Trescal, Inc. - Chicago, IL
718 West Algonquin Road, PO Box 559, 60005, Arlington Heights, IL, United States
Visit website- Scope lines
- 29
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 29 scope lines.
A2LA certificate 1022.03 · 29 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006 | - | to 60 ° |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 2 of 28
Parameter/Equipment Range CMC2, 5, 6 (±) Comments
Indicators3
Up to 2 in
60 µin + 7.2 µin/in
Indicator tester
Micrometers3
Spindle Linearity
Anvil Flatness
Parallelism
Up to 40 in
Up to 50 µin
Up to 50 µin
8.7 µin + 4.9 µin/in
7.3 µin
9.8 µin
Gage blocks
Optical flats
Linear Displacement3 –
Measuring Equipment
Up to 40 in
61 µin + 4.1 µin/in
Gage amplifier, gage
blocks
Plain Diameter – External
(0.003 to 0.5) in
33 µin
Laser micrometer,
master pins
Steel Tapes & Rulers3
Up to 100 ft
0.000 12 in + 0.2 µin/in
Gage blocks, jeweler’s
loupe
Length Standards
Up to 40 in
61 µin + 4.1 µin/in
Gage amplifier,
gage blocks
II. Electrical – DC/Low Frequency
Parameter/Equipment Range CMC2, 6, 7 (±) Comments
DC Voltage – Generate3
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
0.68 µV + 7 µV/V
1 µV + 6.2 µV/V
3.4 µV + 6.2 µV/V
6.4 µV + 6.2 µV/V
79 µV + 7 µV/V
0.48 mV + 9 µV/V
Fluke 5700A
w/wideband option
DC Voltage – Generate,
Fixed Points
1 V
1.018 V
10 V
4.2 µV/V
4.6 µV/V
0.68 µV/V
Fluke 732A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 3 of 28
Parameter/Equipment
Range CMC2, 4, 6, 7 (±) Comments
DC Voltage – Measure3
(0 to 1) mV
(1 to 10) mV
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
25 nV + 52 µV/V
0.41 µV + 53 µV/V
0.33 µV + 13 µV/V
0.52 µV + 4 µV/V
8.8 µV + 4 µV/V
35 µV + 8 µV/V
0.2 mV + 8 µV/V
Agilent 34420A
Agilent 3458A Opt 002
DC High Voltage3 –
Measure
(1 to 10) kV
(10 to 70) kV
0.04 %
0.044 %
Vitrek 4700
w/HVL-70
DC Current – Generate3
Clamp Meter
3
0.1 nA to 220 µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
(20 to 100) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
7.8 nA + 47 µA/A
8 nA + 46 µA/A
78 nA + 47 µA/A
0.8 µA + 62 µA/A
23 µA + 0.11 mA/A
0.38 mA + 0.28 mA/A
9.1 mA + 0.78 mA/A
0.013 %
56 mA + 7 mA/A
0.19 A + 4.3 mA/A
0.93 A + 4.3 mA/A
Fluke 5700A
Fluke 5700A w/ 5725A
Fluke 5522A
Agilent 3458A w/
Guildline 9211A
Fluke 5522A w/
5500A/coil
DC Current – Measure3
Up to 2 nA
(2 to 20) nA
(20 to 200) nA
(0.2 to 2) µA
(2 to 20) µA
(20 to 200) µA
(0.2 to 2) mA
(0 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
0.51 pA + 3 mA/A
7.1 pA + 2.1 mA/A
51 pA + 1.6 mA/A
0.51 nA + 1.6 mA/A
4.1 nA + 1.1 mA/A
41 nA + 1 mA/A
0.41 µA + 0.99 mA/A
41 pA + 89 µA/A
41 pA + 28 µA/A
0.4 nA + 24 µA/A
0.82 nA + 22 µA/A
5.8 nA + 24 µA/A
53 nA + 21 µA/A
0.53 µA + 37 µA/A
10 µA + 0.11 mA/A
Keithley 486
Agilent 3458A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 4 of 28
Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments
DC Current – Measure3
(cont)
(1 to 10) A
(10 to 100) A
(100 to 300) A
(300 to 1500) A
0.0025 %
0.0052 %
0.0054 %
0.2 %
Agilent 3458A w/:
Guildline 9211A
Empro shunt
DC Resistance – Generate,
Fixed Points
3
333 µΩ
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
1 Ω
10 kΩ
0.0046 %
0.0045 %
0.0018 %
0.0018 %
0.0014 %
0.0014 %
0.0014 %
0.0014 %
0.0014 %
8.9 µΩ
46 mΩ
Guildline 9211A
Fluke 742A-1
Fluke 742A-10K
DC Resistance – Generate,
Fixed Points
3
Up to 1000 V
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 TΩ
39 µΩ
86 µΩ
0.16 mΩ
0.26 mΩ
0.46 mΩ
1.6 mΩ
3 mΩ
12 mΩ
22 mΩ
0.11 Ω
0.21 Ω
1.2 Ω
2.4 Ω
18 Ω
35 Ω
0.36 kΩ
0.81 kΩ
39 kΩ
21 Ω
0.38 kΩ
12 kΩ
0.61 MΩ
2.4 MΩ
0.36 GΩ
5 GΩ
0.15 TΩ
Fluke 5700A
IET VRS-100-8-1M-
BP | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 5 of 28
Parameter/Equipment
Range
CMC2, 4, 6, 7 (±)
Comments
DC Resistance – Generate,
Fixed Points3 (cont)
Up to 5000 V
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 TΩ
5.4 kΩ
50 kΩ
0.5 MΩ
5 MΩ
50 MΩ
0.5 GΩ
5 GΩ
0.27 TΩ
IET VRS-100-8-1M-
BP
DC Resistance – Measure3
(0 to 1) Ω
(1 to 10) Ω
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
3.2 µΩ + 71 µΩ/Ω
86 µΩ + 60 µΩ/Ω
55 µΩ + 15 µΩ/Ω
0.52 mΩ + 13 µΩ/Ω
0.53 mΩ + 10 µΩ/Ω
5.3 mΩ + 10 µΩ/Ω
53 mΩ + 11 µΩ/Ω
2.3 Ω + 17 µΩ/Ω
0.1 kΩ + 55 µΩ/Ω
1 kΩ + 0.52 mΩ/Ω
10 kΩ + 5.1 mΩ/Ω
Agilent 34420A
Agilent 3458A
DC Resistance – Measure3
333 µΩ
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
0.0051 %
0.005 %
0.0028 %
0.0028 %
0.0025 %
0.0025 %
0.0025 %
0.0025 %
0.0025 %
Current transfer
method using
Guildline 9211A,
Agilent 3458A | 0 to 10 TΩ |
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 6 of 28
Parameter/Equipment
Range
CMC2, 6, 7 (±)
Comments
Resistance – Generate3
Up to 10.9999 Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 1.099 999) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.999) kΩ
(110 to 329.999) kΩ
(0.33 to 1.099 99) MΩ
(1.1 to 3.299 99) MΩ
(3.3 to 10.9999) MΩ
(11 to 32.9999) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
1.1 mΩ + 23 µΩ/Ω
1.4 mΩ + 23 µΩ/Ω
2 mΩ + 22 µΩ/Ω
4.4 mΩ + 22 µΩ/Ω
9.8 mΩ + 22 µΩ/Ω
42 mΩ + 22 µΩ/Ω
98 mΩ + 22 µΩ/Ω
0.42 Ω + 22 µΩ/Ω
0.97 Ω + 22 µΩ/Ω
8.2 Ω + 25 µΩ/Ω
14 Ω + 25 µΩ/Ω
90 Ω + 47 µΩ/Ω
0.39 kΩ + 0.1 mΩ/Ω
4.2 kΩ + 0.19 mΩ/Ω
15 kΩ + 0.39 mΩ/Ω
0.34 MΩ + 2.3 mΩ/Ω
4.2 MΩ + 12 mΩ/Ω
Fluke 5522A
Parameter/Range Frequency CMC2, 7 (±) Comments
AC Voltage – Generate3
Up to 2.2 mV
(2.2 to 22) mV
(22 to 220) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
3.9 µV + 0.47 mV/V
3.9 µV + 0.19 mV/V
3.9 µV + 93 µV/V
3.9 µV + 0.32 mV/V
6.2 µV + 0.74 mV/V
12 µV + 1 mV/V
23 µV + 1.4 mV/V
31 µV + 3.7 mV/V
5.7 µV + 0.47 mV/V
5.1 µV + 0.19 mV/V
4.9 µV + 93 µV/V
5.4 µV + 0.32 mV/V
7.9 µV + 0.74 mV/V
14 µV + 1 mV/V
27 µV + 1.4 mV/V
40 µV + 3.7 mV/V
23 µV + 0.47 mV/V
12 µV + 0.19 mV/V
9.7 µV + 85 µV/V
14 µV + 0.28 mV/V
39 µV + 0.7 mV/V
43 µV + 0.85 mV/V
63 µV + 1.4 mV/V
0.14 mV + 2.8 mV/V
Fluke 5700A/5725A
w/wideband option | to 1100 MΩ |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 7 of 28
Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments
AC Voltage – Generate3
(cont)
(0.22 to 2.2) V
(2.2 to 22) V
Amplitude Flatness
Up to 1.1 mV
(1.1 to 3) mV
(3 to 11) mV
(11 to 33) mV
(33 to 110) mV
(110 to 330) mV
(0.33 to 1.1) V
(1.1 to 3.5) V
Referenced to 1 kHz
Up to 1.1 mV
(1.1 to 3) mV
≥ 3 mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
30 Hz to 500 kHz
(10 to 30) Hz
30 Hz to 120 kHz
120 kHz to 2 MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
30 Hz to 120 kHz
120 kHz to 2 MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
30 Hz to 120 kHz
120 kHz to 2 MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
0.18 mV + 0.47 mV/V
55 µV + 0.14 mV/V
38 µV + 66 µV/V
40 µV + 0.11 mV/V
0.11 mV + 0.22 mV/V
0.2 mV + 0.37 mV/V
0.65 mV + 0.88 mV/V
1.2 mV + 1.9 mV/V
1.8 mV + 0.47 mV/V
0.55 mV + 0.14 mV/V
0.21 mV + 66 µV/V
0.4 mV + 0.11 mV/V
0.79 mV + 0.22 mV/V
2.4 mV + 0.47 mV/V
6.3 mV + 1.1 mV/V
12 mV + 2.3 mV/V
2.2 µV + 6.2 mV/V
8.4 µV + 5.4 mV/V
