MDI Calibration

6065 NW 167 ST, Suite B9, 33015, Hialeah, FL, United States

Visit website
A2LA 5672.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 5672.01 · 6 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5672.01) 11/21/2025 Page 1 of 5 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MDI CALIBRATION 6065 NW 167 St, Suite B9 Hialeah, FL 33015 Daylen Torres Phone: 305 362 2849 CALIBRATION Valid To: October 31, 2027 Certificate Number: 5672.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Micrometers Up to 6 in (60 + 15L) μin Gage blocks Calipers Up to 12 in (700 + 0.4L) μin Gage blocks & surface plates Indicators Up to 2 in (130 + 3L) μin Gage blocks & transfer stand Depth Gages Up to 12 in (700 + 0.4L) μin Gage blocks
to 6 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5672.01) 11/21/2025 Page 2 of 5 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 3 (±) Comments DC Voltage – Generate Up to 330 mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1000) V 6.1 µV + 55 nV/mV 50 µV + 41 µV /V 510 µV + 40 µV/V 5 mV + 45 µV/V 53 mV + 30 µV/V Fluke calibrator 5502A DC Voltage – Measure Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V 100 V to 1 kV 4 μV + 60 nV/mV 10 μV + 50 μV/V 100 μV + 40 μV/V 1 mV + 51 μV/V 15 mV + 50 μV/V Agilent 34401A DC Current – Generate Up to 330 µA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 300 mA to 3.0 A (3.0 to 11) A (10.5 to 20) A 25 nA + 160 pA/ µA 75 nA + 130 nA/mA 560 nA + 100 nA/mA 6 µA + 100 nA/mA 160 µA + 360 µA/A 800 µA + 600 µA/A 3.0 mA + 1 mA/A Fluke calibrator 5502A DC Current – Measure Up to 10 mA (10 to 100) mA (0.1 to 1) A (1 to 3) A 2 μA + 600 nA/mA 6 μA + 0.6 μA/mA 120 μA + 1.2 mA/A 700 μA + 1.4 mA/A Agilent 34401A Resistance ‒ Generate (33 to 330) Ω 330 Ω to 3.3 kΩ (3.3 to 33) kΩ (33 to 330) kΩ 330 kΩ to 3.3 MΩ (3.3 to 33) MΩ (33 to 330) MΩ 2 mΩ + 500 µΩ/Ω 53 mΩ + 100 µΩ/Ω 1.1 Ω + 80 µΩ/Ω 5 Ω + 120 µΩ/Ω 20 Ω + 200 µΩ/Ω 190 Ω + 1 mΩ/Ω 860 kΩ + 4 mΩ/Ω Fluke calibrator 5502A
to 1000 V
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5672.01) 11/21/2025 Page 3 of 5 Parameter/Equipment Range CMC2, 3 (±) Comments Resistance – Measure (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 5 mΩ + 120 μΩ/Ω 16 mΩ + 120 μΩ/Ω 150 mΩ + 120 mΩ/kΩ 2 Ω + 120 mΩ/kΩ 20 Ω + 110 Ω/MΩ 260 Ω + 450 Ω/MΩ 12 kΩ + 9 kΩ/MΩ Agilent 34401A Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage– Generate (30 to 320) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1020) V 45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 25 µV + 300 nV/mV 90 µV + 300 µV/V 930 µV + 300 µV/V 7 mV + 500 µV/V 35 mV + 500 µV/V Fluke calibrator 5502A AC Voltage – Measure Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 750) V 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 50 Hz to 1 kHz 50 μV + 860 nV/V 340 μV + 850 μV/V 3.5 mV + 850 μV/V 35 mV + 850 μV/V 260 mV + 700 μV/V Agilent 34401A AC Current – Generate (33 to 330) µA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 3.3 A (3.3 to 10.5) A (11 to 20.5) A 44 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 250 nA + 1.0 nA/µA 2.1 µA + 630 nA/mA 20 µA + 500 nA/mA 30 µA + 400 nA/mA 170 µA + 600 µA/A 2.2 mA + 1.0 mA/A 6.0 mA + 1.6 mA/A Fluke calibrator 5502A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5672.01) 11/21/2025 Page 4 of 5 Parameter/Range Frequency CMC2, 3 (±) Comments AC Current – Measure (0.1 to 1) A (1 to 3) A 20 Hz to 1 kHz 40 Hz to 1 kHz 450 μA + 1.3 mA/A 3.5 mA + 4 mA/A Agilent 34401A III. Mechanical Parameter/Equipment Range CMC2 (±) Comments Torque Wrenches (5 to 50) ozf·in (4 to 50) lbf·in (30 to 400) lbf·in (80 to 1000) lbf·in (25 to 250) lbf∙ft 0.47 ozf·in 0.21 lbf·in 0.98 lbf·in 2.8 lbf·in 2.8 lbf·ft Torque calibrator & transducers CDI 2000-400-02 CDI 2000-4-02 IV. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment 100 Hz to 100 kHz 0.33 mHz + 0.12 mHz/Hz Fluke calibrator 5502A Frequency – Measure 40 Hz to 300 kHz 6 mHz + 120 μHz/Hz Agilent 34401A ______________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or n early ideal measuring equipment. CMC’ s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5672.01) 11/21/2025 Page 5 of 5 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
6ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

6065 NW 167 ST, Suite B9, Hialeah, FL, 33015, US

25.82678, -80.28140

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.