Honeywell Process Solutions - Field Service Operations

512 Virginia Drive, 19034, Fort Washington, PA, United States

Visit website
A2LA 4885.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 4885.01 · 6 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4885.01) 06/24/2024 Page 1 of 5 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 HONEYWELL PROCESS SOLUTIONS – FIELD SERVICE OPERATIONS 512 Virginia Avenue Fort Washington, PA 19034 Phil Bors Phone: 860 218 5400 CALIBRATION Valid To: July 31, 2026 Certificate Number: 4885.01 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 7: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Voltage3 – Generate Measure Up to 100 mV (0.10 to 1.0) V (1.0 to 10) V Up to 110 mV (0.11 to 1.1) V (1.1 to 11) V 0.0067 mV 0.072 mV 0.8 mV 0.019 mV 0.097 mV 0.96 mV Fluke 754 Honeywell 2020/Fluke 744 DC Current3 – Generate (2 to 22) mA 0.0042 mA Honeywell 2020/Fluke 744 DC Current3 – Measure Up to 30 mA 0.0065 mA Honeywell 2020/Fluke 744
to 11 V
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4885.01) 06/24/2024 Page 2 of 5 Parameter/Equipment Range CMC2, 4 (±) Comments Electrical Calibration of Thermocouple Indicating Systems3 – Generate Type B Type J Type K Type N Type R Type S Type T (600 to 800) °C (800 to 1000) °C (1000 to 1820) °C (-210 to -100) °C (-100 to 800) °C (800 to 1200) °C (-200 to -100) °C (-100 to 400) °C (400 to 1200) °C (1200 to 1372) °C (-200 to -100) °C (-100 to 900) °C (900 to 1300) °C (-20 to 0) °C (0 to 100) °C (100 to 1767) °C (-20 to 0) °C (0 to 200) °C (200 to 1400) °C (1400 to 1767) °C (-250 to -200) °C (-200 to 0) °C (0 to 400) °C 1.4 °C 1.2 °C 1.2 °C 0.60 °C 0.50 °C 0.60 °C 0.71 °C 0.60 °C 0.60 °C 0.60 °C 0.94 °C 0.82 °C 0.60 °C 1.6 °C 1.5 °C 1.3 °C 1.6 °C 1.5 °C 1.3 °C 1.4 °C 1.3 °C 0.72 °C 0.61 °C Honeywell 2020/Fluke 744/754
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4885.01) 06/24/2024 Page 3 of 5 Parameter/Equipment Range CMC2, 4 (±) Comments Electrical Calibration of Thermocouple Systems3 – Measure Type B Type J Type K Type N Type R Type S Type T (600 to 800) °C (800 to 1000) °C (1000 to 1820) °C (-210 to -100) °C (-100 to 800) °C (800 to 1200) °C (-200 to -100) °C (-100 to 400) °C (400 to 1200) °C (1200 to 1372) °C (-200 to -100) °C (-100 to 900) °C (900 to 1300) °C (-20 to 0) °C (0 to 100) °C (100 to 1767) °C (-20 to 0) °C (0 to 200) °C (200 to 1400) °C (1400 to 1767) °C (-250 to -200) °C (-200 to 0) °C (0 to 400) °C 1.7 °C 1.4 °C 1.3 °C 0.94 °C 0.61 °C 0.82 °C 1.1 °C 0.60 °C 0.82 °C 1.1 °C 1.4 °C 0.83 °C 0.94 °C 2.9 °C 2.0 °C 1.4 °C 2.9 °C 2.0 °C 1.4 °C 1.5 °C 2.2 °C 0.94 °C 0.60 °C Honeywell 2020/Fluke 744/754
4AMS2750 SAT; AMS2750 TUS-See scope document
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4885.01) 06/24/2024 Page 5 of 5 Parameter/Equipment Range CMC2, 5 (±) Comments Relative Humidity3 – Measure (11.5 to 90) % RH 1.9 % RH Portable hygrometer IV. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Time Interval3 – Measure (5 to 3600) s 0.23 s Stopwatch 1 This laboratory offers commercial calibration and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards of nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the best uncertainty due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 Fluke/Honeywell 2020 CMCs based upon 1-year manufacturer’s floor specifications at 23 °C ± 5 °C. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eit her a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
11.5 to 90 % RH
6ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

512 Virginia Drive, Fort Washington, PA, 19034, US

40.14785, -75.18972

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.