23 µV + 5.4 mV/V
68 µV + 4.7 mV/V
0.19 mV + 4.7 mV/V
0.51 mV + 3.9 mV/V
1.6 mV + 3.9 mV/V
3.8 mV + 3.1 mV/V
1.3 µV + 2.3 mV/V
0.44 µV + 0.76 mV/V
3.2 µV + 1.6 mV/V
4 µV + 3.1 mV/V
4.9 µV + 4.7 mV/V
18 µV + 12 mV/V
2.6 µV + 2.3 mV/V
0.86 µV + 0.77 mV/V
3.2 µV + 0.77 mV/V
4.9 µV + 2.3 mV/V
6.6 µV + 3.9 mV/V
15 µV + 12 mV/V
0.23 %
0.078 %
3 µV + 0.078 %
3 µV + 0.16 %
3 µV + 0.31 %
3 µV + 0.78 %
Fluke 5700A/5725A
w/wideband option | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 8 of 28
Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments
AC Voltage – Generate3
(cont)
Referenced to 1 kHz
(22 to 220) V*
(220 to 1100) V
(220 to 750) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(15 to 50) Hz**
50 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
18 mV + 0.47 mV/V
5.5 mV + 0.14 mV/V
2.4 mV + 70 µV/V
7.7 mV + 0.19 mV/V
18 mV + 0.47 mV/V
0.11 V + 1.2 mV/V
0.18 V + 4.2 mV/V
0.39 V + 10 mV/V
95 mV + 0.36 mV/V
19 mV + 70 µV/V
36 mV + 0.13 mV/V
0.11 V + 0.46 mV/V
0.11 V + 0.46 mV/V
0.43 V + 1.8 mV/V
Fluke 5700A/5725A
w/wideband option
*220 V range subject
to 2.2E7 V-Hz
limitation
** Maximum 250 V
AC Voltage – Measure3
(0.1 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
3.3 µV + 0.3 mV/V
1.3 µV + 0.2 mV/V
1.4 µV + 0.3 mV/V
2.1 µV + 1 mV/V
6.1 µV + 5 mV/V
42 µV + 40 mV/V
4.7 µV + 7 µV/V
2.7 µV + 7 µV/V
3.4 µV + 14 µV/V
5 µV + 0.3 mV/V
10 µV + 0.8 mV/V
40 µV + 3 mV/V
0.11 mV + 10 mV/V
0.16 V + 15 mV/V
47 µV + 7 µV/V
27 µV + 7 µV/V
35 µV + 14 µV/V
50 µV + 0.3 mV/V
0.1 mV + 0.8 mV/V
0.4 mV + 3 mV/V
1.1 mV + 10 mV/V
1.6 mV + 15 mV/V
Agilent 3458A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 9 of 28
Parameter/Range Frequency CMC2, 6, 7 (±) Comments
AC Voltage – Measure3
(cont)
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.47 mV + 7 µV/V
0.27 mV + 7 µV/V
0.34 mV + 14 µV/V
0.5 mV + 0.3 mV/V
1 mV + 0.8 mV/V
4 mV + 3 mV/V
11 mV + 10 mV/V
16 mV + 15 mV/V
6 mV + 0.2 mV/V
4 mV + 0.2 mV/V
4 mV + 0.2 mV/V
5.5 mV + 0.35 mV/V
14 mV + 1.2 mV/V
50 mV + 4 mV/V
0.16 V + 15 mV/V
56 mV + 0.4 mV/V
42 mV + 0.4 mV/V
56 mV + 0.6 mV/V
98 mV + 1.2 mV/V
0.22 V + 3 mV/V
Agilent 3458A
AC High Voltage3 –
Measure
(1 to 10) kV
(10 to 50) kV
50/60/400 Hz
0.16 %
0.12 %
Vitrek 4700
w/HVL-70
AC Flatness – Measure3,9
Up to 3 V
10 Hz
100 Hz
10 kHz
30 kHz
100 kHz
300 kHz
1 MHz
2 MHz
10 MHz
20 MHz
30 MHz
50 MHz
100 MHz
0.096 %
0.096 %
0.096 %
0.096 %
0.096 %
0.096 %
0.096 %
0.098 %
0.13 %
0.19 %
0.24 %
0.53 %
1.4 %
Thermal voltage
converter | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 10 of 28
Parameter/Range
Frequency CMC2, 6, 7 (±) Comments
AC Current – Generate3
(0 to 220) µA
(29 to 329.99) µA
(0.22 to 2.2) mA
(0.33 to 3.2999) mA
(2.2 to 22) mA
(3.3 to 32.999) mA
(22 to 220) mA
(33 to 329.99) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
Non-Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
66 nA + 0.5 mA/A
23 nA + 0.33 mA/A
17 nA + 0.12 mA/A
45 nA + 0.54 mA/A
93 nA + 1.4 mA/A
0.67 µA + 12 mA/A
0.18 µA + 0.62 mA/A
0.1 µA + 0.33 mA/A
59 nA + 0.12 mA/A
0.51 µA + 0.54 mA/A
1.1 µA + 1.4 mA/A
3.2 µA + 7.7 mA/A
1.8 µA + 0.62 mA/A
1 µA + 0.33 mA/A
0.59 µA + 0.12 mA/A
5.1 µA + 0.54 mA/A
11 µA + 1.4 mA/A
13 µA + 3.1 mA/A
18 µA + 0.62 mA/A
10 µA + 0.33 mA/A
6.2 µA + 0.14 mA/A
51 µA + 0.54 mA/A
0.11 mA + 1.4 mA/A
0.26 mA + 3.1 mA/A
0.16 mA + 0.58 mA/A
0.22 mA + 0.66 mA/A
1.9 mA + 7.8 mA/A
0.92 mA + 0.36 mA/A
1.9 mA + 0.74 mA/A
6.7 mA + 2.8 mA/A
14 mA + 0.9 mA/A
17 mA + 1.2 mA/A
