Bureau Veritas Consumer Products Services Germany
Thurn-und-Taxis-Straße 18, 90411, Nürnberg, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Bureau Veritas Consumer Products Services Germany?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-12024-06-02Active
- D-PL-12024-06-03Active
- D-PL-12024-06-04Active
- D-PL-12024-06-05Active
- D-PL-12024-06-01Active
- D-PL-12024-06-00Active
Accredited standards
110Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ETSI
ETSI EN 300 127Name not checked yet
ETSI EN 300 127 V1.2.1; ETSI EN 300 220 -1 V3.1.1; ETSI EN 300 220 -2 V3.2.1; ETSI EN 300 220 -3-1 V2.1.1
ETSI EN 300 220-1Name not checked yet
ETSI EN 300 127 V1.2.1; ETSI EN 300 220 -1 V3.1.1; ETSI EN 300 220 -2 V3.2.1; ETSI EN 300 220 -3-1 V2.1.1
ETSI EN 300 220-2Name not checked yet
ETSI EN 300 127 V1.2.1; ETSI EN 300 220 -1 V3.1.1; ETSI EN 300 220 -2 V3.2.1; ETSI EN 300 220 -3-1 V2.1.1
ETSI EN 300 220-3-1Name not checked yet
ETSI EN 300 127 V1.2.1; ETSI EN 300 220 -1 V3.1.1; ETSI EN 300 220 -2 V3.2.1; ETSI EN 300 220 -3-1 V2.1.1
ETSI EN 300 220-3-2Name not checked yet
ETSI EN 300 220 -3-2 V1.1.1 (2017-02); ETSI EN 300 220 -4 V1.1.1 (2017-02); ETSI EN 300 328 V2.2.2 (2019-07); ETSI EN 300 330 V2.1.1 (2017-02); ETSI EN 300 440 V2.2.1 (2018-07); ETSI EN 301 511 V12.5.1 (2017-03); ETSI EN 301 893 V2.1.1 (2017-05)
ETSI EN 300 220-4Name not checked yet
ETSI EN 300 220 -3-2 V1.1.1 (2017-02); ETSI EN 300 220 -4 V1.1.1 (2017-02); ETSI EN 300 328 V2.2.2 (2019-07); ETSI EN 300 330 V2.1.1 (2017-02); ETSI EN 300 440 V2.2.1 (2018-07); ETSI EN 301 511 V12.5.1 (2017-03); ETSI EN 301 893 V2.1.1 (2017-05)
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 220 -3-2 V1.1.1 (2017-02); ETSI EN 300 220 -4 V1.1.1 (2017-02); ETSI EN 300 328 V2.2.2 (2019-07); ETSI EN 300 330 V2.1.1 (2017-02); ETSI EN 300 440 V2.2.1 (2018-07); ETSI EN 301 511 V12.5.1 (2017-03); ETSI EN 301 893 V2.1.1 (2017-05)
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 220 -3-2 V1.1.1 (2017-02); ETSI EN 300 220 -4 V1.1.1 (2017-02); ETSI EN 300 328 V2.2.2 (2019-07); ETSI EN 300 330 V2.1.1 (2017-02); ETSI EN 300 440 V2.2.1 (2018-07); ETSI EN 301 511 V12.5.1 (2017-03); ETSI EN 301 893 V2.1.1 (2017-05)
ETSI EN 300 386Name not checked yet
DIN EN IEC 61326 -3-2:2019-10; VDE 0843-20-3-2:2019-10; EN IEC 61326-3-2:2018; EN 61000-4-16; DIN EN 1434 -4:2023-03; EN 1434-4:2022; ETSI ES 201 468 V1.7.1; ETSI EN 300 386 V2.2.1; ETSI EN 301 489 -1 V2.2.3:2019-11; ETSI EN 301 489 -3 V2.3.2:2023-01
ETSI EN 300 440Name not checked yet
ETSI EN 300 220 -3-2 V1.1.1 (2017-02); ETSI EN 300 220 -4 V1.1.1 (2017-02); ETSI EN 300 328 V2.2.2 (2019-07); ETSI EN 300 330 V2.1.1 (2017-02); ETSI EN 300 440 V2.2.1 (2018-07); ETSI EN 301 511 V12.5.1 (2017-03); ETSI EN 301 893 V2.1.1 (2017-05)
ETSI EN 301 489-1Name not checked yet
DIN EN IEC 61326 -3-2:2019-10; VDE 0843-20-3-2:2019-10; EN IEC 61326-3-2:2018; EN 61000-4-16; DIN EN 1434 -4:2023-03; EN 1434-4:2022; ETSI ES 201 468 V1.7.1; ETSI EN 300 386 V2.2.1; ETSI EN 301 489 -1 V2.2.3:2019-11; ETSI EN 301 489 -3 V2.3.2:2023-01
ETSI EN 301 489-3Name not checked yet
DIN EN IEC 61326 -3-2:2019-10; VDE 0843-20-3-2:2019-10; EN IEC 61326-3-2:2018; EN 61000-4-16; DIN EN 1434 -4:2023-03; EN 1434-4:2022; ETSI ES 201 468 V1.7.1; ETSI EN 300 386 V2.2.1; ETSI EN 301 489 -1 V2.2.3:2019-11; ETSI EN 301 489 -3 V2.3.2:2023-01
ETSI EN 301 489-5Name not checked yet
ETSI EN 301 489-5 V2.2.8; ETSI EN 301 489-17 V3.3.1; ETSI EN 301 489-18 V1.3.1; ETSI EN 301 489-19 V2.2.1
ETSI EN 301 489-17Name not checked yet
ETSI EN 301 489-5 V2.2.8; ETSI EN 301 489-17 V3.3.1; ETSI EN 301 489-18 V1.3.1; ETSI EN 301 489-19 V2.2.1
ETSI EN 301 489-18Name not checked yet
ETSI EN 301 489-5 V2.2.8; ETSI EN 301 489-17 V3.3.1; ETSI EN 301 489-18 V1.3.1; ETSI EN 301 489-19 V2.2.1
ETSI EN 301 489-19Name not checked yet
ETSI EN 301 489-5 V2.2.8; ETSI EN 301 489-17 V3.3.1; ETSI EN 301 489-18 V1.3.1; ETSI EN 301 489-19 V2.2.1
ETSI EN 301 489-24Name not checked yet
ETSI EN 301 489 -24 V1.5.1; ETSI EN 301 489 -50 V2.3.1; ETSI EN 301 489 -52 V1.3.1; ETSI EN 303 446 -1 V1.2.1; ETSI EN 303 446 -2 V1.2.1; CISPR 25:2021
ETSI EN 301 489-50Name not checked yet
ETSI EN 301 489 -24 V1.5.1; ETSI EN 301 489 -50 V2.3.1; ETSI EN 301 489 -52 V1.3.1; ETSI EN 303 446 -1 V1.2.1; ETSI EN 303 446 -2 V1.2.1; CISPR 25:2021
ETSI EN 301 489-52Name not checked yet
ETSI EN 301 489 -24 V1.5.1; ETSI EN 301 489 -50 V2.3.1; ETSI EN 301 489 -52 V1.3.1; ETSI EN 303 446 -1 V1.2.1; ETSI EN 303 446 -2 V1.2.1; CISPR 25:2021
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 220 -3-2 V1.1.1 (2017-02); ETSI EN 300 220 -4 V1.1.1 (2017-02); ETSI EN 300 328 V2.2.2 (2019-07); ETSI EN 300 330 V2.1.1 (2017-02); ETSI EN 300 440 V2.2.1 (2018-07); ETSI EN 301 511 V12.5.1 (2017-03); ETSI EN 301 893 V2.1.1 (2017-05)
