Modern Machine & Tool
11844 Jefferson Ave., 23606, Newport News, VA, United States
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 2836.01 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2836.01) 05/15/2025 Page 1 of 5
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
MODERN MACHINE & TOOL CO., INC.
11844 Jefferson Avenue
Newport News, VA 23606-2587
Stephen Watson Phone: (757) 873-8224
CALIBRATION
Valid To: April 30, 2027 Certificate Number: 2836.01
In recognition of the successful completion of the A2 LA evaluation process, (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requir ements) accreditation is
granted to this laboratory to perform the following calibrations
1, 8:
I. Dimensional
Parameter/Equipment
Range
CMC
2, 7 (±)
Comments
Micrometers –
Outside:
0.0001 in Increments
0.001 in Increments
Inside
Depth
Micrometers Standards
Thread Micrometers
Up to 12 in
Up to 24 in
(1 to 11) in
Up to 12 in
(1 to 11) in
(11 to 48) in
Up to 5 in
0.000 13 in
0.000 73 in
0.000 17 in
0.0012 in
0.000 59 in
0.000 86 in
0.0012 in
Length standards
60° standards
Gage Blocks
(0.05 to 20) in
0.000 15 in
Length standards
Plain Plugs
Up to 4 in 0.000 11 in
Height master
Pin Gages
Up to 4 in 0.000 25 in
Height master | ||
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2836.01) 05/15/2025 Page 2 of 5
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Indicators
0.0001 in Increments
0.001 in Increments
Up to 12 in
0.000 15 in
0.0012 in
Height master
Calipers
Up to 12 in
0.0012 in
Length standards
Sine Plate
Up to 24 in 0.0017°
CMM, gage blocks
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 10 (±)
Comments
DC Voltage
3 – Measure
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
11 µV/V + 0.4 µV
10 µV/V + 0.4 µV
10 µV/V + 0.6 µV
12 µV/V + 40 µV
Agilent 3458A
DC Voltage
3 – Generate
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
11 µV/V + 0.4 µV
10 µV/V + 0.4 µV
10 µV/V + 0.6 µV
12 µV/V + 40 µV
Fluke 5440B with
Agilent 3458A
DC Current
3 – Measure
(0 to 100) nA
101 nA to 1 µA
(1 to 10) µA
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
44 µA/A + 45 pA
27 µA/A + 45 pA
27 µA/A + 110 pA
24 µA/A + 0.9 nA
24 µA/A + 6 nA
24 µA/A + 60 nA
41 µA/A + 600 nA
0.013 % + 12 µA
Agilent 3458A
DC Current
3 – Generate
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
24 µA/A + 0.9 nA
24 µA/A + 6 nA
24 µA/A + 60 nA
41 µA/A + 600 nA
0.013 % + 12 µA
Fluke 5100B with
Agilent 3458A | to 12 in |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2836.01) 05/15/2025 Page 3 of 5
Parameter/Equipment
Range
CMC2, 10 (±)
Comments
Resistance
3 – Measure
(0 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(100 to 1000) MΩ
18 µΩ/Ω + 60 µΩ
14 µΩ/Ω + 0.6 mΩ
12 µΩ/Ω + 0.6 mΩ
12 µΩ/Ω + 6 mΩ
12 µΩ/Ω + 60 mΩ
18 µΩ/Ω + 3 Ω
89 µΩ/Ω + 110 Ω
0.078 % + 1.2 kΩ
0.058 % + 12 kΩ
Agilent 3458A
Resistance
3 – Generate
(1 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
18 µΩ/Ω + 60 µΩ
14 µΩ/Ω + 0.6 mΩ
12 µΩ/Ω + 0.6 mΩ
12 µΩ/Ω + 6 mΩ
12 µΩ/Ω + 60 mΩ
18 µΩ/Ω + 3 Ω
89 µΩ/Ω + 110 Ω
0.078 % + 1.2 kΩ
Agilent 3458A with
Fluke 5450A
III. Fluid Quantities
Parameter/Equipment
Range
CMC2 (±)
Comments
Viscosity Cups –
G10
G20
G35
G60
G100
G200
G350
17.71 cts
34.07 cts
64.77 cts
117.7 cts
228.2 cts
396.8 cts
715.7 cts
0.29 s
0.20 s
0.16 s
0.17 s
0.19 s
0.26 s
0.28 s
Thermometer, stop
watch, viscosity oils | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2836.01) 05/15/2025 Page 4 of 5
IV. Mechanical
Parameter/Equipment
Range
CMC2, 4, 5, 6, 9 (±)
Comments
Torque Wrenches
(6 to 23) lbfꞏin
(24 to 240) lbfꞏin
(5 to 59) lbfꞏft
(60 to 600) lbfꞏft
(200 to 2000) lbfꞏft
(500 to 5000) lbfꞏft
0.2 % + 0.6R
0.1 % + 0.6R
0.2 % + 0.6R
0.1 % + 0.6R
0.1 % + 0.6R
0.15 % + 0.6R
Torque cell
Torque Sensors
(0.02 to 20 000) lbfꞏft
0.012 % IV
Class F weights & arms
Pressure Gages
(4 to 600) inꞏH
2O
(1 to 300) psi
(5 to 10 000) psi
0.2 %
0.1 %
0.1 %
Ametek RK
Ametek RK
Mansfield green
Force, Tension, &
Compression
3 –
Measuring Equipment
Up to 32 000 lbf
(30 to 2000) lbf
(200 to 10 000) lbf
(500 to 25 000) lbf
(1000 to 50 000) lbf
(2000 to 100 000) lbf
0.012 % IV
0.027 % FS
0.017 % FS
0.016 % FS
0.016 % FS
0.014 % FS
Class F weights
Load cells
Scales & Balances3
1 mg to 100 g
100 g to 1 kg
(1 to 100) kg
(0.01 to 2000) lb
(2001 to 30 000) lb
0.040 mg + 0.6R
0.013 g + 0.6R
0.017 g + 0.6R
0.013 % FS + 0.6R
0.013 % FS + 0.6R
Class 1 weights
Class 1 & F weights
Mass
1 mg to 205 g
(206 to 5000) g
(5001 to 64 000) g
(200 to 2000) lb
0.000 04 g
0.013 g
0.17 g
0.013 % FS
Comparison with mass
standards
Analytical balance
Load cell | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2836.01) 05/15/2025 Page 5 of 5
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 9 (±)
Comments
Temperature – Measure
32 F
32 F, 70 F, 100 F
(122 to 220) °F
(220 to 400) °F
(400 to 750) °F
0.3 °F
0.3 °F
0.3 °F
0.66 °F
1.2 °F
Ice bath
Thermometer
(Comparisons w/ liquid
filled thermometers)
Dri-block calibrator
___________________________________________
1
This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, percentages are to be read as percent of reading, unless otherwise noted.
5 In the statement of CMC, “FS” represents “full scale” and “IV” represents “indicated value.”
6 In the statement of CMC, R is the resolution of the unit under test.
7 The contributions from the “best existing device” are not included in the CMC claim.
8 This scope meets A2LA’s P112 Flexible Scope Policy.
9 The type of instrument or material being calibrate d is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
10 The stated measured values are determined usi ng the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification. | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
MODERN MACHINE & TOOL CO., INC.
Newport News, VA
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements
for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration
Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 15th day of May 2025.
__ _____________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2836.01
Valid to April 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.