0.26 A + 23 mA/A
34 mA + 2.9 mA/A
61 mA + 2.8 mA/A
0.46 A + 2.8 mA/A
0.064 A + 0.0064 A/A
0.11 A + 0.0057 A/A
0.92 A + 0.0057A/A
63 mA + 4.4 mA/A
0.23 A + 4.2 mA/A
1.2 A + 4.3 mA/A
93 mA + 7.6 mA/A
0.28 A + 7 mA/A
1.6 A + 7 mA/A
Fluke 5700A
Fluke 5522A
Fluke 5700 w/ 5725A
Fluke 5522A
Fluke 5522A w/
5500 coil | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 11 of 28
Parameter/Range
Frequency CMC2, 4, 6, 7 (±) Comments
AC Current – Measure3
(5 to 100) µA
(8.0 to 1) mA
(1 to 10) mA
(10 to 100) mA
(8.0 to 1) A
(1 to 20) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(8.0 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(8.0 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(8.0 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(8.0 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
Up to 1 kHz
(1 to 5) kHz
55 nA + 4 mA/A
42 nA + 1.5 mA/A
38 nA + 0.64 mA/A
0.41 µA + 4.1 mA/A
0.28 µA + 1.6 mA/A
0.24 µA + 0.67 mA/A
0.22 µA + 0.37 mA/A
0.24 µA + 0.67 mA/A
0.61 µA + 4.1 mA/A
1.8 µA + 5.6 mA/A
2.2 µA + 4.1 mA/A
2.1 µA + 1.6 mA/A
2 µA + 0.67 mA/A
2 µA + 0.37 mA/A
2 µA + 0.67 mA/A
4.2 µA + 4.1 mA/A
15 µA + 5.6 mA/A
40 µA + 4 mA/A
28 µA + 1.5 mA/A
23 µA + 0.6 mA/A
22 µA + 0.3 mA/A
23 µA + 0.6 mA/A
60 µA + 4 mA/A
0.18 mA + 5.5 mA/A
0.4 mA + 4.1 mA/A
0.28 mA + 1.7 mA/A
0.24 mA + 0.9 mA/A
0.25 mA + 1.1 mA/A
0.35 mA + 3.1 mA/A
0.9 mA + 10 mA/A
0.026 %
0.039 %
Agilent 3458A
Agilent 3458A, Fluke
Y5020 | 5 to 100 µA |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 12 of 28
Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments
Capacitance – Generate3
(0.19 to 0.3999) nF
0.4 to 1.0999) nF
(1.1 to 3.299) nF
(3.3 to 10.999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.99) nF
(0.33 to 1.0999) µF
(1.1 to 3.2999) µF
(3.3 to 10.999) µF
(11 to 32.999) µF
(33 to 109.99) µF
(110 to 329.99) µF
(0.33 to 1.0999) mF
(1.1 to 3.2999) mF
(3.3 to 10.999) mF
(11 to 32.999) mF
(33 to 110) mF
(1 to 10) pF
(10 to 100) pF
(100 to 1000) pF
(1 to 10) nF
(10 to 100) nF
100 nF to 1.1 µF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
Up to 50 Hz
Up to 20 Hz
Up to 6 Hz
Up to 2 Hz
Up to 0.6 Hz
Up to 0.2 Hz
1 kHz
8.5 pF + 3.8 pF/nF
9.4 pF + 3.9 pF/nF
12 pF + 3.9 pF/nF
15 pF + 2 pF/nF
0.1 nF + 1.9 pF/nF
0.14 nF + 1.9 pF/nF
0.45 nF + 1.9 pF/nF
1.4 nF + 1.9 nF/µF
4.4 nF + 1.9 nF/µF
14 nF + 1.9 nF/µF
58 nF + 3.1 nF/µF
0.19 µF + 3.5 nF/µF
0.62 µF + 3.5 nF/µF
1.9 µF + 3.5 µF/mF
6.8 µF + 3.4 µF/mF
38 µF + 2.4 µF/mF
87 µF + 5.8 µF/mF
0.36 mF + 8.5 µF/mF
0.12 pF
0.12 pF
0.13 pF + 0.015 %
0.31 pF + 0.016 %
1.8 pF + 0.027 %
26 pF + 0.045 %
Fluke 5522A
GenRad 1413
Capacitance – Measure3
(8.0 to 10) nF
10 nF to 10 µF
(10 to 100) µF
(100 to 1000) µF
(1 to 10) mF
(10 to 100) mF
100 Hz to 1 kHz
0.91 %
0.88 %
0.99 %
0.98 %
1.0 %
2.7 %
Agilent U1252A
Distortion3
(-101 to 0) dB
(-70 to +10) dB
20 Hz to 20 kHz
(20 to 100) kHz
100 kHz to 3 GHz
(3 to 6.5) GHz
(6.5 to 22) GHz
(22 to 26.5) GHz
1.2 dB
2.3 dB
0.85 dB
1.9 dB
2.4 dB
3 dB
Agilent U8903A
Agilent E4440A | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 13 of 28
Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments
Pulse Characterization3 –
Rise & Fall Time Measure
350 ps to 1 ns
33 ps
Agilent
DSO8104A
Oscilloscopes3 –
Voltage
DC into 50 Ω
DC into 1 MΩ
Squarewave into 50 Ω
Squarewave into 1 MΩ
Fast Edge into 50 Ω
Leveled Sine Wave
(Relative to 50 kHz)
Leveled Sine Wave
(Relative to 10 MHz)
Time Marker
± (0 to 6.6) V
± (0 to 130) V
1 mV to 6.6 V