ETSI EN 301 893Name not checked yet
ETSI EN 300 220 -3-2 V1.1.1 (2017-02); ETSI EN 300 220 -4 V1.1.1 (2017-02); ETSI EN 300 328 V2.2.2 (2019-07); ETSI EN 300 330 V2.1.1 (2017-02); ETSI EN 300 440 V2.2.1 (2018-07); ETSI EN 301 511 V12.5.1 (2017-03); ETSI EN 301 893 V2.1.1 (2017-05)
ETSI EN 301 908-1Name not checked yet
ETSI EN 301 908 -1 V13.1.1; ETSI EN 301 908 -2 V13.1.1; ETSI EN 301 908 -3 V13.1.1; ETSI EN 301 908 -6 V5.2.1; ETSI EN 301 908 -7 V5.2.1; ETSI EN 301 908 -13 V13.1.1; AN SI C 63 .10 -2013; ANSI C 63.10-2020; IEC 60068 -2-1: 20 07; DIN EN 60068 -2-1:2008 -01; VDE 0468-2-1:2008-01; IEC 60068 -2-2: 20 07
ETSI EN 301 908-2Name not checked yet
ETSI EN 301 908 -1 V13.1.1; ETSI EN 301 908 -2 V13.1.1; ETSI EN 301 908 -3 V13.1.1; ETSI EN 301 908 -6 V5.2.1; ETSI EN 301 908 -7 V5.2.1; ETSI EN 301 908 -13 V13.1.1; AN SI C 63 .10 -2013; ANSI C 63.10-2020; IEC 60068 -2-1: 20 07; DIN EN 60068 -2-1:2008 -01; VDE 0468-2-1:2008-01; IEC 60068 -2-2: 20 07
ETSI EN 301 908-3Name not checked yet
ETSI EN 301 908 -1 V13.1.1; ETSI EN 301 908 -2 V13.1.1; ETSI EN 301 908 -3 V13.1.1; ETSI EN 301 908 -6 V5.2.1; ETSI EN 301 908 -7 V5.2.1; ETSI EN 301 908 -13 V13.1.1; AN SI C 63 .10 -2013; ANSI C 63.10-2020; IEC 60068 -2-1: 20 07; DIN EN 60068 -2-1:2008 -01; VDE 0468-2-1:2008-01; IEC 60068 -2-2: 20 07
ETSI EN 301 908-6Name not checked yet
ETSI EN 301 908 -1 V13.1.1; ETSI EN 301 908 -2 V13.1.1; ETSI EN 301 908 -3 V13.1.1; ETSI EN 301 908 -6 V5.2.1; ETSI EN 301 908 -7 V5.2.1; ETSI EN 301 908 -13 V13.1.1; AN SI C 63 .10 -2013; ANSI C 63.10-2020; IEC 60068 -2-1: 20 07; DIN EN 60068 -2-1:2008 -01; VDE 0468-2-1:2008-01; IEC 60068 -2-2: 20 07
ETSI EN 301 908-7Name not checked yet
ETSI EN 301 908 -1 V13.1.1; ETSI EN 301 908 -2 V13.1.1; ETSI EN 301 908 -3 V13.1.1; ETSI EN 301 908 -6 V5.2.1; ETSI EN 301 908 -7 V5.2.1; ETSI EN 301 908 -13 V13.1.1; AN SI C 63 .10 -2013; ANSI C 63.10-2020; IEC 60068 -2-1: 20 07; DIN EN 60068 -2-1:2008 -01; VDE 0468-2-1:2008-01; IEC 60068 -2-2: 20 07
ETSI EN 301 908-13Name not checked yet
ETSI EN 301 908 -1 V13.1.1; ETSI EN 301 908 -2 V13.1.1; ETSI EN 301 908 -3 V13.1.1; ETSI EN 301 908 -6 V5.2.1; ETSI EN 301 908 -7 V5.2.1; ETSI EN 301 908 -13 V13.1.1; AN SI C 63 .10 -2013; ANSI C 63.10-2020; IEC 60068 -2-1: 20 07; DIN EN 60068 -2-1:2008 -01; VDE 0468-2-1:2008-01; IEC 60068 -2-2: 20 07
ETSI EN 303 446-1Name not checked yet
ETSI EN 301 489 -24 V1.5.1; ETSI EN 301 489 -50 V2.3.1; ETSI EN 301 489 -52 V1.3.1; ETSI EN 303 446 -1 V1.2.1; ETSI EN 303 446 -2 V1.2.1; CISPR 25:2021
ETSI EN 303 446-2Name not checked yet
ETSI EN 301 489 -24 V1.5.1; ETSI EN 301 489 -50 V2.3.1; ETSI EN 301 489 -52 V1.3.1; ETSI EN 303 446 -1 V1.2.1; ETSI EN 303 446 -2 V1.2.1; CISPR 25:2021
ETSI ES 201 468Name not checked yet
DIN EN IEC 61326 -3-2:2019-10; VDE 0843-20-3-2:2019-10; EN IEC 61326-3-2:2018; EN 61000-4-16; DIN EN 1434 -4:2023-03; EN 1434-4:2022; ETSI ES 201 468 V1.7.1; ETSI EN 300 386 V2.2.1; ETSI EN 301 489 -1 V2.2.3:2019-11; ETSI EN 301 489 -3 V2.3.2:2023-01
IEC 61000 series
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000 -3-2:2018 + AMD1:2020 + AMD2:2024; DIN EN IEC 61000 -3-2: 2019-12 (VDE 0838-2:2019-12) (EN IEC 61000 -3-2:2019 + A1:2021); IEC 61000 -3-3:2013 + AMD1:2017 + AMD2:2021 + COR1:2022; DIN EN 61000 -3-3:2023 -02 + Beiblatt 1 :2024-02 (VDE 0838-3:2023-02+ Beiblatt 1 :2024-02) (EN 61000 -3-3:2013 + A1:2019 + A2:2021 + A2:2021/AC:2022); IEC 61000 -3-11:2017
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000 -3-2:2018 + AMD1:2020 + AMD2:2024; DIN EN IEC 61000 -3-2: 2019-12 (VDE 0838-2:2019-12) (EN IEC 61000 -3-2:2019 + A1:2021); IEC 61000 -3-3:2013 + AMD1:2017 + AMD2:2021 + COR1:2022; DIN EN 61000 -3-3:2023 -02 + Beiblatt 1 :2024-02 (VDE 0838-3:2023-02+ Beiblatt 1 :2024-02) (EN 61000 -3-3:2013 + A1:2019 + A2:2021 + A2:2021/AC:2022); IEC 61000 -3-11:2017
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000 -3-2:2018 + AMD1:2020 + AMD2:2024; DIN EN IEC 61000 -3-2: 2019-12 (VDE 0838-2:2019-12) (EN IEC 61000 -3-2:2019 + A1:2021); IEC 61000 -3-3:2013 + AMD1:2017 + AMD2:2021 + COR1:2022; DIN EN 61000 -3-3:2023 -02 + Beiblatt 1 :2024-02 (VDE 0838-3:2023-02+ Beiblatt 1 :2024-02) (EN 61000 -3-3:2013 + A1:2019 + A2:2021 + A2:2021/AC:2022); IEC 61000 -3-11:2017
DIN EN IEC 61000 -3-11:2021-03; VDE 0838-11:2021-03; EN IEC 61000-3-11:2019; IEC 61000 -3-12:2011 + AMD1:2021; DIN EN 61000 -3-12:2012-06; VDE 0838-12:2012-06; EN 61000-3-12:2011; DIN EN 50130 -4:2015-04; VDE 0830-1-4:2015-04; EN 50130-4:2011 + A1:2014; DIN EN 50155:2022-06; VDE 0115-200:2022-06; EN 50155:2021; DIN EN 50083 -2:2016-03; VDE 0855-200:2016-03; EN 50083-2:2012 + A1:2015
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phaseCertificate says EN 61000-3-12. Probably the same standard; not checked against the EN document.
