MDI Calibration
6065 NW 167 ST, Suite B9, 33015, Hialeah, FL, United States
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 5672.01 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5672.01) 11/21/2025 Page 1 of 5
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
MDI CALIBRATION
6065 NW 167 St, Suite B9
Hialeah, FL 33015
Daylen Torres Phone: 305 362 2849
CALIBRATION
Valid To: October 31, 2027 Certificate Number: 5672.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Dimensional
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Micrometers
Up to 6 in
(60 + 15L) μin
Gage blocks
Calipers
Up to 12 in
(700 + 0.4L) μin
Gage blocks & surface
plates
Indicators
Up to 2 in
(130 + 3L) μin
Gage blocks & transfer
stand
Depth Gages
Up to 12 in
(700 + 0.4L) μin
Gage blocks | to 6 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5672.01) 11/21/2025 Page 2 of 5
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Voltage – Generate
Up to 330 mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
6.1 µV + 55 nV/mV
50 µV + 41 µV /V
510 µV + 40 µV/V
5 mV + 45 µV/V
53 mV + 30 µV/V
Fluke calibrator
5502A
DC Voltage – Measure
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
100 V to 1 kV
4 μV + 60 nV/mV
10 μV + 50 μV/V
100 μV + 40 μV/V
1 mV + 51 μV/V
15 mV + 50 μV/V
Agilent 34401A
DC Current – Generate
Up to 330 µA
330 µA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
300 mA to 3.0 A
(3.0 to 11) A
(10.5 to 20) A
25 nA + 160 pA/ µA
75 nA + 130 nA/mA
560 nA + 100 nA/mA
6 µA + 100 nA/mA
160 µA + 360 µA/A
800 µA + 600 µA/A
3.0 mA + 1 mA/A
Fluke calibrator
5502A
DC Current – Measure
Up to 10 mA
(10 to 100) mA
(0.1 to 1) A
(1 to 3) A
2 μA + 600 nA/mA
6 μA + 0.6 μA/mA
120 μA + 1.2 mA/A
700 μA + 1.4 mA/A
Agilent 34401A
Resistance ‒ Generate
(33 to 330) Ω
330 Ω to 3.3 kΩ
(3.3 to 33) kΩ
(33 to 330) kΩ
330 kΩ to 3.3 MΩ
(3.3 to 33) MΩ
(33 to 330) MΩ
2 mΩ + 500 µΩ/Ω
53 mΩ + 100 µΩ/Ω
1.1 Ω + 80 µΩ/Ω
5 Ω + 120 µΩ/Ω
20 Ω + 200 µΩ/Ω
190 Ω + 1 mΩ/Ω
860 kΩ + 4 mΩ/Ω
Fluke calibrator
5502A | to 1000 V |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5672.01) 11/21/2025 Page 3 of 5
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Resistance – Measure
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
5 mΩ + 120 μΩ/Ω
16 mΩ + 120 μΩ/Ω
150 mΩ + 120 mΩ/kΩ
2 Ω + 120 mΩ/kΩ
20 Ω + 110 Ω/MΩ
260 Ω + 450 Ω/MΩ
12 kΩ + 9 kΩ/MΩ
Agilent 34401A
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage– Generate
(30 to 320) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
45 Hz to 10 kHz
45 Hz to 10 kHz
45 Hz to 10 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
25 µV + 300 nV/mV
90 µV + 300 µV/V
930 µV + 300 µV/V
7 mV + 500 µV/V
35 mV + 500 µV/V
Fluke calibrator
5502A
AC Voltage – Measure
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 750) V
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
50 Hz to 1 kHz
50 μV + 860 nV/V
340 μV + 850 μV/V
3.5 mV + 850 μV/V
35 mV + 850 μV/V
260 mV + 700 μV/V
Agilent 34401A
AC Current – Generate
(33 to 330) µA
330 µA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 3.3 A
(3.3 to 10.5) A
(11 to 20.5) A
44 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
250 nA + 1.0 nA/µA
2.1 µA + 630 nA/mA
20 µA + 500 nA/mA
30 µA + 400 nA/mA
170 µA + 600 µA/A
2.2 mA + 1.0 mA/A
6.0 mA + 1.6 mA/A
Fluke calibrator
5502A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5672.01) 11/21/2025 Page 4 of 5
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Measure
(0.1 to 1) A
(1 to 3) A
20 Hz to 1 kHz
40 Hz to 1 kHz
450 μA + 1.3 mA/A
3.5 mA + 4 mA/A
Agilent 34401A
III. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Torque Wrenches
(5 to 50) ozf·in
(4 to 50) lbf·in
(30 to 400) lbf·in
(80 to 1000) lbf·in
(25 to 250) lbf∙ft
0.47 ozf·in
0.21 lbf·in
0.98 lbf·in
2.8 lbf·in
2.8 lbf·ft
Torque calibrator &
transducers
CDI 2000-400-02
CDI 2000-4-02
IV. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Frequency – Measuring
Equipment
100 Hz to 100 kHz
0.33 mHz + 0.12 mHz/Hz
Fluke calibrator
5502A
Frequency – Measure
40 Hz to 300 kHz
6 mHz + 120 μHz/Hz
Agilent 34401A
______________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or n early ideal measuring equipment. CMC’ s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration. | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5672.01) 11/21/2025 Page 5 of 5
3 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 6 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.