p-p
1 mV to 130 Vp-p
Nominal 150 ps
50 kHz Reference
50 kH to 100 MHz
(100 to 300) MHz
(300 to 500) MHz
(500 to 600) MHz
10 MHz Reference
600 MHz to 1.6 GHz
(1.6 to 2.1) GHz
5 s to 50 ms
20 ms to 200 ps
44 µV + 2.5 mV/V
31 µV + 0.25 mV/V
44 µV + 2.5 mV/V
17 µV + 0.5 mV/V
25 ps
0.41 mV + 20 mV/V
0.51 mV + 38 mV/V
0.54 mV + 45 mV/V
0.64 mV + 65 mV/V
0.67 mV + 72 mV/V
0.41 mV + 20 mV/V
0.74 mV + 86 mV/V
0.81 mV + 0.1 V/V
0.0003 % + 5 ns
0.000 033 %
Fluke 5820A | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 14 of 28
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power3 –
Generate
See Table below See Table below Fluke 5522A
(45 to 65) Hz (3.366 to
33.66) W
(33.66 to
336.6) W
(0.3366 to
1.122) kW
(1.122 to
3.06) kW
(3.06 to
11.22) kW
(11.22 to 20.9)
kW
Ø 0 °
PF=1.000 0.052 % 0.068 % 0.076 % 0.083 % 0.17 %
Ø 10 °
PF=0.985 0.06 % 0.075 % 0.082 % 0.088 % 0.18 %
Ø 20 °
PF=0.940 0.082 % 0.093 % 0.099 % 0.1 % 0.18 %
Ø 30 °
PF=0.866 0.11 % 0.12 % 0.13 % 0.2 %
Ø 40 °
PF=0.766 0.16 % 0.17 % 0.23 %
Ø 50 °
PF=0.643 0.21 % 0.22 % 0.27 %
Ø 60 °
PF=0.500 0.31 % 0.35 %
Ø 70 °
PF=0.342 0.48 % 0.49 % 0.51 %
Ø 80 °
PF=0.174 0.99 % 1 %
(65 to 500) Hz (33.66 to
336.6) W
(0.3366 to
1.122) kW
(1.122 to 3.06)
kW
(3.06 to 11.22)
kW
(11.22 to 20.9)
kW
Ø 0 °
PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 %
Ø 10 °
PF=0.985 0.094 % 0.1 % 0.11 % 0.14 % 0.22 %
Ø 20 °
PF=0.940 0.17 % 0.18 % 0.2 % 0.26 %
Ø 30 °
PF=0.866 0.26 % 0.28 % 0.33 %
Ø 40 °
PF=0.766 0.37 % 0.39 % 0.42 %
Ø 50 °
PF=0.643 0.53 % 0.56 %
Ø 60 °
PF=0.500 0.76 % 0.77 % 0.78 %
Ø 70 °
PF=0.342 1.2 %
Ø 80 °
PF=0.174 2.5 % | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 15 of 28
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power3 –
Generate
See Table below See Table below Fluke 5522A
500 Hz to 1 kHz (33.66 to
336.6) W
(0.3366 to
1.122) kW
(1.122 to 3.06)
kW
(3.06 to 11.22)
kW
(11.22 to 20.9)
kW
Ø 0 °
PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 %
Parameter/Range
Frequency CMC2, 4, 6, 7 (±) Comments
Inductance – Generate3,
Fixed Point
1 mH
10 mH
100 mH
1 H
10 H
100 µH to 1 mH
(1 to 10) mH
(10 to 100) mH
100 mH to 1 H
(1 to 10) H
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
400 Hz
1 kHz
100 Hz
200 Hz
400 Hz
1 kHz
400 Hz & 1 kHz
0.65 µH
0.71 µH
0.49 µH
0.6 µH
0.47 µH
0.82 µH
0.87 µH
0.56 µH
0.54 µH
0.63 µH
4.5 µH
4.5 µH
4.4 µH
4.4 µH
4.4 µH
0.31 mH
0.27 mH
0.3 mH
0.6 mH
0.56 mH
0.61 mH
5.9 mH
0.015 µH + 0.0023 %
1 µH + 0.1 %
5.2 µH + 0.5 %
53 µH + 0.049 %
1.9 µH + 0.09 %
GenRad 1482-E
GenRad 1482-H
GenRad 1482-L
GenRad 106-M
GenRad 1482-T
GenRad 1491-G | ||
| 16 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 16 of 28
Parameter/Equipment Range CMC2, 4 (±) Comments
DC Power – Generate3
Up to 330 µA
Up to 3.3 mA
Up to 33 mA
Up to 330 mA
Up to 1.1 A
Up to 3 A
Up to 11 A
Up to 20.5 A
Up to 1020 V
Up to 337 mW
(0.337 to 3.366) W
(3.366 to 33.66) W
(33.66 to 336.6) W
(0.3366 to 1.122) kW
(1.122 to 3.06) kW
(3.06 to 11.22) kW
(11.22 to 20.91) kW
0.017 %
0.021 %
0.0093 %
0.0093 %
0.019 %
0.043 %
0.044 %
0.13 %
Fluke 5520A
Duty Cycle3
(1 to 9.99) %
(10 to 49.99) %
At 50 %
(50.01 to 90) %
(90.01 to 99) %
0.32 %
0.02 %
0.013 %
0.02 %
0.032 %
Fluke 5522A
Electrical Calibration of
RTDs – Measure3
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
(-200 to 80) °C
(-80 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 630) °C
0.019 °C
0.023 °C
0.027 °C
0.031 °C
0.038 °C
0.048 °C
0.018 °C
0.018 °C
0.02 °C