DIN EN IEC 61000 -3-11:2021-03; VDE 0838-11:2021-03; EN IEC 61000-3-11:2019; IEC 61000 -3-12:2011 + AMD1:2021; DIN EN 61000 -3-12:2012-06; VDE 0838-12:2012-06; EN 61000-3-12:2011; DIN EN 50130 -4:2015-04; VDE 0830-1-4:2015-04; EN 50130-4:2011 + A1:2014; DIN EN 50155:2022-06; VDE 0115-200:2022-06; EN 50155:2021; DIN EN 50083 -2:2016-03; VDE 0855-200:2016-03; EN 50083-2:2012 + A1:2015
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-2:2008; DIN EN 61000-4-2:2009-12; VDE 0847-4-20:2009-12; EN 61000-4-2:2009; IEC 61000-4-3:2020; DIN EN IEC 61000-4-3:2021-11; VDE 0847-4-3:2021-11; EN IEC 61000-4-3:2020; IEC 61000-4-4:2012; DIN EN 61000-4-4:2013-04; VDE 0847-4-4:2013-04; EN 61000-4-4:2012; IEC 61000-4-5:2014 + AMD1:2017; DIN EN 61000-4-5:2019-03; VDE 0847-4-5:2019-03; EN 61000-4-5:2014 + A1:2017; IEC 61000-4-6:2023
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
IEC 61000-4-2:2008; DIN EN 61000-4-2:2009-12; VDE 0847-4-20:2009-12; EN 61000-4-2:2009; IEC 61000-4-3:2020; DIN EN IEC 61000-4-3:2021-11; VDE 0847-4-3:2021-11; EN IEC 61000-4-3:2020; IEC 61000-4-4:2012; DIN EN 61000-4-4:2013-04; VDE 0847-4-4:2013-04; EN 61000-4-4:2012; IEC 61000-4-5:2014 + AMD1:2017; DIN EN 61000-4-5:2019-03; VDE 0847-4-5:2019-03; EN 61000-4-5:2014 + A1:2017; IEC 61000-4-6:2023
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-2:2008; DIN EN 61000-4-2:2009-12; VDE 0847-4-20:2009-12; EN 61000-4-2:2009; IEC 61000-4-3:2020; DIN EN IEC 61000-4-3:2021-11; VDE 0847-4-3:2021-11; EN IEC 61000-4-3:2020; IEC 61000-4-4:2012; DIN EN 61000-4-4:2013-04; VDE 0847-4-4:2013-04; EN 61000-4-4:2012; IEC 61000-4-5:2014 + AMD1:2017; DIN EN 61000-4-5:2019-03; VDE 0847-4-5:2019-03; EN 61000-4-5:2014 + A1:2017; IEC 61000-4-6:2023
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-2:2008; DIN EN 61000-4-2:2009-12; VDE 0847-4-20:2009-12; EN 61000-4-2:2009; IEC 61000-4-3:2020; DIN EN IEC 61000-4-3:2021-11; VDE 0847-4-3:2021-11; EN IEC 61000-4-3:2020; IEC 61000-4-4:2012; DIN EN 61000-4-4:2013-04; VDE 0847-4-4:2013-04; EN 61000-4-4:2012; IEC 61000-4-5:2014 + AMD1:2017; DIN EN 61000-4-5:2019-03; VDE 0847-4-5:2019-03; EN 61000-4-5:2014 + A1:2017; IEC 61000-4-6:2023
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-2:2008; DIN EN 61000-4-2:2009-12; VDE 0847-4-20:2009-12; EN 61000-4-2:2009; IEC 61000-4-3:2020; DIN EN IEC 61000-4-3:2021-11; VDE 0847-4-3:2021-11; EN IEC 61000-4-3:2020; IEC 61000-4-4:2012; DIN EN 61000-4-4:2013-04; VDE 0847-4-4:2013-04; EN 61000-4-4:2012; IEC 61000-4-5:2014 + AMD1:2017; DIN EN 61000-4-5:2019-03; VDE 0847-4-5:2019-03; EN 61000-4-5:2014 + A1:2017; IEC 61000-4-6:2023
DIN EN 61000-4-6:2014-08; VDE 0847-4-6:2014-08; EN 61000-4-6:2014; IEC 61000-4-6:2013; IEC 61000-4-8:2009; DIN EN 61000-4-8:2010-11; VDE 0847-4-8:2010-11; EN 61000-4-8:2010; IEC 61000-4-8:2009; IEC 61000-4-9:2016; DIN EN 61000-4-9:2017-05; VDE 0847-4-9:2017-05; EN 61000-4-9:2016; IEC 61000-4-9:2016; IEC 61000-4-10:2016; DIN EN 61000-4-10:2018-01; VDE 0847-4-10:2018-01; EN 61000-4-10:2017; IEC 61000-4-10:2016
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
DIN EN 61000-4-6:2014-08; VDE 0847-4-6:2014-08; EN 61000-4-6:2014; IEC 61000-4-6:2013; IEC 61000-4-8:2009; DIN EN 61000-4-8:2010-11; VDE 0847-4-8:2010-11; EN 61000-4-8:2010; IEC 61000-4-8:2009; IEC 61000-4-9:2016; DIN EN 61000-4-9:2017-05; VDE 0847-4-9:2017-05; EN 61000-4-9:2016; IEC 61000-4-9:2016; IEC 61000-4-10:2016; DIN EN 61000-4-10:2018-01; VDE 0847-4-10:2018-01; EN 61000-4-10:2017; IEC 61000-4-10:2016
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
DIN EN 61000-4-6:2014-08; VDE 0847-4-6:2014-08; EN 61000-4-6:2014; IEC 61000-4-6:2013; IEC 61000-4-8:2009; DIN EN 61000-4-8:2010-11; VDE 0847-4-8:2010-11; EN 61000-4-8:2010; IEC 61000-4-8:2009; IEC 61000-4-9:2016; DIN EN 61000-4-9:2017-05; VDE 0847-4-9:2017-05; EN 61000-4-9:2016; IEC 61000-4-9:2016; IEC 61000-4-10:2016; DIN EN 61000-4-10:2018-01; VDE 0847-4-10:2018-01; EN 61000-4-10:2017; IEC 61000-4-10:2016
IEC 61000-4-10Name not checked yet
DIN EN 61000-4-6:2014-08; VDE 0847-4-6:2014-08; EN 61000-4-6:2014; IEC 61000-4-6:2013; IEC 61000-4-8:2009; DIN EN 61000-4-8:2010-11; VDE 0847-4-8:2010-11; EN 61000-4-8:2010; IEC 61000-4-8:2009; IEC 61000-4-9:2016; DIN EN 61000-4-9:2017-05; VDE 0847-4-9:2017-05; EN 61000-4-9:2016; IEC 61000-4-9:2016; IEC 61000-4-10:2016; DIN EN 61000-4-10:2018-01; VDE 0847-4-10:2018-01; EN 61000-4-10:2017; IEC 61000-4-10:2016
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000 -4-11:2020/COR2:2022; DIN EN IEC 61000 -4-11: 2021-10 (VDE 0847-4-11:2021-10) (EN IEC 61000-4-11:2020 + AC:2020); IEC 61000 -4-12:2017; DIN EN 61000 -4-12:2019 -03 (VDE 0847-4-12:2019-03) (EN 61000-4-12:2017); IEC 61000 -4-13:2002 + AMD1:2009 + AMD2:2015
IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
IEC 61000 -4-11:2020/COR2:2022; DIN EN IEC 61000 -4-11: 2021-10 (VDE 0847-4-11:2021-10) (EN IEC 61000-4-11:2020 + AC:2020); IEC 61000 -4-12:2017; DIN EN 61000 -4-12:2019 -03 (VDE 0847-4-12:2019-03) (EN 61000-4-12:2017); IEC 61000 -4-13:2002 + AMD1:2009 + AMD2:2015
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000 -4-11:2020/COR2:2022; DIN EN IEC 61000 -4-11: 2021-10 (VDE 0847-4-11:2021-10) (EN IEC 61000-4-11:2020 + AC:2020); IEC 61000 -4-12:2017; DIN EN 61000 -4-12:2019 -03 (VDE 0847-4-12:2019-03) (EN 61000-4-12:2017); IEC 61000 -4-13:2002 + AMD1:2009 + AMD2:2015
DIN EN 61000-4-13:2016-10; VDE 0847-4-13:2016-10; EN 61000-4-13:2002 + A1:2009 + A2:2016; IEC 61000-4-13:2002 + A1:2009 + A2:2015; IEC 61000-4-18:2019 / COR1:2019; DIN EN IEC 61000-4-18:2020-09; VDE 0847-4-18:2020-09; EN IEC 61000-4-18:2019 + AC:2019; IEC 61000-4-18:2019 + COR1:2019; IEC 61000-4-27:2000 + AMD1:2009; DIN EN 61000-4-27:2009-12; VDE 0847-4-27:2009-12; EN 61000-4-27:2000 + A1:2009; IEC 61000-4-27:2000 + A1:2009; IEC 61000-4-29:2000
IEC 61000-4-16Name not checked yet
DIN EN IEC 61326-2-2; VDE 0843-20-2-2; EN IEC 61326-2-2; IEC 61326-2-2; DIN EN IEC 61326-2-3; VDE 0843-20-2-3; EN IEC 61326-2-3; IEC 61326-2-3; DIN EN IEC 61326-2-4; VDE 0843-20-2-4; EN IEC 61326-2-4; IEC 61326-2-4; DIN EN IEC 61326-2-5; VDE 0843-20-2-5; EN IEC 61326-2-5; IEC 61326-2-5; DIN EN 61326-3-1; VDE 0843-20-3-1; EN 61326-3-1; IEC 61326-3-1; EN 61000-4-16
