Consolidated Controls
3620 Busch Dr. SW, 49418, Grandville, MI, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 1375.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 12 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1375.01) 08/21/2024 Page 2 of 3
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 5 (±) Comments
DC Voltage – Generate3
(-99.900 to 99.900) mV
(-30.00 to 30.00) V
0.03 mV
0.031 V
Yokogawa 7651
Yokogawa 7651
Electrical Simulation and
Measure of Temperature
Indicating Systems3 –
Type E T/C
Type J
Type K
Type N
Type R
Type S
Type T
(-50 to 1000) °F
(-50 to 1400) °F
(-50 to 2400) °F
(-50 to 1800) °F
(100 to 3100) °F
(100 to 3100) °F
(-50 to 700) °F
0.41 °F
0.41 °F
0.51 °F
0.52 °F
1.2 °F
1.4 °F
0.42 °F
Yokogawa 7651
Temperature – Measure3
Type J
Type K
Type N
Type R
Type T
Other Probe Types
(32 to 1400) °F
(32 to 2400) °F
(32 to 1800) °F
(100 to 3100) °F
(32 to 700) °F
(32 to 2000) °F
1.8 °F
1.8 °F
1.8 °F
2.3 °F
1.8 °F
2.3 °F
PIE 422 and standard
thermocouples
IR Thermometers –
Measuring Equipment
(100 to 2200) °F
4.7 °F
Ircon Model BCH-
22F-1 &PIE 422 w/
probe
Ɛ = (0.99) | -99.9 to 99.9 mV |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1375.01) 08/21/2024 Page 3 of 3
III. Mechanical
Parameter/Equipment
Range CMC2 (±) Comments
Pressure – Measuring
Equipment & Measure
Hydraulic Gage3
(0 to 5000) psi
2.6 psig
UPS 3000AAA
IV. Thermodynamics
Parameter/Equipment
Range CMC2, 5 (±) Comments
Relative Humidity –
Measure3
(20 to 80) % RH
2.6 % RH
Vaisala HMP110
____________________
1 This laboratory offers commercial calibration service and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by the transportation of the calibration
equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g.
resolution) must also be considered and this, on its own, could result in the actual measurement
uncertainty achievable on a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 The contributions from the “best existing device” are not included in the CMC claim. | 0 to 5000 psi |
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- MetroCalKentwood, MI · ~11 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Howmet Research CenterWhitehall, MI · ~73 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- International Certification Measurements, Inc. (subsidiary of Leader Corporation)Shelby Township, MI · ~90 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Consumers Energy/Laboratory ServicesJackson, MI · ~132 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - DetroitHowell, MI · ~153 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994