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-5
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
IEC 60068-2-53
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60068-2-67
IEC 60068-2-75
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 60068-2-80Environmental testing - Part 2-80: Tests - Test Fi: Vibration - Mixed mode
IEC4
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 61180
IEC 61496-1
IEC 61496-3
Other standards3
DIN 75220
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
DIN EN ISO 9227:2024-10; EN ISO 9227:2022-11 + A1:2024-06; ISO 9227:2022-11 + AMD:2024-06; ISO 20653:2023-08; DIN EN 60068-2-1:2008-01; EN 60068-2-1:2007-04; IEC 60068-2-1:2007-03; DIN EN 60068-2-2:2008-05; EN 60068-2-2:2007-09; IEC 60068-2-2:2007-07; DIN EN IEC 60068-2-5:2019-02; EN IEC 60068-2-5:2018-05; IEC 60068-2-5:2018-04; DIN EN 60068-2-6:2008-10; EN 60068-2-6:2008-2; IEC 60068-2-6:2007-12; DIN EN IEC 60068-2-11:2022-10; EN IEC 60068-2-11:2021-04; IEC 60068-2-11:2021-03; DIN EN IEC 60068-2-14:2025-03; EN IEC 60068-2-14:2023-09; IEC 60068-2-14:2023-07; DIN EN 60068-2-27:2010-02; EN 60068-2-27:2009-05; IEC 60068-2-27:2008-02; DIN EN 60068-2-30:2006-06; EN 60068-2-30:2005-12; IEC 60068-2-30:2005-08
DIN EN IEC 60068-2-38:2022-09; EN IEC 60068-2-38:2021-04; IEC 60068-2-38:2021-03; DIN EN IEC 60068-2-52:2018-08 + Bericht. 1:2019-02; EN IEC 60068-2-52:2018-02; IEC 60068-2-52:2017-11; DIN EN 60068-2-53:2011-02; EN 60068-2-53:2010-05; IEC 60068-2-53:2010-04; DIN EN 60068-2-64:2020-09; EN 60068-2-64:2008-09 + A1:2019-11; IEC 60068-2-64:2008-04 + AMD1:2019-10; DIN EN 60068-2-67:2020-08; EN 60068-2-67:1996-01 + A1:2019-08; IEC 60068-2-67:1995-12 + AMD1:2019-07; DIN EN 60068-2-75:2015-08; EN 60068-2-75:2014-10; IEC 60068-2-75:2014-09; DIN EN 60068-2-78:2014-02; EN 60068-2-78:2013-06; IEC 60068-2-78:2012-10; DIN EN 60068-2-80:2006-05; EN 60068-2-80:2005-07; IEC 60068-2-80:2005-05
DIN EN 60529:2014-09 + Berich. 1:2017-02 + Berich. 2:2019-06; EN 60529:1991-10 + A1:2000-02 +A2:2013-10 + A2/AC:2019-02; IEC 60529:1989-11 + AMD1:1999-11 + AMD2:2013-08 + AMD2-Cor1:2019-01; DIN 75220:1992-11; DIN EN 61180:2017-04; EN 61180:2016-10; IEC 61180:2016-06; DIN EN IEC 61496-1:2021-06; EN IEC 61496-1:2020-09; IEC 61496-1:2020-07; DIN EN IEC 61496-3:2019-10; EN IEC 61496-3:2019-02; IEC 61496-3:2018-12
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
4 lines
ISO/IEC 17025
ActiveD-PL-20745-02-00
Accredited scope, certificate D-PL-20745-02-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
| 2 | DIN EN ISO 9227:2024-10; EN ISO 9227:2022-11 + A1:2024-06; ISO 9227:2022-11 + AMD:2024-06; ISO 20653:2023-08; DIN EN 60068-2-1:2008-01; EN 60068-2-1:2007-04; IEC 60068-2-1:2007-03; DIN EN 60068-2-2:2008-05; EN 60068-2-2:2007-09; IEC 60068-2-2:2007-07; DIN EN IEC 60068-2-5:2019-02; EN IEC 60068-2-5:2018-05; IEC 60068-2-5:2018-04; DIN EN 60068-2-6:2008-10; EN 60068-2-6:2008-2; IEC 60068-2-6:2007-12; DIN EN IEC 60068-2-11:2022-10; EN IEC 60068-2-11:2021-04; IEC 60068-2-11:2021-03; DIN EN IEC 60068-2-14:2025-03; EN IEC 60068-2-14:2023-09; IEC 60068-2-14:2023-07; DIN EN 60068-2-27:2010-02; EN 60068-2-27:2009-05; IEC 60068-2-27:2008-02; DIN EN 60068-2-30:2006-06; EN 60068-2-30:2005-12; IEC 60068-2-30:2005-08 | - | - |
| 3 | DIN EN IEC 60068-2-38:2022-09; EN IEC 60068-2-38:2021-04; IEC 60068-2-38:2021-03; DIN EN IEC 60068-2-52:2018-08 + Bericht. 1:2019-02; EN IEC 60068-2-52:2018-02; IEC 60068-2-52:2017-11; DIN EN 60068-2-53:2011-02; EN 60068-2-53:2010-05; IEC 60068-2-53:2010-04; DIN EN 60068-2-64:2020-09; EN 60068-2-64:2008-09 + A1:2019-11; IEC 60068-2-64:2008-04 + AMD1:2019-10; DIN EN 60068-2-67:2020-08; EN 60068-2-67:1996-01 + A1:2019-08; IEC 60068-2-67:1995-12 + AMD1:2019-07; DIN EN 60068-2-75:2015-08; EN 60068-2-75:2014-10; IEC 60068-2-75:2014-09; DIN EN 60068-2-78:2014-02; EN 60068-2-78:2013-06; IEC 60068-2-78:2012-10; DIN EN 60068-2-80:2006-05; EN 60068-2-80:2005-07; IEC 60068-2-80:2005-05 | - | - |
| 4 | DIN EN 60529:2014-09 + Berich. 1:2017-02 + Berich. 2:2019-06; EN 60529:1991-10 + A1:2000-02 +A2:2013-10 + A2/AC:2019-02; IEC 60529:1989-11 + AMD1:1999-11 + AMD2:2013-08 + AMD2-Cor1:2019-01; DIN 75220:1992-11; DIN EN 61180:2017-04; EN 61180:2016-10; IEC 61180:2016-06; DIN EN IEC 61496-1:2021-06; EN IEC 61496-1:2020-09; IEC 61496-1:2020-07; DIN EN IEC 61496-3:2019-10; EN IEC 61496-3:2019-02; IEC 61496-3:2018-12 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- Eurofins GeneScanFreiburg im Breisgau · ~11 kmDAKKSShares 1 accredited test methodEN ISO 9001
- GIU Gewerbliches Institut für UmweltanalytikTeningen · ~12 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Testo Industrial ServicesKirchzarten · ~13 kmDAKKSShares 1 accredited test methodEN ISO 9001
- IFU GmbH Gewerbliches Institut für Fragen des UmweltschutzesHeitersheim · ~33 kmDAKKSShares 1 accredited test methodEN ISO 9001
- BAV Institut für Hygiene und QualitätssicherungOffenburg · ~44 kmDAKKSShares 1 accredited test methodEN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.