DIN EN IEC 61326 -3-2:2019-10; VDE 0843-20-3-2:2019-10; EN IEC 61326-3-2:2018; EN 61000-4-16; DIN EN 1434 -4:2023-03; EN 1434-4:2022; ETSI ES 201 468 V1.7.1; ETSI EN 300 386 V2.2.1; ETSI EN 301 489 -1 V2.2.3:2019-11; ETSI EN 301 489 -3 V2.3.2:2023-01
IEC 61000-4-18Name not checked yet
DIN EN 61000-4-13:2016-10; VDE 0847-4-13:2016-10; EN 61000-4-13:2002 + A1:2009 + A2:2016; IEC 61000-4-13:2002 + A1:2009 + A2:2015; IEC 61000-4-18:2019 / COR1:2019; DIN EN IEC 61000-4-18:2020-09; VDE 0847-4-18:2020-09; EN IEC 61000-4-18:2019 + AC:2019; IEC 61000-4-18:2019 + COR1:2019; IEC 61000-4-27:2000 + AMD1:2009; DIN EN 61000-4-27:2009-12; VDE 0847-4-27:2009-12; EN 61000-4-27:2000 + A1:2009; IEC 61000-4-27:2000 + A1:2009; IEC 61000-4-29:2000
IEC 61000-4-27Name not checked yet
DIN EN 61000-4-13:2016-10; VDE 0847-4-13:2016-10; EN 61000-4-13:2002 + A1:2009 + A2:2016; IEC 61000-4-13:2002 + A1:2009 + A2:2015; IEC 61000-4-18:2019 / COR1:2019; DIN EN IEC 61000-4-18:2020-09; VDE 0847-4-18:2020-09; EN IEC 61000-4-18:2019 + AC:2019; IEC 61000-4-18:2019 + COR1:2019; IEC 61000-4-27:2000 + AMD1:2009; DIN EN 61000-4-27:2009-12; VDE 0847-4-27:2009-12; EN 61000-4-27:2000 + A1:2009; IEC 61000-4-27:2000 + A1:2009; IEC 61000-4-29:2000
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
DIN EN 61000-4-13:2016-10; VDE 0847-4-13:2016-10; EN 61000-4-13:2002 + A1:2009 + A2:2016; IEC 61000-4-13:2002 + A1:2009 + A2:2015; IEC 61000-4-18:2019 / COR1:2019; DIN EN IEC 61000-4-18:2020-09; VDE 0847-4-18:2020-09; EN IEC 61000-4-18:2019 + AC:2019; IEC 61000-4-18:2019 + COR1:2019; IEC 61000-4-27:2000 + AMD1:2009; DIN EN 61000-4-27:2009-12; VDE 0847-4-27:2009-12; EN 61000-4-27:2000 + A1:2009; IEC 61000-4-27:2000 + A1:2009; IEC 61000-4-29:2000
DIN EN 61000 -4-29 :2001 -10; VDE 0847-4-29:2001-10; EN 61000-4-29:2000; IEC 61000-4-29:2000; IEC 61000 -4-34:2005 + A1:2009 + Cor.:2009; DIN EN 61000 -4-34:2010 -04; VDE 0847-4-34:2010-04; EN 61000-4-34:2007 + A1:2009; IEC 61000-4-34:2005 + A1:2009 + Cor.:2009; IEC 61000 -4-39:2017; DIN EN 61000 -4-39:2019 -04; VDE 0847-4-39:2019-04; EN 61000-4-39:2017; IEC 61000-4-39:2017
IEC 61000-4-34Name not checked yet
DIN EN 61000 -4-29 :2001 -10; VDE 0847-4-29:2001-10; EN 61000-4-29:2000; IEC 61000-4-29:2000; IEC 61000 -4-34:2005 + A1:2009 + Cor.:2009; DIN EN 61000 -4-34:2010 -04; VDE 0847-4-34:2010-04; EN 61000-4-34:2007 + A1:2009; IEC 61000-4-34:2005 + A1:2009 + Cor.:2009; IEC 61000 -4-39:2017; DIN EN 61000 -4-39:2019 -04; VDE 0847-4-39:2019-04; EN 61000-4-39:2017; IEC 61000-4-39:2017
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
DIN EN 61000 -4-29 :2001 -10; VDE 0847-4-29:2001-10; EN 61000-4-29:2000; IEC 61000-4-29:2000; IEC 61000 -4-34:2005 + A1:2009 + Cor.:2009; DIN EN 61000 -4-34:2010 -04; VDE 0847-4-34:2010-04; EN 61000-4-34:2007 + A1:2009; IEC 61000-4-34:2005 + A1:2009 + Cor.:2009; IEC 61000 -4-39:2017; DIN EN 61000 -4-39:2019 -04; VDE 0847-4-39:2019-04; EN 61000-4-39:2017; IEC 61000-4-39:2017
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
CISPR 16-2-1:2014 + AMD1:2017 + COR1:2020; DIN EN 55016-2-1:2019-11; VDE 0877-16-2-1:2019-11; EN 55016-2-1:2014 + A1:2017; CISPR 16-2-3:2016 + AMD1:2019 + AMD2:2023; DIN EN 55016-2-3:2020-11; VDE 0877-16-2-3:2020-11; EN 55016-2-3:2017 + A1:2019; IEC 61000-6-1:2016; DIN EN IEC 61000-6-1:2019-11; VDE 0839-6-1:2019-11; EN IEC 61000-6-1:2019
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-2:2016; DIN EN IEC 61000-6-2:2019-11; VDE 0839-6-2:2019-11; EN IEC 61000-6-2:2019; IEC 61000-6-3:2020; DIN EN IEC 61000-6-3:2022-06; VDE 0839-6-3:2022-06; EN IEC 61000-6-3:2021; IEC 61000-6-4:2018; DIN EN IEC 61000-6-4:2020-09; VDE 0839-6-4:2020-09; EN IEC 61000-6-4:2019; IEC 61000-6-5:2015/COR1:2017; DIN EN 61000-6-5:2016-07; Berichtigung 1:2019-09; VDE 0839-6-5:2016-07; Berichtigung 1:2019-09; EN 61000-6-5:2015/AC:2018-01; IEC 61000-6-8:2020
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
IEC 61000-6-2:2016; DIN EN IEC 61000-6-2:2019-11; VDE 0839-6-2:2019-11; EN IEC 61000-6-2:2019; IEC 61000-6-3:2020; DIN EN IEC 61000-6-3:2022-06; VDE 0839-6-3:2022-06; EN IEC 61000-6-3:2021; IEC 61000-6-4:2018; DIN EN IEC 61000-6-4:2020-09; VDE 0839-6-4:2020-09; EN IEC 61000-6-4:2019; IEC 61000-6-5:2015/COR1:2017; DIN EN 61000-6-5:2016-07; Berichtigung 1:2019-09; VDE 0839-6-5:2016-07; Berichtigung 1:2019-09; EN 61000-6-5:2015/AC:2018-01; IEC 61000-6-8:2020
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 61000-6-2:2016; DIN EN IEC 61000-6-2:2019-11; VDE 0839-6-2:2019-11; EN IEC 61000-6-2:2019; IEC 61000-6-3:2020; DIN EN IEC 61000-6-3:2022-06; VDE 0839-6-3:2022-06; EN IEC 61000-6-3:2021; IEC 61000-6-4:2018; DIN EN IEC 61000-6-4:2020-09; VDE 0839-6-4:2020-09; EN IEC 61000-6-4:2019; IEC 61000-6-5:2015/COR1:2017; DIN EN 61000-6-5:2016-07; Berichtigung 1:2019-09; VDE 0839-6-5:2016-07; Berichtigung 1:2019-09; EN 61000-6-5:2015/AC:2018-01; IEC 61000-6-8:2020
IEC 61000-6-5Name not checked yet
IEC 61000-6-2:2016; DIN EN IEC 61000-6-2:2019-11; VDE 0839-6-2:2019-11; EN IEC 61000-6-2:2019; IEC 61000-6-3:2020; DIN EN IEC 61000-6-3:2022-06; VDE 0839-6-3:2022-06; EN IEC 61000-6-3:2021; IEC 61000-6-4:2018; DIN EN IEC 61000-6-4:2020-09; VDE 0839-6-4:2020-09; EN IEC 61000-6-4:2019; IEC 61000-6-5:2015/COR1:2017; DIN EN 61000-6-5:2016-07; Berichtigung 1:2019-09; VDE 0839-6-5:2016-07; Berichtigung 1:2019-09; EN 61000-6-5:2015/AC:2018-01; IEC 61000-6-8:2020
IEC 61000-6-8Name not checked yet
IEC 61000-6-2:2016; DIN EN IEC 61000-6-2:2019-11; VDE 0839-6-2:2019-11; EN IEC 61000-6-2:2019; IEC 61000-6-3:2020; DIN EN IEC 61000-6-3:2022-06; VDE 0839-6-3:2022-06; EN IEC 61000-6-3:2021; IEC 61000-6-4:2018; DIN EN IEC 61000-6-4:2020-09; VDE 0839-6-4:2020-09; EN IEC 61000-6-4:2019; IEC 61000-6-5:2015/COR1:2017; DIN EN 61000-6-5:2016-07; Berichtigung 1:2019-09; VDE 0839-6-5:2016-07; Berichtigung 1:2019-09; EN 61000-6-5:2015/AC:2018-01; IEC 61000-6-8:2020
DIN EN IEC 61000-6-8; VDE 0839-6-8; EN IEC 61000-6-8; IEC 61000-6-8; DIN EN 50121-3-2; VDE 0115-121-3-2; EN 50121-3-2; A1; DIN EN 50121-4; A1; VDE 0115-121-4; A1; EN 50121-4; A1; CISPR 11; DIN EN 55011; VDE 0875-11; EN 55011; A1; CISPR 12; AMD1; DIN EN 55012; VDE 0879-1; EN 55012; IEC/CISPR 12; A1
CISPR
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementCertificate says EN 55011. Probably the same standard; not checked against the EN document.
