Consolidated Controls

3620 Busch Dr. SW, 49418, Grandville, MI, United States

Visit website
A2LA 1375.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 1375.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 12 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1375.01) 08/21/2024 Page 2 of 3 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Generate3 (-99.900 to 99.900) mV (-30.00 to 30.00) V 0.03 mV 0.031 V Yokogawa 7651 Yokogawa 7651 Electrical Simulation and Measure of Temperature Indicating Systems3 – Type E T/C Type J Type K Type N Type R Type S Type T (-50 to 1000) °F (-50 to 1400) °F (-50 to 2400) °F (-50 to 1800) °F (100 to 3100) °F (100 to 3100) °F (-50 to 700) °F 0.41 °F 0.41 °F 0.51 °F 0.52 °F 1.2 °F 1.4 °F 0.42 °F Yokogawa 7651 Temperature – Measure3 Type J Type K Type N Type R Type T Other Probe Types (32 to 1400) °F (32 to 2400) °F (32 to 1800) °F (100 to 3100) °F (32 to 700) °F (32 to 2000) °F 1.8 °F 1.8 °F 1.8 °F 2.3 °F 1.8 °F 2.3 °F PIE 422 and standard thermocouples IR Thermometers – Measuring Equipment (100 to 2200) °F 4.7 °F Ircon Model BCH- 22F-1 &PIE 422 w/ probe Ɛ = (0.99)
-99.9 to 99.9 mV
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1375.01) 08/21/2024 Page 3 of 3 III. Mechanical Parameter/Equipment Range CMC2 (±) Comments Pressure – Measuring Equipment & Measure Hydraulic Gage3 (0 to 5000) psi 2.6 psig UPS 3000AAA IV. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Relative Humidity – Measure3 (20 to 80) % RH 2.6 % RH Vaisala HMP110 ____________________ 1 This laboratory offers commercial calibration service and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by the transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 The contributions from the “best existing device” are not included in the CMC claim.
0 to 5000 psi
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.