Registers refreshed 2026-11-08.See refresh dates
Germany

GHMT

In der Kolling 320, 66450, Bexbach, Germany

Visit website
DAKKS D-PL-17559-01-00DAKKS D-PL-17559-01-01DAKKS D-PL-17559-01-02ISO/IEC 17025Register refreshed 2026-11-06
Part of the Kiwa group: 40 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
215
DAKKS certificates
3
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 215 standard numbers and the 46 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60512 series51
IEC 60512-1-1
IEC 60512-1-2
IEC 60512-1-3
IEC 60512-1-4
IEC 60512-2-1
IEC 60512-2-2
IEC 60512-2-5
IEC 60512-3-1
IEC 60512-4-1
IEC 60512-5-1
IEC 60512-5-2
IEC 60512-6-2
Show all 51
IEC 60512-6-3
IEC 60512-6-4
IEC 60512-6-5
IEC 60512-7-1
IEC 60512-8-2
IEC 60512-8-3
IEC 60512-9-1
IEC 60512-9-2
IEC 60512-9-5
IEC 60512-10-4
IEC 60512-11-1
IEC 60512-11-3
IEC 60512-11-4
IEC 60512-11-6
IEC 60512-11-7
IEC 60512-11-9
IEC 60512-11-10
IEC 60512-11-12
IEC 60512-11-14
IEC 60512-13-1
IEC 60512-13-2
IEC 60512-13-5
IEC 60512-14-5
IEC 60512-15-6
IEC 60512-16-4
IEC 60512-16-5
IEC 60512-16-8
IEC 60512-19-3
IEC 60512-23-3
IEC 60512-23-7
IEC 60512-25-1
IEC 60512-25-2
IEC 60512-25-4
IEC 60512-25-5
IEC 60512-25-7
IEC 60512-25-9
IEC 60512-27-100
IEC 60512-28-100
IEC 60512-99-001
EN 50288 series20
EN 50288-1
EN 50288-2-1
EN 50288-2-2
EN 50288-3-1
EN 50288-3-2
EN 50288-4-1
EN 50288-4-2
EN 50288-5-1
EN 50288-5-2
EN 50288-6-1
EN 50288-6-2
EN 50288-7
Show all 20
EN 50288-8
EN 50288-9-1
EN 50288-9-2
EN 50288-10-1
EN 50288-10-2
EN 50288-11-1
EN 50288-11-2
EN 50288-12-1
EN 50289 series17
EN 50289-1-1
EN 50289-1-2
EN 50289-1-3
EN 50289-1-4
EN 50289-1-5
EN 50289-1-6
EN 50289-1-7
EN 50289-1-8
EN 50289-1-9
EN 50289-1-10
EN 50289-1-11
EN 50289-1-12
Show all 17
EN 50289-1-13
EN 50289-1-14
EN 50289-1-15
EN 50289-1-16
EN 50289-3-9
IEC 61300 series15
IEC 61300-1
IEC 61300-2-2
IEC 61300-2-4
IEC 61300-2-17
IEC 61300-2-18
IEC 61300-2-22
IEC 61300-3-3
IEC 61300-3-4
IEC 61300-3-6
IEC 61300-3-15
IEC 61300-3-16
IEC 61300-3-17
IEC 61300-3-18
IEC 61300-3-23
IEC 61300-3-34
ISO13
ISO 34-1Rubber, vulcanized or thermoplastic - Determination of tear strength - Part 1: Trouser, angle and crescent test pieces
ISO 1183-1Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pycnometer method and titration method
ISO 4091Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Definitions, tests and requirements
ISO 4141-1Road vehicles - Multi-core connecting cables - Part 1: Test methods and requirements for basic performance sheathed cables
ISO 6722-1Road vehicles - 60 V and 600 V single-core cables - Part 1: Dimensions, test methods and requirements for copper conductor cables
ISO 6722-2Road vehicles - 60 V and 600 V single-core cables - Part 2: Dimensions, test methods and requirements for aluminium conductor cables
ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperature
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 11446-2Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Part 2: 13-pole connectors for vehicles with 12 V nominal supply voltage intended to cross water fords
ISO 12098Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 15-pole connector for vehicles with 24 V nominal supply voltage
ISO 14572Road vehicles - Round, sheathed, 60 V and 600 V screened and unscreened single- or multi-core cables - Test methods and requirements for basic- and high-performance cables
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
ISO/IEC 24702Information technology - Generic cabling - Industrial premises
ISO 19642 series12
ISO 19642-1Road vehicles - Automotive cables - Part 1: Vocabulary and design guidelines
ISO 19642-2Road vehicles - Automotive cables - Part 2: Test methods
ISO 19642-3Road vehicles - Automotive cables - Part 3: Dimensions and requirements for 30 V a.c. or 60 V d.c. single core copper conductor cables
ISO 19642-4Road vehicles - Automotive cables - Part 4: Dimensions and requirements for 30 V a.c. and 60 V d.c. single core aluminium conductor cables
ISO 19642-5Road vehicles - Automotive cables - Part 5: Dimensions and requirements for 600 V a.c. or 900 V d.c. and 1 000 V a.c. or 1 500 V d.c. single core copper conductor cables
ISO 19642-6Road vehicles - Automotive cables - Part 6: Dimensions and requirements for 600 V a.c. or 900 V d.c. and 1 000 V a.c. or 1 500 V d.c. single core aluminium conductor cables
ISO 19642-7Road vehicles - Automotive cables - Part 7: Dimensions and requirements for 30 V a.c. or 60 V d.c. round, sheathed, screened or unscreened multi or single core copper conductor cables
ISO 19642-8Road vehicles - Automotive cables - Part 8: Dimensions and requirements for 30 V a.c. or 60 V d.c. round, sheathed, screened or unscreened multi or single core aluminium conductor cables
ISO 19642-9Road vehicles - Automotive cables - Part 9: Dimensions and requirements for 600 V a.c. or 900 V d.c. and 1 000 V a.c. or 1 500 V d.c. round, sheathed, screened or unscreened multi or single core copper conductor cables
ISO 19642-10Road vehicles - Automotive cables - Part 10: Dimensions and requirements for 600 V a.c. or 900 V d.c. and 1 000 V a.c. or 1 500 V d.c. round, sheathed, screened or unscreened multi or single core aluminium conductor cables
ISO 19642-11Road vehicles - Automotive cables - Part 11: Dimensions and requirements for coaxial RF cables with a specified analogue bandwidth up to 6 GHz (20 GHz)
ISO 19642-12Road vehicles - Automotive cables - Part 12: Dimensions and requirements for unscreened twisted pair RF cables with a specified analogue bandwidth up to 1 GHz
IEC 60603 series11
IEC 60603-7-1
IEC 60603-7-2
IEC 60603-7-3
IEC 60603-7-4
IEC 60603-7-5
IEC 60603-7-7
IEC 60603-7-41
IEC 60603-7-51
IEC 60603-7-71
IEC 60603-7-81
IEC 60603-7-82
IEC 61755 series11
IEC 61755-1
IEC 61755-2-1
IEC 61755-2-2
IEC 61755-3-1
IEC 61755-3-2
IEC 61755-3-3
IEC 61755-3-4
IEC 61755-3-5
IEC 61755-3-6
IEC 61755-3-7
IEC 61755-3-8
IEC 60068 series9
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-13
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-60
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 60811 series9
IEC 60811-50
IEC 60811-201
IEC 60811-202
IEC 60811-203
IEC 60811-401Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
IEC 60811-405
IEC 60811-501Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
IEC 60811-506
IEC 60811-507
IEC7
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60793-1-22
IEC 61076-3-104
IEC 61076-3-110
IEC 61196-1-116
IEC 61935-1
IEC 61935-2
IEC 62153 series7
IEC 62153-1-1
IEC 62153-4-3
IEC 62153-4-4
IEC 62153-4-5
IEC 62153-4-6
IEC 62153-4-7
IEC 62153-4-9
ISO 11801 series7
ISO/IEC 11801Information technology - Generic cabling for customer premisesSome clauses