DIN EN IEC 61000-6-8; VDE 0839-6-8; EN IEC 61000-6-8; IEC 61000-6-8; DIN EN 50121-3-2; VDE 0115-121-3-2; EN 50121-3-2; A1; DIN EN 50121-4; A1; VDE 0115-121-4; A1; EN 50121-4; A1; CISPR 11; DIN EN 55011; VDE 0875-11; EN 55011; A1; CISPR 12; AMD1; DIN EN 55012; VDE 0879-1; EN 55012; IEC/CISPR 12; A1
CISPR 12Vehicles, boats and devices with internal combustion engines or traction batteries - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receiversCertificate says EN 55012. Probably the same standard; not checked against the EN document.
DIN EN IEC 61000-6-8; VDE 0839-6-8; EN IEC 61000-6-8; IEC 61000-6-8; DIN EN 50121-3-2; VDE 0115-121-3-2; EN 50121-3-2; A1; DIN EN 50121-4; A1; VDE 0115-121-4; A1; EN 50121-4; A1; CISPR 11; DIN EN 55011; VDE 0875-11; EN 55011; A1; CISPR 12; AMD1; DIN EN 55012; VDE 0879-1; EN 55012; IEC/CISPR 12; A1
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurementCertificate says EN 55013. Probably the same standard; not checked against the EN document.
CISPR 13:2009 + AMD1:2015; DIN EN 55013:2013 -11; CISPR 14 -1:2020; DIN EN IEC 55014 -1:2022 -12; CISPR 14 -2:2020; DIN EN IEC 55014 -2:2022 -10; CISPR 22:2008 + AMD1:2010; DIN EN 55022:2011 -12; CISPR 24:2010 + AMD1:2015; DIN EN 55024:2016 -05
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionCertificate says IEC 55014-1. Probably the same standard; not checked against the EN document.
CISPR 13:2009 + AMD1:2015; DIN EN 55013:2013 -11; CISPR 14 -1:2020; DIN EN IEC 55014 -1:2022 -12; CISPR 14 -2:2020; DIN EN IEC 55014 -2:2022 -10; CISPR 22:2008 + AMD1:2010; DIN EN 55022:2011 -12; CISPR 24:2010 + AMD1:2015; DIN EN 55024:2016 -05
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standardCertificate says IEC 55014-2. Probably the same standard; not checked against the EN document.
CISPR 13:2009 + AMD1:2015; DIN EN 55013:2013 -11; CISPR 14 -1:2020; DIN EN IEC 55014 -1:2022 -12; CISPR 14 -2:2020; DIN EN IEC 55014 -2:2022 -10; CISPR 22:2008 + AMD1:2010; DIN EN 55022:2011 -12; CISPR 24:2010 + AMD1:2015; DIN EN 55024:2016 -05
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurementsCertificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.
CISPR 16-2-1:2014 + AMD1:2017 + COR1:2020; DIN EN 55016-2-1:2019-11; VDE 0877-16-2-1:2019-11; EN 55016-2-1:2014 + A1:2017; CISPR 16-2-3:2016 + AMD1:2019 + AMD2:2023; DIN EN 55016-2-3:2020-11; VDE 0877-16-2-3:2020-11; EN 55016-2-3:2017 + A1:2019; IEC 61000-6-1:2016; DIN EN IEC 61000-6-1:2019-11; VDE 0839-6-1:2019-11; EN IEC 61000-6-1:2019
CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurementsCertificate says EN 55016-2-3. Probably the same standard; not checked against the EN document.
CISPR 16-2-1:2014 + AMD1:2017 + COR1:2020; DIN EN 55016-2-1:2019-11; VDE 0877-16-2-1:2019-11; EN 55016-2-1:2014 + A1:2017; CISPR 16-2-3:2016 + AMD1:2019 + AMD2:2023; DIN EN 55016-2-3:2020-11; VDE 0877-16-2-3:2020-11; EN 55016-2-3:2017 + A1:2019; IEC 61000-6-1:2016; DIN EN IEC 61000-6-1:2019-11; VDE 0839-6-1:2019-11; EN IEC 61000-6-1:2019
CISPR 20Name not checked yetCertificate says EN 55020. Probably the same standard; not checked against the EN document.
DIN EN 55020/A12:2017-01; VDE 0872-20/A2:2017-01; CISPR 20:2006 +AMD1:2013; CISPR 32:2015 + AMD 1:2019; DIN EN 55032:2022-08; VDE 0878-32:2022-08; CISPR 35:2016; DIN EN 55035:2018-04; VDE 0878-35:2018-04; DIN EN IEC 61326-1:2022-11; VDE 0843-20-1:2022-11; DIN EN IEC 61326-2-2: 2022-11; VDE 0843-20-2-2:2022-11
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurementCertificate says EN 55022. Probably the same standard; not checked against the EN document.
CISPR 13:2009 + AMD1:2015; DIN EN 55013:2013 -11; CISPR 14 -1:2020; DIN EN IEC 55014 -1:2022 -12; CISPR 14 -2:2020; DIN EN IEC 55014 -2:2022 -10; CISPR 22:2008 + AMD1:2010; DIN EN 55022:2011 -12; CISPR 24:2010 + AMD1:2015; DIN EN 55024:2016 -05
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurementCertificate says EN 55024. Probably the same standard; not checked against the EN document.
CISPR 13:2009 + AMD1:2015; DIN EN 55013:2013 -11; CISPR 14 -1:2020; DIN EN IEC 55014 -1:2022 -12; CISPR 14 -2:2020; DIN EN IEC 55014 -2:2022 -10; CISPR 22:2008 + AMD1:2010; DIN EN 55022:2011 -12; CISPR 24:2010 + AMD1:2015; DIN EN 55024:2016 -05
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receiversCertificate says IEC 55025. Probably the same standard; not checked against the EN document.
DIN EN IEC 55025:2023 -11; VDE 0879-2:2023-11; EN IEC 55025:2022; CISPR 25:2021; ISO 10605:2008 + Cor.1:2010; DIN EN 50498:2011 -04; VDE 0879-498:2011-04; EN 50498:2010; ISO 11452 -1:2015; ISO 11452 -2:2019; ISO 11452 -4:2020; ISO 11452-4:2011; ISO 11452 -5:2002; ISO 11452 -8:2015; ISO 11452 -9:2021
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsCertificate says EN 55032. Probably the same standard; not checked against the EN document.
DIN EN 55020/A12:2017-01; VDE 0872-20/A2:2017-01; CISPR 20:2006 +AMD1:2013; CISPR 32:2015 + AMD 1:2019; DIN EN 55032:2022-08; VDE 0878-32:2022-08; CISPR 35:2016; DIN EN 55035:2018-04; VDE 0878-35:2018-04; DIN EN IEC 61326-1:2022-11; VDE 0843-20-1:2022-11; DIN EN IEC 61326-2-2: 2022-11; VDE 0843-20-2-2:2022-11
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsCertificate says EN 55035. Probably the same standard; not checked against the EN document.