0.024 °C
0.029 °C
0.038 °C
0.017 °C
0.018 °C
0.019 °C
0.019 °C
0.025 °C
0.03 °C
0.036 °C
0.043 °C
0.054 °C
0.057 °C
0.061 °C
0.061 °C
0.071 °C
0.073 °C
0.09 °C
Fluke 7526A | to 1020 |
| 17 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 17 of 28
Parameter/Equipment Range CMC2 (±) Comments
Electrical Calibration of
RTDs – Measure3 (cont)
Pt 385, 500 Ω
Pt 385, 1000 Ω
Ni 120, 120 Ω
Cu 427, 10 Ω
YSI 400
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-80 to 260) °C
(-100 to 260) °C
(15 to 50) °C
0.029 °C
0.029 °C
0.036 °C
0.041 °C
0.049 °C
0.02 °C
0.02 °C
0.027 °C
0.03 °C
0.038 °C
0.0097 °C
0.11 °C
0.0071 °C
Fluke 7526A
Electrical Calibration of
RTDs – Generate3
PT 385, 100 Ω
PT 3926, 100 Ω
PT 3916, 100 Ω
PT 385, 200 Ω
PT 385, 500 Ω
PT 385, 1000 Ω
Ni 120, 120 Ω
Cu 427, 10 Ω
YSI 400
(-200 to 800) °C
(-200 to 630) °C
(-200 to 630) °C
(-200 to 400) °C
(400 to 630) °C
(-200 to 630) °C
(-200 to 630) °C
(-80 to 260) °C
(-100 to 260) °C
(15 to 50) °C
0.052 °C
0.052 °C
0.052 °C
0.4 °C
0.5 °C
0.17 °C
0.091 °C
0.021 °C
0.38 °C
0.009 °C
Fluke 7526A | -200 to 800 °C |
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 18 of 28
Parameter/Equipment Range CMC2 (±) Comments
Thermal Reference Probes
(Half Junctions)
Type E
Type J
Type K
Type T
0 °C
0 °C
0 °C
0 °C
0.12 °C
0.12 °C
0.13 °C
0.13 °C
Omega ice point,
Fluke 5700A,
Agilent 3458A
Thermocouple – Indicating
Systems & Measure3
Type B
Type C
Type E
Type J
Type K
Type L
(600 to 800) °C
(800 to 1550) °C
(1550 to 1820) °C
(0 to 1000) °C
(1000 to 1800) °C
(1800 to 2000) °C
(2000 to 2316) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 600) °C
(600 to 1000) °C
(-210 to -100) °C
(-100 to 800) °C
(800 to 1200) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 500) °C
(500 to 800) °C
(800 to 1372) °C
(-200 to -100) °C
(-100 to 900) °C
0.35 °C
0.28 °C
0.23 °C
0.16 °C
0.23 °C
0.27 °C
0.36 °C
0.25 °C
0.12 °C
0.091 °C
0.082 °C
0.1 °C
0.14 °C
0.091 °C
0.11 °C
0.46 °C
0.16 °C
0.1 °C
0.1 °C
0.14 °C
0.1 °C
0.092 °C
Fluke 7526A | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 19 of 28
Parameter/Equipment Range CMC2 (±) Comments
Thermocouple – Indicating
Systems & Measure3 (cont)
Type N
Type R
Type S
Type T
Type U
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 100) °C
(100 to 800) °C
(800 to 1300) °C
(-50 to -25) °C
(-25 to 0) °C
(0 to 100) °C
(100 to 400) °C
(400 to 600) °C
(600 to 1000) °C
(1000 to 1600) °C
(1600 to 1767) °C
(-50 to -25) °C
(-25 to 0) °C
(0 to 100) °C
(100 to 400) °C
(400 to 600) °C
(600 to 1000) °C
(1000 to 1600) °C
(1600 to 1767) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 200) °C
(200 to 400) °C
(-200 to 0) °C
(0 to 200) °C
(200 to 600) °C
0.73 °C
0.23 °C
0.12 °C
0.11 °C
0.1 °C
0.13 °C
0.55 °C
0.45 °C
0.39 °C
0.28 °C
0.22 °C
0.21 °C
0.2 °C
0.24 °C
0.51 °C
0.43 °C
0.38 °C
0.29 °C
0.23 °C
0.22 °C
0.22 °C
0.27 °C
0.35 °C
0.16 °C
0.14 °C
0.12 °C
0.12 °C
0.23 °C
0.1 °C
0.1 °C
Fluke 7526A | ||
| 20 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 20 of 28
III. Electrical – RF/Microwave
Parameter/Range Frequency CMC2, 4, 5, 6 (±) Comments
Amplitude Modulation3 –
Measure
(5 to 99) % depth
(5 to 20) % depth
(20 to 99) % depth
(5 to 20) % depth
(20 top 99) % depth
100 kHz to 10 MHz
10 MHz to 3 GHz
(3 to 26.5) GHz
0.86 % of depth
2.6 % of depth
0.78 % of depth
4.6 % of depth
1.7 % of depth
Agilent E4440A
Frequency Modulation3 –
Measure
Modulation rate:
20 Hz to 10 kHz
Deviation:
200 Hz to 40 kHz
