Registers refreshed 2026-11-20.See refresh dates
China

SHANGHAI YANFENG JINQIAO AUTOMOTIVE TRIM SYSTEMS CO.,LTD.AUTOMOTIVE TRIM & ELECTRONICS TESTING LABORATORY.

6th Building, 1001 North Qinzhou Road., Shanghai, 200233, People's Republic of China, Shanghai, China

Visit website
A2LA 2603.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
8
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 8 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-5Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 5: Stripline
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

2603.01

The scope document we hold says it is valid until 2027-11-30.

View scope

Accredited scope, certificate 2603.01

LineMethodMatrixRange
1ISO 10605 (2001, 2008, 2023); CS.00054 (2018), Section 5.10; FORD FMC1278-2021 (CI 280); GMW 3097 (2015), Section 3.6; GMW 3097 (2019), Section 3.6; GMW 3097 (2022), Section 3.6; VW TL81000 (2018), Section 5.1; VW TL81000 (2021), Section 5.1; GS 95002-2_2021, Section 6.10; GS 95002-2_2021, Section 6.11; GS 95002-2_2021, Section 6.12; CISPR 25 (2016), Sections 6.3 and 6.4; CISPR 25 (2021), Section 6.3 and 6.4; CS.00054 2018, Section 5.6.1 and 5.6.2; FORD FMC1278-2021 (CE 420); FORD FMC1278-2021 (CE 421); GMW 3097 (2015), Section 3.3.2; GMW 3097 (2019), Section 3.3.2; GMW 3097 (2022), Section 3.3.2--
2VW TL81000 (2018), Section 5.3.5; VW TL81000 (2018), Section 5.3.8; VW TL81000 (2021), Section 5.3.5; VW TL81000 (2021), Section 5.3.8; GS 95002-2_2021, Section 5.2; GS 95002-2_2021, Section 5.4; CISPR 25 (2016), Section 6.5; CISPR 25 (2021), Section 6.5; CS.00054 (2018), Section 5.6.3; FORD FMC1278-2021 (RE310); GMW 3097 (2015), Section 3.3.1; GMW 3097 (2019), Section 3.3.1; GMW 3097 (2022), Section 3.3.1; VW TL81000 (2018), Section 5.3.6; VW TL81000 (2021), Section 5.3.6; GS 95002-2_2021, Section 5.3; ISO 11452-9 (2012, 2021); FORD FMC1278-2021 (RI 115); GMW 3097 (2015), Section 3.4.4; GMW 3097 (2019), Section 3.4.4; GMW 3097 (2022), Section 3.4.4; VW TL81000 (2018), Section 5.2.5; VW TL81000 (2021), Section 5.2.5; GS 95002-2_2021, Section 6.6; ISO 7637-2 (2004, 2011); CS.00054 (2018), Section 5.7; FORD FMC1278-2021 (CE 410); GMW 3097 (2015), Section 3.5.1; GMW 3097 (2019), Section 3.5.1; GMW 3097 (2022), Section 3.5.1; VW TL81000 (2018), Section 5.4.4.2; VW TL81000 (2021), Section 5.4.3.2; GS 95002-2_2021, Section 5.9--
3ISO 11452-4 (2005, 2011, 2020); CS.00054 (2018), Section 5.8.1; FORD FMC1278-2021 (RI 112); GMW 3097 (2015), Section 3.4.1; GMW 3097 (2019), Section 3.4.1; GMW 3097 (2022), Section 3.4.1; VW TL81000 (2018), Section 5.2.2; VW TL81000 (2021), Section 5.2.2; GS 95002-2_2021, Section 6.2; GS 95002-2_2021, Section 6.3; ISO 11452-2 (2004, 2019); CS.00054 (2018), Section 5.8.2; FORD FMC1278-2021(RI 114); GMW 3097 (2015), Section 3.4.2; GMW 3097 (2019), Section 3.4.2; GMW 3097 (2022), Section 3.4.2; VW TL81000 (2018), Section 5.2.3; VW TL81000 (2021), Section 5.2.3; GS 95002-2_2021, Section 6.4; GS 95002-2_2021, Section 6.5; ISO 11452-5:2002; ISO 11452-2 (2004, 2019); FORD FMC1278-2021 (RI 114 Bands 7 & 8); GMW 3097 (2015), Section 3.4.2; GMW 3097 (2019), Section 3.4.2; GMW 3097 (2022), Section 3.4.2; GMW 3097 (2015), Section 3.3.3; GMW 3097 (2019), Sections 3.3.3 & 3.3.4; GMW 3097 (2015), Sections 3.3.3 & 3.3.4; FORD FMC1278-2021 (RE320); FORD FMC1278-2021 (RE330); VW TL81000 (2021), Sections 5.3.9 & 5.3.10 & 5.3.11; GS 95002-2_2021, Sections 5.5 & 5.6 & 5.7; GS 95002-2_2021, Section 5.8-See scope document
4ISO 11452-8 (2007); ISO 11452-8 (2015); FORD FMC1278-2021 (RI 140); GMW 3097 (2015), Section 3.4.5; GMW 3097 (2019), Section 3.4.5; GMW 3097 (2022), Section 3.4.5; VW TL81000 (2018), Section 5.2.6; VW TL81000 (2021), Section 5.2.6; GS 95002-2_2021, Section 6.7; ISO 7637-2 (2004, 2011); CS.00054 (2018), Section 5.9.1; CS.00054 (2018), Section 5.9.4; FORD FMC1278-2021(CI 220); FORD FMC1278-2021(CI 221); FORD FMC1278-2021(CI 222); GMW 3097 (2015), Section 3.5.2; GMW 3097 (2019), Section 3.5.2; GMW 3097 (2022), Section 3.5.2; VW TL81000 (2018), Section 5.4.4; VW TL81000 (2021), Section 5.4.3; GS 95002-2_2021, Section 6.8; ISO 7637-3 (2007 & 2016); CS.00054 (2018), Section 5.9.2; CS.00054 (2018), Section 5.9.3; GMW 3097 (2015), Sections 3.5.3 & 3.5.4 & 3.5.5 & 3.5.6; GMW 3097 (2019), Sections 3.5.3 & 3.5.4 & 3.5.5; GMW 3097 (2022), Sections 3.5.3 & 3.5.4 & 3.5.5; VW TL81000 (2018), Section 5.4.5; VW TL81000 (2021), Section 5.4.4; GS 95002-2_2021, Section 6.9; FORD FMC1278-2021 (CI 210); FORD FMC1278-2021(CI 230); FORD FMC1278-2021(CI 231); FORD FMC1278-2021(CI 260); FORD FMC1278-2021(CI 270); FORD FMC1278-2021(CI 250)--
5CS.00054 (2018), Section 5.4--
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SHANGHAI YANFENG JINQIAO AUTOMOTIVE TRIM SYSTEMS CO., LTD. AUTOMOTIVE TRIM & ELECTRONICS TESTING LABORATORY Shanghai, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 11th day of November 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2603.01 Valid to November 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.