DIN EN 55020/A12:2017-01; VDE 0872-20/A2:2017-01; CISPR 20:2006 +AMD1:2013; CISPR 32:2015 + AMD 1:2019; DIN EN 55032:2022-08; VDE 0878-32:2022-08; CISPR 35:2016; DIN EN 55035:2018-04; VDE 0878-35:2018-04; DIN EN IEC 61326-1:2022-11; VDE 0843-20-1:2022-11; DIN EN IEC 61326-2-2: 2022-11; VDE 0843-20-2-2:2022-11
IEC 60068 series
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
ETSI EN 301 908 -1 V13.1.1; ETSI EN 301 908 -2 V13.1.1; ETSI EN 301 908 -3 V13.1.1; ETSI EN 301 908 -6 V5.2.1; ETSI EN 301 908 -7 V5.2.1; ETSI EN 301 908 -13 V13.1.1; AN SI C 63 .10 -2013; ANSI C 63.10-2020; IEC 60068 -2-1: 20 07; DIN EN 60068 -2-1:2008 -01; VDE 0468-2-1:2008-01; IEC 60068 -2-2: 20 07
DIN EN 60512-2-1:2003-01; EN 60512-2-1:2002; IEC 60512-2-1:2002; DIN EN 60512-2-2:2004-01; EN 60512-2-2:2003; IEC 60512-2-2:2003; DIN EN 60512-3-1:2003-01; EN 60512-3-1:2002; IEC 60512-3-1:2002; DIN EN 60512-4-1:2003-01; EN 60512-4-1:2002; IEC 60512-4-1:2003; DIN EN 60068-2-1; IEC 60068-2-1; DIN EN 60068-2-2; IEC 60068-2-2; DIN EN 60068-2-14 (Nb); IEC 60068-2-14 (Nb); DIN EN 60068-2-30; IEC 60068-2-30; DIN EN 60068-2-38; IEC 60068-2-38; DIN EN 60068-2-78
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
ETSI EN 301 908 -1 V13.1.1; ETSI EN 301 908 -2 V13.1.1; ETSI EN 301 908 -3 V13.1.1; ETSI EN 301 908 -6 V5.2.1; ETSI EN 301 908 -7 V5.2.1; ETSI EN 301 908 -13 V13.1.1; AN SI C 63 .10 -2013; ANSI C 63.10-2020; IEC 60068 -2-1: 20 07; DIN EN 60068 -2-1:2008 -01; VDE 0468-2-1:2008-01; IEC 60068 -2-2: 20 07
DIN EN 60068 -2-2:2008 -05; VDE 0468-2-2:2008-05; IEC 60068-2-2:2007; IEC 60068 -2-6: 2007 -12; DIN EN 60068 -2-6:2008 -10; VDE 0468-2-6:2008-10; IEC 60068-2-14: 20 09; DIN EN 60068 -2-14: 2010-04; VDE 0468-2-14:2010-04; EN IEC 60068-2-14:2009; IEC 60068 -2-27: 2008 -02; DIN EN 60068 -2-27:2010 -02; VDE 0468-2-27: 2010-02; IEC 60068 -2-30:20 05; DIN EN 60068 -2-30:2006 -06; IEC 60068 -2-31:200 8; DIN EN 60068 -2-31:2009 -04; VDE 0468-2-31:2009-04; IEC 60068 -2-38:2021
DIN EN 60512-2-1:2003-01; EN 60512-2-1:2002; IEC 60512-2-1:2002; DIN EN 60512-2-2:2004-01; EN 60512-2-2:2003; IEC 60512-2-2:2003; DIN EN 60512-3-1:2003-01; EN 60512-3-1:2002; IEC 60512-3-1:2002; DIN EN 60512-4-1:2003-01; EN 60512-4-1:2002; IEC 60512-4-1:2003; DIN EN 60068-2-1; IEC 60068-2-1; DIN EN 60068-2-2; IEC 60068-2-2; DIN EN 60068-2-14 (Nb); IEC 60068-2-14 (Nb); DIN EN 60068-2-30; IEC 60068-2-30; DIN EN 60068-2-38; IEC 60068-2-38; DIN EN 60068-2-78
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
DIN EN 60068 -2-2:2008 -05; VDE 0468-2-2:2008-05; IEC 60068-2-2:2007; IEC 60068 -2-6: 2007 -12; DIN EN 60068 -2-6:2008 -10; VDE 0468-2-6:2008-10; IEC 60068-2-14: 20 09; DIN EN 60068 -2-14: 2010-04; VDE 0468-2-14:2010-04; EN IEC 60068-2-14:2009; IEC 60068 -2-27: 2008 -02; DIN EN 60068 -2-27:2010 -02; VDE 0468-2-27: 2010-02; IEC 60068 -2-30:20 05; DIN EN 60068 -2-30:2006 -06; IEC 60068 -2-31:200 8; DIN EN 60068 -2-31:2009 -04; VDE 0468-2-31:2009-04; IEC 60068 -2-38:2021
IEC 60068-2-78; DIN EN 60068-2-14 Na, Nb; IEC 60068-2-14 Na, Nb; DIN EN 60068-2-6; IEC 60068-2-6; DIN EN 60068-2-64; IEC 60068-2-64; DIN EN 60068-2-27; IEC 60068-2-27; DIN EN 60068-2-31; DIN EN 60512-2-1; DIN EN 60512-2-2; DIN EN 60512-3-1
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
DIN EN 60068 -2-2:2008 -05; VDE 0468-2-2:2008-05; IEC 60068-2-2:2007; IEC 60068 -2-6: 2007 -12; DIN EN 60068 -2-6:2008 -10; VDE 0468-2-6:2008-10; IEC 60068-2-14: 20 09; DIN EN 60068 -2-14: 2010-04; VDE 0468-2-14:2010-04; EN IEC 60068-2-14:2009; IEC 60068 -2-27: 2008 -02; DIN EN 60068 -2-27:2010 -02; VDE 0468-2-27: 2010-02; IEC 60068 -2-30:20 05; DIN EN 60068 -2-30:2006 -06; IEC 60068 -2-31:200 8; DIN EN 60068 -2-31:2009 -04; VDE 0468-2-31:2009-04; IEC 60068 -2-38:2021
DIN EN 60512-2-1:2003-01; EN 60512-2-1:2002; IEC 60512-2-1:2002; DIN EN 60512-2-2:2004-01; EN 60512-2-2:2003; IEC 60512-2-2:2003; DIN EN 60512-3-1:2003-01; EN 60512-3-1:2002; IEC 60512-3-1:2002; DIN EN 60512-4-1:2003-01; EN 60512-4-1:2002; IEC 60512-4-1:2003; DIN EN 60068-2-1; IEC 60068-2-1; DIN EN 60068-2-2; IEC 60068-2-2; DIN EN 60068-2-14 (Nb); IEC 60068-2-14 (Nb); DIN EN 60068-2-30; IEC 60068-2-30; DIN EN 60068-2-38; IEC 60068-2-38; DIN EN 60068-2-78
IEC 60068-2-78; DIN EN 60068-2-14 Na, Nb; IEC 60068-2-14 Na, Nb; DIN EN 60068-2-6; IEC 60068-2-6; DIN EN 60068-2-64; IEC 60068-2-64; DIN EN 60068-2-27; IEC 60068-2-27; DIN EN 60068-2-31; DIN EN 60512-2-1; DIN EN 60512-2-2; DIN EN 60512-3-1
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
DIN EN 60068 -2-2:2008 -05; VDE 0468-2-2:2008-05; IEC 60068-2-2:2007; IEC 60068 -2-6: 2007 -12; DIN EN 60068 -2-6:2008 -10; VDE 0468-2-6:2008-10; IEC 60068-2-14: 20 09; DIN EN 60068 -2-14: 2010-04; VDE 0468-2-14:2010-04; EN IEC 60068-2-14:2009; IEC 60068 -2-27: 2008 -02; DIN EN 60068 -2-27:2010 -02; VDE 0468-2-27: 2010-02; IEC 60068 -2-30:20 05; DIN EN 60068 -2-30:2006 -06; IEC 60068 -2-31:200 8; DIN EN 60068 -2-31:2009 -04; VDE 0468-2-31:2009-04; IEC 60068 -2-38:2021
IEC 60068-2-78; DIN EN 60068-2-14 Na, Nb; IEC 60068-2-14 Na, Nb; DIN EN 60068-2-6; IEC 60068-2-6; DIN EN 60068-2-64; IEC 60068-2-64; DIN EN 60068-2-27; IEC 60068-2-27; DIN EN 60068-2-31; DIN EN 60512-2-1; DIN EN 60512-2-2; DIN EN 60512-3-1
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
