Registers refreshed 2026-11-08.See refresh dates
France

LACQ GROUPE GEOTEC

17, impasse François de MAHY, 97430, LE TAMPON (LA REUNION), France

COFRAC 1-2359ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
4
COFRAC certificate
1
Site in our directory
1
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 4 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 12350-2Testing fresh concrete - Part 2: Slump-test
EN 12350-5
EN 12390-3Testing hardened concrete - Part 3: Compressive strength of test specimens
EN 12390-6

Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-06.

Scope as published by COFRAC

2 lines
COFRAC

ISO/IEC 17025

Active

1-2359

The scope document we hold says it is valid until 2030-04-30.

View scope

Accredited scope, certificate 1-2359

LineMethodMatrixRange
1-BETON, CIMENT, MORTIER, COULIS ET CONSTITUANTS (ADDITIONS, ADJUVANTS, PRODUITS SPECIAUX, PRODUITS DE CURE); CONCRETE, CEMENT, MORTAR, GROUT AND COMPONENTS (ADDITIONS, ADMIXTURES, SPECIAL PRODUCTS)
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Convention N° 3510 LAB FORM 37 – Révision 09 – applicable au 15 octobre 2022 Page 1/5 Section Laboratoires ATTESTATION D’ACCREDITATION ACCREDITATION CERTIFICATE N° 1-2359 rév. 9 Le Comité Français d'Accréditation (Cofrac) atteste que : The French Committee for Accreditation (Cofrac) certifies that : LACQ N° SIREN : 478257678 Satisfait aux exigences de la norme NF EN ISO/IEC 17025 : 2017 Fulfils the requirements of the standard et aux règles d’application du Cofrac pour les activités d’analyses/essais/étalonnages en : and Cofrac rules of application for the activities of testing/calibration in : BATIMENT ET GENIE CIVIL / ELEMENTS DE CONSTRUCTION - BETON, CIMENT, MORTIER, COULIS ET CONSTITUANTS (ADDITIONS, ADJUVANTS, PRODUITS SPECIAUX, PRODUITS DE CURE) BUILDING AND CIVIL ENGINEERING / CONSTRUCTION COMPONENTS - CONCRETE, CEMENT, MORTAR, GROUT AND COMPONENTS (ADDITIONS, ADMIXTURES, SPECIAL PRODUCTS) réalisées par / performed by : LACQ Groupe GEOTEC 17, impasse François de MAHY 97430 LE TAMPON (LA REUNION) et précisément décrites dans l’annexe technique jointe and precisely described in the attached technical appendix L’accréditation suivant la norme internationale homologuée NF EN ISO/IEC 17025 est la preuve de la compétence technique du laboratoire dans un domaine d’activités clairement défini et du bon fonctionnement dans ce laboratoire d’un système de management adapté (cf. communiqué conjoint ISO- ILAC-IAF en vigueur disponible sur le site internet du Cofrac www.cofrac.fr) Accreditation in accordance with the recognised international standard NF EN ISO/IEC 17025 demonstrates the technical competence of the laboratory for a defined scope and the proper operation in this laboratory of an appropriate management system (see current Joint ISO -ILAC-IAF Communiqué available on Cofrac web site www.cofrac.fr) . Le Cofrac est signataire de l’accord multilatéral d’EA pour l’accréditation , pour les activités objets de la présente attestation. Cofrac is signatory of the European co -operation for Accreditation (EA) Multilateral Agreement for accreditation for the activities covered by this certificate. Date de prise d’effet / granting date : 01/05/2025 Date de fin de validité / expiry date : 30/04/2030
-
2NF EN 12350-2; NF EN 12350-5; NF EN 12390-3; NF EN 12390-6Béton frais; Béton durci-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

17, impasse François de MAHY, LE TAMPON (LA REUNION), 97430, FR

-21.27348, 55.50586

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.