What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 13 scope lines.

DAKKS certificate D-PL-18779-01-00 · 3 lines

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001Scene of crime samples; Reference samples-
2In-house methodhuman DNA from: human material, forensic traces and tissue samples; Human DNA from: buccal swabs, blood; buccal swabs, blood, saliva, human materials, forensic traces and tissue samples; human biological material-
3STR-analysis: PCR followed by electrophoresis and allelic mapping of PCR productshuman DNA from: cell culture samples-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS certificate D-PL-18779-01-01 · 3 lines

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-18779-01-01 Gültig ab: 15.06.2026 Ausstellungsdatum: 15.06.2026 Seite 2 von 3 Prüfungen im Bereich: Forensik Prüfgebiete: 1 Forensische Genetik ............................. ............................................................................................. 3 Verwendete Abkürzungen:........................................................................................................................ 3 Flexibler Akkreditierungsbereich: Dem Prüflaboratorium ist innerhalb der gekennzeichneten Prüfbereiche, ohne dass es einer vorherigen Information und Zustimmung der DAkkS bedarf, [Flex C] die Modifizierung sowie Weiter- und Neuen twicklung von Prüfverfahren gestattet . Die aufgeführten Prüfverfahren sind beispielhaft. Das Prüflaboratorium verfügt über eine aktuelle Liste aller Prüfverfahren im flexiblen Akkreditierungsbereich. Die Liste ist öffentlich verfügbar auf der Webpräsenz des Prüflaboratoriums.
3-Human -biologisches Material; Blut; Sperma; Speichel; Haare; Gewebe; Mundschleimhaut
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-18779-01-01 Gültig ab: 15.06.2026 Ausstellungsdatum: 15.06.2026 Seite 3 von 3 1 Forensische Genetik Prüfart - Prüfmethodik/Messprinzip Analyt/ Messgröße/ Prüfparameter/ Matrix/ Testobjekt Prüfgegenstand Flexibilisierung / Prüfanweisung Probenahme Probe nahme im Rahmen der Spurenuntersuchung Human - biologisches Material [Flex C] Vortests chemische Testverfahren, immunochemische Testverfahren Blut Human - biologische Probe [Flex C] Vortests chemische Testverfahren, immunochemische Testverfahren, histochemische Färbeverfahren Sperma Human - biologische Probe [Flex C] Vortests Enzymatische Testverfahren Speichel Human - biologische Probe [Flex C] Vortests Mikroskopie Haare Human - biologische Probe [Flex C] Polymerase -Kettenreaktion mit flexiblen Reagenzien DNA-Extraktion, Quantifizierung mit RT-PCR, STR-PCR, Elektrophorese, allelische Zuordnung der PCR-Produkte Genotyp zur Spurenuntersuchung, Genotyp zur Vergleichsprobenuntersuch ung forensische Spuren, Gewebe, Mund- schleimhaut, Blut [Flex C] Verwendete Abkürzungen: DIN Deutsches Institut für Normung e.V. EN Europäische Norm IEC International Electrotechnical Commission – Int ernationale Elektrotechnische Kommission ISO International Organization for Standardization – Internationale Organisation für Normung PCR polymerase chain reaction RT Real Timeüß STR Short tandem repeats
-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS certificate D-PL-18779-01-02 · 2 lines

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2-humane DNA aus: Zellkulturproben
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-18779-01-02 Nukleinsäureanalytik Nukleinsäure-Amplifikation (inkl. Aufreinigung und Anreicherung) [Flex C] Analyt (Meßgröße) Prüfgegenstände (Matrix) Prüftechnik Anweisung/Version Genotyp zu Zelllinien- charakterisierung humane DNA aus: Zellkulturproben DNA-Extraktion, STR- Analyse: PCR mit anschließender Elektrophorese und allelischer Zuordnung der PCR-Produkte SOP_FOR_Zelllinien_3.0 verwendete Abkürzungen: DIN Deutsches Institut für Normung e.V. DNA Deoxyribonucleic acid EN Europäische Norm IEC International Electrotechnical Commission ISO International Organization for Standardization PCR polymerase chain reaction STR Short tandem repeats SOP_FOR Hausverfahren der KBS Flexibler Akkreditierungsbereich: Dem Prüflaboratorium ist innerhalb der gekennzeichneten Prüfbereiche, ohne dass es einer vorherigen Information und Zustimmung der DAkkS bedarf, [Flex C] die Modifizierung sowie Weiter- und Neuentwicklung von Prüfverfahren gestaBet. Die aufgeführten Prüfverfahren sind beispielhaft. Das Prüflaboratorium verfügt über eine aktuelle Liste aller Prüfverfahren im flexiblen Akkreditierungsbereich. Die Liste ist öffentlich verfügbar auf der Webpräsenz des Prüflaboratoriums. Gültig ab: 15.06.2026 Ausstellungsdatum: 15.06.2026 Seite 2 von 2
-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS certificate D-PL-18779-02-00 · 2 lines

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001--
2In-house methodHuman DNA from: buccal swabs, blood, saliva, tissue; Human mitochondrial DNA from: buccal swabs, blood, saliva; buccal swabs, blood, tissue-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS certificate D-PL-18779-02-01 · 3 lines

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-18779-02-01 Gültig ab: 15.06.2026 Gültig bis: 14.06.2031 Ausstellungsdatum: 15.06.2026 Seite 2 von 3 Prüfungen im Bereich: Forensik Prüfgebiete: 1 Forensische Genetik ............................. ............................................................................................. 3 Verwendete Abkürzungen:........................................................................................................................ 3 Flexibler Akkreditierungsbereich: Dem Prüflaboratorium ist innerhalb der gekennzeichneten Prüfbereiche, ohne dass es einer vorherigen Information und Zustimmung der DAkkS bedarf, [Flex C] die Modifizierung sowie Weiter- und Neuen twicklung von Prüfverfahren gestattet . Die aufgeführten Prüfverfahren sind beispielhaft. Das Prüflaboratorium verfügt über eine aktuelle Liste aller Prüfverfahren im flexiblen Akkreditierungsbereich. Die Liste ist öffentlich verfügbar auf der Webpräsenz des Prüflaboratoriums.
3GenDGBlut; Mundschleimhaut; Gewebe; Speichel-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Anzinger Straße 7a, Ebersberg, 85560, DE

48.09582, 11.96123

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.