DIN EN 60068 -2-2:2008 -05; VDE 0468-2-2:2008-05; IEC 60068-2-2:2007; IEC 60068 -2-6: 2007 -12; DIN EN 60068 -2-6:2008 -10; VDE 0468-2-6:2008-10; IEC 60068-2-14: 20 09; DIN EN 60068 -2-14: 2010-04; VDE 0468-2-14:2010-04; EN IEC 60068-2-14:2009; IEC 60068 -2-27: 2008 -02; DIN EN 60068 -2-27:2010 -02; VDE 0468-2-27: 2010-02; IEC 60068 -2-30:20 05; DIN EN 60068 -2-30:2006 -06; IEC 60068 -2-31:200 8; DIN EN 60068 -2-31:2009 -04; VDE 0468-2-31:2009-04; IEC 60068 -2-38:2021
DIN EN 60512-2-1:2003-01; EN 60512-2-1:2002; IEC 60512-2-1:2002; DIN EN 60512-2-2:2004-01; EN 60512-2-2:2003; IEC 60512-2-2:2003; DIN EN 60512-3-1:2003-01; EN 60512-3-1:2002; IEC 60512-3-1:2002; DIN EN 60512-4-1:2003-01; EN 60512-4-1:2002; IEC 60512-4-1:2003; DIN EN 60068-2-1; IEC 60068-2-1; DIN EN 60068-2-2; IEC 60068-2-2; DIN EN 60068-2-14 (Nb); IEC 60068-2-14 (Nb); DIN EN 60068-2-30; IEC 60068-2-30; DIN EN 60068-2-38; IEC 60068-2-38; DIN EN 60068-2-78
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
DIN EN 60068 -2-2:2008 -05; VDE 0468-2-2:2008-05; IEC 60068-2-2:2007; IEC 60068 -2-6: 2007 -12; DIN EN 60068 -2-6:2008 -10; VDE 0468-2-6:2008-10; IEC 60068-2-14: 20 09; DIN EN 60068 -2-14: 2010-04; VDE 0468-2-14:2010-04; EN IEC 60068-2-14:2009; IEC 60068 -2-27: 2008 -02; DIN EN 60068 -2-27:2010 -02; VDE 0468-2-27: 2010-02; IEC 60068 -2-30:20 05; DIN EN 60068 -2-30:2006 -06; IEC 60068 -2-31:200 8; DIN EN 60068 -2-31:2009 -04; VDE 0468-2-31:2009-04; IEC 60068 -2-38:2021
IEC 60068-2-78; DIN EN 60068-2-14 Na, Nb; IEC 60068-2-14 Na, Nb; DIN EN 60068-2-6; IEC 60068-2-6; DIN EN 60068-2-64; IEC 60068-2-64; DIN EN 60068-2-27; IEC 60068-2-27; DIN EN 60068-2-31; DIN EN 60512-2-1; DIN EN 60512-2-2; DIN EN 60512-3-1
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
DIN EN 60068 -2-2:2008 -05; VDE 0468-2-2:2008-05; IEC 60068-2-2:2007; IEC 60068 -2-6: 2007 -12; DIN EN 60068 -2-6:2008 -10; VDE 0468-2-6:2008-10; IEC 60068-2-14: 20 09; DIN EN 60068 -2-14: 2010-04; VDE 0468-2-14:2010-04; EN IEC 60068-2-14:2009; IEC 60068 -2-27: 2008 -02; DIN EN 60068 -2-27:2010 -02; VDE 0468-2-27: 2010-02; IEC 60068 -2-30:20 05; DIN EN 60068 -2-30:2006 -06; IEC 60068 -2-31:200 8; DIN EN 60068 -2-31:2009 -04; VDE 0468-2-31:2009-04; IEC 60068 -2-38:2021
DIN EN 60512-2-1:2003-01; EN 60512-2-1:2002; IEC 60512-2-1:2002; DIN EN 60512-2-2:2004-01; EN 60512-2-2:2003; IEC 60512-2-2:2003; DIN EN 60512-3-1:2003-01; EN 60512-3-1:2002; IEC 60512-3-1:2002; DIN EN 60512-4-1:2003-01; EN 60512-4-1:2002; IEC 60512-4-1:2003; DIN EN 60068-2-1; IEC 60068-2-1; DIN EN 60068-2-2; IEC 60068-2-2; DIN EN 60068-2-14 (Nb); IEC 60068-2-14 (Nb); DIN EN 60068-2-30; IEC 60068-2-30; DIN EN 60068-2-38; IEC 60068-2-38; DIN EN 60068-2-78
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidanceCertificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.
IEC 60068-2-78; DIN EN 60068-2-14 Na, Nb; IEC 60068-2-14 Na, Nb; DIN EN 60068-2-6; IEC 60068-2-6; DIN EN 60068-2-64; IEC 60068-2-64; DIN EN 60068-2-27; IEC 60068-2-27; DIN EN 60068-2-31; DIN EN 60512-2-1; DIN EN 60512-2-2; DIN EN 60512-3-1
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
DIN EN 60512-2-1:2003-01; EN 60512-2-1:2002; IEC 60512-2-1:2002; DIN EN 60512-2-2:2004-01; EN 60512-2-2:2003; IEC 60512-2-2:2003; DIN EN 60512-3-1:2003-01; EN 60512-3-1:2002; IEC 60512-3-1:2002; DIN EN 60512-4-1:2003-01; EN 60512-4-1:2002; IEC 60512-4-1:2003; DIN EN 60068-2-1; IEC 60068-2-1; DIN EN 60068-2-2; IEC 60068-2-2; DIN EN 60068-2-14 (Nb); IEC 60068-2-14 (Nb); DIN EN 60068-2-30; IEC 60068-2-30; DIN EN 60068-2-38; IEC 60068-2-38; DIN EN 60068-2-78
IEC 60068-2-78; DIN EN 60068-2-14 Na, Nb; IEC 60068-2-14 Na, Nb; DIN EN 60068-2-6; IEC 60068-2-6; DIN EN 60068-2-64; IEC 60068-2-64; DIN EN 60068-2-27; IEC 60068-2-27; DIN EN 60068-2-31; DIN EN 60512-2-1; DIN EN 60512-2-2; DIN EN 60512-3-1
EN
EN 1434-4Name not checked yet
DIN EN IEC 61326 -3-2:2019-10; VDE 0843-20-3-2:2019-10; EN IEC 61326-3-2:2018; EN 61000-4-16; DIN EN 1434 -4:2023-03; EN 1434-4:2022; ETSI ES 201 468 V1.7.1; ETSI EN 300 386 V2.2.1; ETSI EN 301 489 -1 V2.2.3:2019-11; ETSI EN 301 489 -3 V2.3.2:2023-01
EN 50083-2Name not checked yet
DIN EN IEC 61000 -3-11:2021-03; VDE 0838-11:2021-03; EN IEC 61000-3-11:2019; IEC 61000 -3-12:2011 + AMD1:2021; DIN EN 61000 -3-12:2012-06; VDE 0838-12:2012-06; EN 61000-3-12:2011; DIN EN 50130 -4:2015-04; VDE 0830-1-4:2015-04; EN 50130-4:2011 + A1:2014; DIN EN 50155:2022-06; VDE 0115-200:2022-06; EN 50155:2021; DIN EN 50083 -2:2016-03; VDE 0855-200:2016-03; EN 50083-2:2012 + A1:2015
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
DIN EN IEC 61000-6-8; VDE 0839-6-8; EN IEC 61000-6-8; IEC 61000-6-8; DIN EN 50121-3-2; VDE 0115-121-3-2; EN 50121-3-2; A1; DIN EN 50121-4; A1; VDE 0115-121-4; A1; EN 50121-4; A1; CISPR 11; DIN EN 55011; VDE 0875-11; EN 55011; A1; CISPR 12; AMD1; DIN EN 55012; VDE 0879-1; EN 55012; IEC/CISPR 12; A1
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
DIN EN IEC 61000-6-8; VDE 0839-6-8; EN IEC 61000-6-8; IEC 61000-6-8; DIN EN 50121-3-2; VDE 0115-121-3-2; EN 50121-3-2; A1; DIN EN 50121-4; A1; VDE 0115-121-4; A1; EN 50121-4; A1; CISPR 11; DIN EN 55011; VDE 0875-11; EN 55011; A1; CISPR 12; AMD1; DIN EN 55012; VDE 0879-1; EN 55012; IEC/CISPR 12; A1
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
