Registers refreshed 2026-11-20.See refresh dates
Malaysia

Sony EMCS EMC/RF Test Laboratory, KL Branch

Lot 5, Jalan Kemajuan, Bangi Industrial Estate, 43650 Bandar Baru Bangi, Selangor, 43650, Malaysia, Selangor, Malaysia

A2LA 3203.05ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
10
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 10 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.

ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement

Certificate says EN 55013. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

VCCI-CISPR 32probably the same standard; matched by number only

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

ETSI EN 301 489-1Exclusion

Limits written next to it

EN 301489-1 (excluding vehicular testing)

Exclusion. Written next to it on line 1 of A2LA certificate 3203.05.

EN 301489-1 V2.2.3 (2019-11) (excluding vehicular testing)

Exclusion. Written next to it on line 1 of A2LA certificate 3203.05.

ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 303 340
ETSI EN 303 372-2
FCC PART 15Radio Frequency Devices

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

3203.05

The scope document we hold says it is valid until 2027-05-31.

View scope

Accredited scope, certificate 3203.05

LineMethodMatrixRange
147 CFR FCC Part 15B (using ANSI C63.4:2014); CISPR 22; EN 55022; CISPR 13; EN 55013; CISPR 32; EN 55032; CISPRJ 32:2017 (excluding Table A.7); ICES-003; SANS 2332; SANS 2332:2017; VCCI-CISPR 32:2016 (excluding Table A.7); EN 301489-1 (excluding vehicular testing); EN 301489-1 V2.2.3 (2019-11) (excluding vehicular testing); EN 301489-3; EN 301 489-3 V2.3.2 (2023-01); EN 301489-17; EN 301489-17 V3.2.4 (2020-09); EN 301 489-17 V3.3.1 (2024-09); EN 303 340; EN 303 340 V1.1.2 (2016-09); EN 303 372-2; EN 303 372-2 V1.2.1 (2021-06); CISPR 35 (excluding broadband impulsive conductive disturbances); CISPR 35: 2016 (excluding broadband impulsive conductive disturbances)-to 40 GHz
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3203.05) Revised 12/17/2025 Page 2 of 3 Test Technology: Test Method(s) 1: Generic and Product Family Standards (continued) EN 55035 (excluding broadband impulsive conductive disturbances); EN 55035: 2017 (excluding broadband impulsive conductive disturbances); EN 55035: 2017 +A11: 2020 (excluding broadband impulsive conductive disturbances); SANS 2335 (excluding F.4,H); SANS 2335:2018 (excluding F.4, H) Current Harmonics IEC 61000-3-2; IEC 61000-3-2: 2018 + A1:2020; IEC 61000-3-2: 2018+A2:2024; EN IEC 61000-3-2: 2019; EN IEC 61000-3-2: 2019 + A1: 2021; EN IEC 61000-3-2: 2019+A2:2024 SANS 61000-3-2: 2009 Voltage Fluctuations and Flicker IEC 61000-3-3; IEC 61000-3-3: 2013 + A1: 2017; IEC 61000-3-3: 2013 + A1: 2017 + A2: 2021; EN 61000-3-3: 2013 + A1: 2019; EN 61000-3-3: 2013 +A1: 2019 + A2: 2021; SANS 61000-3-3: 2009 Immunity Electrostatic Discharge IEC 61000-4-2; IEC 61000-4-2: 2008; EN 61000-4-2: 2009 Radiated Immunity IEC 61000-4-3; IEC 61000-4-3: 2006 + A1:2007 +A2: 2010; IEC 61000-4-3: 2020; EN 61000-4-3: 2006 +A1:2008+A2:2010; EN IEC 61000-4-3: 2020 Electrical Fast Transient / Burst IEC 61000-4-4; IEC 61000-4-4: 2012; EN 61000-4-4: 2012 Surge Immunity IEC 61000-4-5; IEC 61000-4-5: 2014+A1: 2017; IEC 61000-4-5: 2005; EN 61000-4-5: 2006; EN 61000-4-5: 2014 + A1:2017 Conducted Immunity IEC 61000-4-6; IEC 61000-4-6: 2008; IEC 61000-4-6: 2013; IEC 61000-4-6: 2023; EN 61000-4-6: 2009; EN 61000-4-6: 2014; EN IEC 61000-4-6: 2023 Power Frequency Magnetic Field IEC 61000-4-8 (excluding short duration mode); IEC 61000-4-8: 2009 (excluding short duration mode); EN 61000-4-8: 2010 (excluding short duration mode) Voltage Dips and Interruptions IEC 61000-4-11; IEC 61000-4-11: 2004; EN 61000-4-11: 2004; IEC 61000-4-11: 2020; EN IEC 61000-4-11: 2020 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a period of one year from the date of publication of the standard test method, per Annex A, Part C of A2LA R101 - General Requirements- Accreditation of Conformity Assessment Bodies.
3ANSI C63.4:2014-to 40000 MHz
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SONY EMCS EMC/RF TEST LABORATORY, KL BRANCH Selangor, Malaysia for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 16th day of April 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3203.05 Valid to May 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.