Modulation rate:
50 Hz to 200 kHz
Deviation:
250 Hz to 400 kHz
250 kHz to 10 MHz
10 MHz to 6.6 GHz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
1.5 %
1.5 %
2.5 %
3.8 %
Agilent E4440A
Phase Modulation3 –
Measure
(0.3 to ≤ 0.7) rad
> 0.7 rad
(0.6 to ≤ 2.0) rad
2.0 rad
(1.2 to ≤ 4.0) rad
> 4.0 rad
100 kHz to 6.6 GHz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
3 %
8.0 %
3 %
1.1 %
3 %
1.1 %
Agilent E4440A | 5 to 99 % |
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 21 of 28
Parameter/Range Frequency CMC2, 4, 5, 6 (±) Comments
Relative Power3 – Measure
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
(-120 to -130) dB
100 kHz to 26.5 GHz
0.031 dB
0.035 dB
0.039 dB
0.058 dB
0.06 dB
0.064 dB
0.077 dB
0.082 dB
0.086 dB
0.096 dB
0.1 dB
0.11 dB
0.12 dB
Agilent E4440A
Absolute Power – Measure3
(-20 to +30) dBm
(-60 to +20) dBm
(-70 to +20) dBm
(-20 to +30) dBm
100 kHz to 4.2 GHz
9 kHz to 6 GHz
50 MHz to 3 GHz
(3 to 9.2) GHz
(9.2 to 13.5) GHz
(13.5 to 22) GHz
(22 to 26.5) GHz
50 MHz to 3 GHz
(3 to 9.2) GHz
(9.2 to 13.5) GHz
(13.5 to 22) GHz
(22 to 26.5) GHz
3.7 %
3.7 %
3.8 %
3.9 %
4.1 %
4.4 %
4.7 %
3.8 %
3.9 %
4.1 %
4.4 %
4.7 %
Agilent N1914A
w/:
Agilent N5532B
Agilent E9304A
Agilent E4413A
Agilent N5532A | ||
| 22 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 22 of 28
Parameter/Range Frequency CMC2, 5, 6 (±) Comments
Attenuation – Measure3
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
(-120 to -127) dB
10 MHz to 26.5 GHz
0.039 dB
0.042 dB
0.045 dB
0.062 dB
0.064 dB
0.068 dB
0.081 dB
0.085 dB
0.089 dB
0.099 dB
0.11 dB
0.11 dB
0.13 dB
Agilent E4440A
Attenuation – Generate3
(1 to 11) dB
(10 to 60) dB
(70 to 110) dB
(110 to 121) dB
DC to 4 GHz
0.21 dB
0.3 dB
0.31 dB
0.32 dB
HP 8494G &
HP 8496G step
attenuators
Displayed Average Noise
Level3
(-160 to -50) dBm
45 MHz to ≤ 2 GHz
(2 to ≤ 3) GHz
(3 to ≤ 6) GHz
(6 to ≤ 9) GHz
0.73 dB
0.85 dB
0.92 dB
1.1 dB
Agilent 85032F 50
Ω termination
Return Loss (VSWR)3
Up to 60 dB
(Up to 1:1 VSWR)
(100 to 300) kHz
300 kHz to 1 GHz
(1 to 3) GHz
(2 to 12.4) GHz
(12.4 to 18) GHz
(18 to 26.5) GHz
1.1 dB
1.0 dB
1.1 dB
1.4 dB
1.8 dB
2.8 dB
Agilent E4440A
w/: directional
coupler & SWR
bridge | to 60 dB |
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 23 of 28
Parameter/Range
Frequency CMC2, 4, 5, 6 (±) Comments
Single Side-Band Phase
Noise3 – Measure
Carrier: 1 MHz to 26.5 GHz
At offsets:
10 Hz
100 Hz
1 kHz
10 kHz
20 kHz
100 kHz
1 MHz
10 MHz
2.7 dB
2.7 dB
2.5 dB
2.4 dB
2.4 dB
2.4 dB
2.4 dB
2.4 dB
Agilent E4440A
(see below)
E4440A system noise floor limits
SSB measurements at the
following offsets as indicated
Up to 600 MHz
601 MHz to 10.1 GHz
(10.3 to 26.5) GHz
10 Hz offset -102 dBc/Hz -84 dBc/Hz -76 dBc/Hz
100 Hz offset -102 dBc/Hz -84 dBc/Hz -76 dBc/Hz
1 kHz offset -114 dBc/Hz -104 dBc/Hz -95 dBc/Hz
10 kHz offset -120 dBc/Hz -114 dBc/Hz -105 dBc/Hz
100 kHz offset -125 dBc/Hz -120 dBc/Hz -120 dBc/Hz
1 MHz offset -150 dBc/Hz -145 dBc/Hz -158 dBc/Hz
10 MHz offset -158 dBc/Hz -150 dBc/Hz -140 dBc/Hz | ||
| 24 | EURAMET CG-18 | - | to 7.4 kg |
| 25 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 25 of 28
Parameter/Equipment Range CMC2, 4, 5 (±) Comments
Torque – Measure
Tools3
(4 to 8) ozf·in
(8 to 40) ozf·in
(5 to 50) lbf·in
(20 to 200) lbf·in
(50 to 100) lbf·in
(100 to 500) lbf·in
(25 to 50) lbf·ft
(50 to 250) lbf·ft
(30 to 300) lbf·ft
(5 to 50) lbf·in
(40 to 400) lbf·in
(100 to 1000) lbf·in
(25 to 250) lbf·ft
