Lyri Calibrations

#4 Jack Smith Plaza, Eight Mile Rock, Freeport, Grand Bahama, Bahamas, Freeport, Grand Bahama, Bahamas

Visit website
A2LA 7608.01ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 7608.01 · 6 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7608.01) 06/09/2026 Page 2 of 5 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current – Generate & Measure3 Up to 24 mA 0.02 % of rdg + 2 counts Fluke 725 process calibrator Electrical Simulation of Thermocouple3 Type J Type K Type T (-200 to 0) °C (0 to 1200) °C (-200 to 0) °C (0 to 1370) °C (-200 to 0) °C (0 to 400) °C 1.0 °C 0.70 °C 1.2 °C 0.80 °C 1.0 °C 0.80 °C Fluke 725 process calibrator II. Fluid Quantities Parameter/Equipment Range CMC2, 4 (±) Comments Air Velocity – Measuring Equipment3 (0.40 to 10.00) m/s (10.0 to 25.00) m/s (80 to 1965) ft/min (1965 to 4900) ft/min 0.5 meters/sec 0.75 meters/sec 100 ft/min 150 ft/min Anemometer
3-Cardiac Functions; Ventilators; Anesthesia Machines; Defibrillators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7608.01) 06/09/2026 Page 3 of 5 III. Mechanical Parameter/Equipment Range CMC2 (±) Comments Cardiac Functions – Measure3 ECG Tests Pacemaker Signals Arrhythmia Function Blood Pressure Function Cardiac Output Fetal/Maternal Function Pulse Oximeter 0.05 mV to 5 V 0.1 mV to 10 V / (30-240) bpm (30 to 300) bpm Up to 300 mmHg Up to 20 L/min (30 to 240) bpm (70 – 100) % SpO2 0.15 % rdg + 5 µV 0.2 % rdg + 10 µV 0.1 bpm 0.5 mmHg 2 % rdg 0.1 bpm 1 % SpO2 Fluke PROSIM 3 PROSIM SPOT SP02 Ventilators3 Flow Volume Pressure Temperature Humidity Up to 200 slpm Up to 100 L (-0.8 to 10) bar Up to 50 °C Up to 100 % RH 2 % rdg 2 % rdg 1 % rdg 0.5 °C 3 % RH VT900A/Vapor Anesthesia Machines3 Flow Volume Pressure O2 Concentration Up to 200 slpm Up to 100 L (-0.8 to 10) bar Up to 100 % 2 % rdg 2 % rdg 1 % rdg 1 % rdg VT900A/Vapor Defibrillators3 Energy Voltage Current Pulse Width (1 to 360) J (20 to 5000) V (0.4 to 100) A (1 to 50) ms 1.5 % rdg + 0.3 J 1 % rdg + 2 V 2 % rdg + 0.1 A 0.1 ms Impulse 7000DP
See scope document
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7608.01) 06/09/2026 Page 4 of 5 IV. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Thermometers3 (-200 to 200) °C (100 to 1100) °C 1.1 °C 2.0 °C Type J, K, T, bath V. Time & Frequency Parameter/Equipment Range CMC2, 4 (±) Comments Frequency – Measure3 (2 to 1000) CPM (1 to 1100) Hz (1 to 10) kHz Sensitivity 0.05 % rdg + 1 count 0.05 % rdg + 1 count 0.05 % rdg + 1 count 1 V peak-to-peak minimum Fluke 725 process calibrator ________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the la boratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7608.01) 06/09/2026 Page 5 of 5 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
6ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .