Honeywell Process Solutions - Field Service Operations
512 Virginia Drive, 19034, Fort Washington, PA, United States
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 4885.01 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4885.01) 06/24/2024 Page 1 of 5
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
HONEYWELL PROCESS SOLUTIONS – FIELD SERVICE OPERATIONS
512 Virginia Avenue
Fort Washington, PA 19034
Phil Bors Phone: 860 218 5400
CALIBRATION
Valid To: July 31, 2026 Certificate Number: 4885.01
In recognition of the successful completion of the A2LA evaluation process, (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory to perform the following calibrations
1, 7:
I. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
DC Voltage3 –
Generate
Measure
Up to 100 mV
(0.10 to 1.0) V
(1.0 to 10) V
Up to 110 mV
(0.11 to 1.1) V
(1.1 to 11) V
0.0067 mV
0.072 mV
0.8 mV
0.019 mV
0.097 mV
0.96 mV
Fluke 754
Honeywell
2020/Fluke 744
DC Current3 – Generate
(2 to 22) mA
0.0042 mA
Honeywell
2020/Fluke 744
DC Current3 – Measure
Up to 30 mA
0.0065 mA
Honeywell
2020/Fluke 744 | to 11 V |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4885.01) 06/24/2024 Page 2 of 5
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Electrical Calibration of
Thermocouple Indicating
Systems3 – Generate
Type B
Type J
Type K
Type N
Type R
Type S
Type T
(600 to 800) °C
(800 to 1000) °C
(1000 to 1820) °C
(-210 to -100) °C
(-100 to 800) °C
(800 to 1200) °C
(-200 to -100) °C
(-100 to 400) °C
(400 to 1200) °C
(1200 to 1372) °C
(-200 to -100) °C
(-100 to 900) °C
(900 to 1300) °C
(-20 to 0) °C
(0 to 100) °C
(100 to 1767) °C
(-20 to 0) °C
(0 to 200) °C
(200 to 1400) °C
(1400 to 1767) °C
(-250 to -200) °C
(-200 to 0) °C
(0 to 400) °C
1.4 °C
1.2 °C
1.2 °C
0.60 °C
0.50 °C
0.60 °C
0.71 °C
0.60 °C
0.60 °C
0.60 °C
0.94 °C
0.82 °C
0.60 °C
1.6 °C
1.5 °C
1.3 °C
1.6 °C
1.5 °C
1.3 °C
1.4 °C
1.3 °C
0.72 °C
0.61 °C
Honeywell
2020/Fluke 744/754 | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4885.01) 06/24/2024 Page 3 of 5
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Electrical Calibration of
Thermocouple Systems3 –
Measure
Type B
Type J
Type K
Type N
Type R
Type S
Type T
(600 to 800) °C
(800 to 1000) °C
(1000 to 1820) °C
(-210 to -100) °C
(-100 to 800) °C
(800 to 1200) °C
(-200 to -100) °C
(-100 to 400) °C
(400 to 1200) °C
(1200 to 1372) °C
(-200 to -100) °C
(-100 to 900) °C
(900 to 1300) °C
(-20 to 0) °C
(0 to 100) °C
(100 to 1767) °C
(-20 to 0) °C
(0 to 200) °C
(200 to 1400) °C
(1400 to 1767) °C
(-250 to -200) °C
(-200 to 0) °C
(0 to 400) °C
1.7 °C
1.4 °C
1.3 °C
0.94 °C
0.61 °C
0.82 °C
1.1 °C
0.60 °C
0.82 °C
1.1 °C
1.4 °C
0.83 °C
0.94 °C
2.9 °C
2.0 °C
1.4 °C
2.9 °C
2.0 °C
1.4 °C
1.5 °C
2.2 °C
0.94 °C
0.60 °C
Honeywell
2020/Fluke 744/754 | ||
| 4 | AMS2750 SAT; AMS2750 TUS | - | See scope document |
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4885.01) 06/24/2024 Page 5 of 5
Parameter/Equipment
Range CMC2, 5 (±) Comments
Relative Humidity3 –
Measure
(11.5 to 90) % RH
1.9 % RH
Portable hygrometer
IV. Time & Frequency
Parameter/Equipment
Range CMC2, 5 (±) Comments
Time Interval3 – Measure
(5 to 3600) s
0.23 s
Stopwatch
1 This laboratory offers commercial calibration and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards of nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the best uncertainty due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 Fluke/Honeywell 2020 CMCs based upon 1-year manufacturer’s floor specifications at 23 °C ± 5 °C.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eit her a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | 11.5 to 90 % RH |
| 6 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.