Limits written next to it

ISO/IEC 11801 and related standard nur Kapitel 5

Some clauses. Written next to it on line 23 of DAKKS certificate D-PL-17559-01-00.

ISO/IEC 11801-1Information technology - Generic cabling for customer premises - Part 1: General requirements
ISO/IEC 11801-2Information technology - Generic cabling for customer premises - Part 2: Office premises
ISO/IEC 11801-3Information technology - Generic cabling for customer premises - Part 3: Industrial premises
ISO/IEC 11801-4Information technology - Generic cabling for customer premises - Part 4: Single-tenant homes
ISO/IEC 11801-5Information technology - Generic cabling for customer premises - Part 5: Data centres
ISO/IEC 11801-6Information technology - Generic cabling for customer premises - Part 6: Distributed building services
EN6
EN 28
EN 100
EN 1000
EN 50396
EN 50525-2-21
EN 50620
IEC 61156 series6
IEC 61156-1
IEC 61156-1-4
IEC 61156-5
IEC 61156-6
IEC 61156-9
IEC 61156-10
EN 50173 series5
EN 50173-1
EN 50173-2
EN 50173-3
EN 50173-4
EN 50173-5
ISO 16750 series4
ISO 16750-1Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 1: General
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
ISO 16750-5Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 5: Chemical loads
IEC 63171 series3
IEC 63171-1
IEC 63171-2
IEC 63171-6
Other standards2
DIN 70112
DIN 72594-2

Read from the scope as published by DAKKS. Register refreshed 2026-11-06.

Scope as published by DAKKS

95 lines
DAKKS

ISO/IEC 17025

Active

D-PL-17559-01-00

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-17559-01-01

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-17559-01-02

View scope

Location

In der Kolling 320, Bexbach, 66450, DE

49.34777, 7.24326

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.