(60 to 600) lbf·ft
1.2 %
0.58 %
0.59 %
0.33 %
1.2 %
0.6 %
1.2 %
0.59 %
0.13 %
0.3 %
0.3 %
0.31 %
0.3 %
0.31 %
Mountz BMX40Z
TL-50i
AKO TSD011/020
BMX500I
BMX250F
AKO TSD321BT
CDI 2000-400-02
CDI 2000-12-02
Pressure – Measure &
Measuring Equipment3
Hydraulic
Pneumatic
(10 to 10 000) psig
(0 to 5) inH2O
(0 to 25) inH2O
(8 to 17) psia
(-15 to 83) psig
(83 to 150) psig
(-15 to 758) psig
(758 to 1500) psig
0.018 %
0.096 %
0.082 %
0.023 %
0.019 psi
0.023 %
0.18 psi
0.023 %
Ametek DM-T-150
DWT
Ashcroft AQS-1
Ashcroft AM2-1
Mensor CPC4000 | ||
| 26 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 26 of 28
VI. Thermodynamics
Parameter/Equipment Range CMC2, 4, 5, 6 (±) Comments
Temperature – Measure3
(-197 to 0) °C
(0 to 420) °C
(420 to 600) °C
0.028 °C + ΔTChange from -197 °C x
0.000 058 °C
0.017 °C + 0.000 054 °C/°C
0.042 °C + ΔTChange from 420 °C x
0.000 23 °C
Fluke 1502A w/
5614 PRT
5614 PRT
5609 PRT
Temperature –
Measuring Equipment3
-78 °C
(-45 to 140) °C
(-30 to 125) °C
(35 to 200) °C
(35 to 420) °C
(420 to 600) °C
0.074 °C
0.065 °C
0.046 °C + ΔTChange from -30 °C x
0.000 18 °C
0.038 °C + ΔTChange from 35 °C x
0.000 088 °C
0.065 °C + ΔTChange from 35 °C x
0.000 067 °C
0.092 °C + ΔTChange from 420 °C x
0.000 14 °C
Fluke 1502A w/
5614 PRT, 5609
PRT, dry wells, dry
ice bath
Infrared Temperature –
Measuring Equipment
Emissivity = 0.95
Wavelength (8 to 14)
µm
(-15 to -12) °C
(-12 to -8) °C
(-8 to -4) °C
(-4 to 0) °C
(0 to 120) °C
(35 to 500) °C
0.51 °C
0.5 °C
0.49 °C
0.48 °C
0.6 °C + 0.0017 °C/°C
0.54 °C + ΔTChange from 35 °C x
0.0042 °C
Hart 4180
Hart 4181
Relative Humidity –
Measuring Equipment3
(15 to 80) % RH
(> 80 to 95) % RH
1.4 % RH
2.1 % RH
Kaymont 2000
Relative Humidity –
Measure3
(20 to 90) % RH
(90 to 95) % RH
1.4 % RH
2.1 % RH
Vaisala MI70 &
HMP77 | ||
| 27 | NIST 960-12 | - | See scope document |
| 28 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1022.03) 07/16/2024 Page 28 of 28
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, R is the numerical value of the resolution of the device in its respective units
and percentages are percentage of reading unless otherwise indicated.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 CMC components that can be reasonably attributed to the Unit Under Test have not been utilized in the
calculation of the CMC value for this measurement parameter.
7 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as eit her a specific value that covers the full range or as a
percentage or fraction of the reading plus a fixed floor specification.
8 This scope meets A2LA’s P112 Flexible Scope Policy
9 For frequencies that fall in between the stated cardinal points, the CMC can be calculated by interpolating
the uncertainty from the frequency above and below the frequency of interest. | ||
| 29 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
718 West Algonquin Road, PO Box 559, Arlington Heights, IL, 60005, US
42.08116, -87.98022
Open in MapsLabs with overlapping accredited scope in United States
- J. H. MetrologyRolling Meadows, IL · ~3 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- GraftelRoselle, IL · ~13 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- DicksonAddison, IL · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- INNOCAL (Cole Palmer Instrument Co, LLC)Vernon Hills, IL · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- NovamedSkokie, IL · ~20 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.