Registers refreshed 2026-11-08.See refresh dates
Italy

Sistema Ambiente

Via del Commercio 8, 06132, Perugia, Italy

Visit website
ACCREDIA 01339ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
17
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 17 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.

EPA9
EPA 3015
EPA 3051
EPA 5021Volatile Organic Compounds (VOCs) in Various Sample Matrices Using Equilibrium Headspace Analysis
EPA 5030Purge-and-Trap for Aqueous Samples
EPA 5035
EPA 6010Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)
EPA 8015Nonhalogenated Organics by Gas Chromatography
EPA 8260Volatile Organic Compounds by Gas Chromatography/Mass Spectrometry
EPA 9045
ISO5
ISO 9377-2Water quality - Determination of hydrocarbon oil index - Part 2: Method using solvent extraction and gas chromatography
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 16703Soil quality - Determination of content of hydrocarbon in the range C10 to C40 by gas chromatography
ISO 23695Water quality - Determination of ammonium nitrogen in water - Small-scale sealed tube method
Other standards3
APAT CNR IRSA 2060 Man 29 2003pH
EN 14039Characterization of waste - Determination of hydrocarbon content in the range of C10 to C40 by gas chromatography
EN 17322Environmental Solid Matrices - Determination of polychlorinated biphenyls (PCB) by gas chromatography - mass selective detection (GC-MS) or electron-capture detection (GC-ECD)Exclusion

Limits written next to it

UNI EN 17322:2020 - escluso/except

Exclusion. Written next to it on line 3 of ACCREDIA certificate 01339.

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.

Scope as published by ACCREDIA

4 lines
ACCREDIA

ISO/IEC 17025

Active

01339

View scope

Accredited scope, certificate 01339

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; UNI EN ISO 9377-2:2002; UNI ISO 23695:2023; UNI EN ISO 10304-1:2009; EPA 5030C 2003; EPA 8260D 2018Waste waterSee scope document
2UNI CEI EN ISO/IEC 17025:2018; EPA 6010D 2018; APAT CNR IRSA 2090 B Man 29 2003; EPA 5030C 2003; EPA 8260D 2018; ISO 15705:2002; EPA 3015A 2007; EPA 6010D 2018; EPA 9045D 2004; UNI EN 14039:2005; UNI 10780:1998 App K; UNI 11184:2016; UNI EN ISO 16703:2011Waste water1 to 13
3UNI CEI EN ISO/IEC 17025:2018; UNI EN 17322:2020; EPA 5035A 2002; EPA 8260D 2018; CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008; EPA 5021A 2014; EPA 8015C 2007; EPA 3051A 2007; EPA 6010D 2018; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1Soil-
4

Extracted from the scope document; tables may not line up. View scope for the original.

Sistema Ambiente Srl Via del Commercio 8 06132 Perugia PG Legenda/Note Allegato al certificato di accreditamento n. 01339 rev. 4 del 17/09/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 15 Sede A Data: 29/12/2025 pag. 4 di 4 Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not provided for by the method but acceptable Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title, see ACCREDIA General Regulation RG-02. Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the accreditation certificate issued to the laboratory. L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions and interpretations based on the results of the specific marked tests. L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that a suspension of accreditation is active for the specific activity shown next to it.

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via del Commercio 8, Perugia, 06132, IT

43.26422, 12.38282

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.