DIN EN IEC 61000 -3-11:2021-03; VDE 0838-11:2021-03; EN IEC 61000-3-11:2019; IEC 61000 -3-12:2011 + AMD1:2021; DIN EN 61000 -3-12:2012-06; VDE 0838-12:2012-06; EN 61000-3-12:2011; DIN EN 50130 -4:2015-04; VDE 0830-1-4:2015-04; EN 50130-4:2011 + A1:2014; DIN EN 50155:2022-06; VDE 0115-200:2022-06; EN 50155:2021; DIN EN 50083 -2:2016-03; VDE 0855-200:2016-03; EN 50083-2:2012 + A1:2015
EN 50155Railway applications - Rolling stock - Electronic equipment
DIN EN IEC 61000 -3-11:2021-03; VDE 0838-11:2021-03; EN IEC 61000-3-11:2019; IEC 61000 -3-12:2011 + AMD1:2021; DIN EN 61000 -3-12:2012-06; VDE 0838-12:2012-06; EN 61000-3-12:2011; DIN EN 50130 -4:2015-04; VDE 0830-1-4:2015-04; EN 50130-4:2011 + A1:2014; DIN EN 50155:2022-06; VDE 0115-200:2022-06; EN 50155:2021; DIN EN 50083 -2:2016-03; VDE 0855-200:2016-03; EN 50083-2:2012 + A1:2015
DIN EN 50155; DIN EN 60512-4-1
EN 50498Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles
DIN EN IEC 55025:2023 -11; VDE 0879-2:2023-11; EN IEC 55025:2022; CISPR 25:2021; ISO 10605:2008 + Cor.1:2010; DIN EN 50498:2011 -04; VDE 0879-498:2011-04; EN 50498:2010; ISO 11452 -1:2015; ISO 11452 -2:2019; ISO 11452 -4:2020; ISO 11452-4:2011; ISO 11452 -5:2002; ISO 11452 -8:2015; ISO 11452 -9:2021
IEC 61326 series
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
DIN EN 55020/A12:2017-01; VDE 0872-20/A2:2017-01; CISPR 20:2006 +AMD1:2013; CISPR 32:2015 + AMD 1:2019; DIN EN 55032:2022-08; VDE 0878-32:2022-08; CISPR 35:2016; DIN EN 55035:2018-04; VDE 0878-35:2018-04; DIN EN IEC 61326-1:2022-11; VDE 0843-20-1:2022-11; DIN EN IEC 61326-2-2: 2022-11; VDE 0843-20-2-2:2022-11
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
DIN EN 55020/A12:2017-01; VDE 0872-20/A2:2017-01; CISPR 20:2006 +AMD1:2013; CISPR 32:2015 + AMD 1:2019; DIN EN 55032:2022-08; VDE 0878-32:2022-08; CISPR 35:2016; DIN EN 55035:2018-04; VDE 0878-35:2018-04; DIN EN IEC 61326-1:2022-11; VDE 0843-20-1:2022-11; DIN EN IEC 61326-2-2: 2022-11; VDE 0843-20-2-2:2022-11
DIN EN IEC 61326-2-2; VDE 0843-20-2-2; EN IEC 61326-2-2; IEC 61326-2-2; DIN EN IEC 61326-2-3; VDE 0843-20-2-3; EN IEC 61326-2-3; IEC 61326-2-3; DIN EN IEC 61326-2-4; VDE 0843-20-2-4; EN IEC 61326-2-4; IEC 61326-2-4; DIN EN IEC 61326-2-5; VDE 0843-20-2-5; EN IEC 61326-2-5; IEC 61326-2-5; DIN EN 61326-3-1; VDE 0843-20-3-1; EN 61326-3-1; IEC 61326-3-1; EN 61000-4-16
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
DIN EN IEC 61326-2-2; VDE 0843-20-2-2; EN IEC 61326-2-2; IEC 61326-2-2; DIN EN IEC 61326-2-3; VDE 0843-20-2-3; EN IEC 61326-2-3; IEC 61326-2-3; DIN EN IEC 61326-2-4; VDE 0843-20-2-4; EN IEC 61326-2-4; IEC 61326-2-4; DIN EN IEC 61326-2-5; VDE 0843-20-2-5; EN IEC 61326-2-5; IEC 61326-2-5; DIN EN 61326-3-1; VDE 0843-20-3-1; EN 61326-3-1; IEC 61326-3-1; EN 61000-4-16
IEC 61326-2-4Name not checked yet
DIN EN IEC 61326-2-2; VDE 0843-20-2-2; EN IEC 61326-2-2; IEC 61326-2-2; DIN EN IEC 61326-2-3; VDE 0843-20-2-3; EN IEC 61326-2-3; IEC 61326-2-3; DIN EN IEC 61326-2-4; VDE 0843-20-2-4; EN IEC 61326-2-4; IEC 61326-2-4; DIN EN IEC 61326-2-5; VDE 0843-20-2-5; EN IEC 61326-2-5; IEC 61326-2-5; DIN EN 61326-3-1; VDE 0843-20-3-1; EN 61326-3-1; IEC 61326-3-1; EN 61000-4-16
IEC 61326-2-5Name not checked yet
DIN EN IEC 61326-2-2; VDE 0843-20-2-2; EN IEC 61326-2-2; IEC 61326-2-2; DIN EN IEC 61326-2-3; VDE 0843-20-2-3; EN IEC 61326-2-3; IEC 61326-2-3; DIN EN IEC 61326-2-4; VDE 0843-20-2-4; EN IEC 61326-2-4; IEC 61326-2-4; DIN EN IEC 61326-2-5; VDE 0843-20-2-5; EN IEC 61326-2-5; IEC 61326-2-5; DIN EN 61326-3-1; VDE 0843-20-3-1; EN 61326-3-1; IEC 61326-3-1; EN 61000-4-16
IEC 61326-3-1Name not checked yet
DIN EN IEC 61326-2-2; VDE 0843-20-2-2; EN IEC 61326-2-2; IEC 61326-2-2; DIN EN IEC 61326-2-3; VDE 0843-20-2-3; EN IEC 61326-2-3; IEC 61326-2-3; DIN EN IEC 61326-2-4; VDE 0843-20-2-4; EN IEC 61326-2-4; IEC 61326-2-4; DIN EN IEC 61326-2-5; VDE 0843-20-2-5; EN IEC 61326-2-5; IEC 61326-2-5; DIN EN 61326-3-1; VDE 0843-20-3-1; EN 61326-3-1; IEC 61326-3-1; EN 61000-4-16
IEC 61326-3-2Name not checked yet
DIN EN IEC 61326 -3-2:2019-10; VDE 0843-20-3-2:2019-10; EN IEC 61326-3-2:2018; EN 61000-4-16; DIN EN 1434 -4:2023-03; EN 1434-4:2022; ETSI ES 201 468 V1.7.1; ETSI EN 300 386 V2.2.1; ETSI EN 301 489 -1 V2.2.3:2019-11; ETSI EN 301 489 -3 V2.3.2:2023-01
ISO 11452 series
ISO 11452-1Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 1: General principles and terminology
DIN EN IEC 55025:2023 -11; VDE 0879-2:2023-11; EN IEC 55025:2022; CISPR 25:2021; ISO 10605:2008 + Cor.1:2010; DIN EN 50498:2011 -04; VDE 0879-498:2011-04; EN 50498:2010; ISO 11452 -1:2015; ISO 11452 -2:2019; ISO 11452 -4:2020; ISO 11452-4:2011; ISO 11452 -5:2002; ISO 11452 -8:2015; ISO 11452 -9:2021
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
DIN EN IEC 55025:2023 -11; VDE 0879-2:2023-11; EN IEC 55025:2022; CISPR 25:2021; ISO 10605:2008 + Cor.1:2010; DIN EN 50498:2011 -04; VDE 0879-498:2011-04; EN 50498:2010; ISO 11452 -1:2015; ISO 11452 -2:2019; ISO 11452 -4:2020; ISO 11452-4:2011; ISO 11452 -5:2002; ISO 11452 -8:2015; ISO 11452 -9:2021
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
DIN EN IEC 55025:2023 -11; VDE 0879-2:2023-11; EN IEC 55025:2022; CISPR 25:2021; ISO 10605:2008 + Cor.1:2010; DIN EN 50498:2011 -04; VDE 0879-498:2011-04; EN 50498:2010; ISO 11452 -1:2015; ISO 11452 -2:2019; ISO 11452 -4:2020; ISO 11452-4:2011; ISO 11452 -5:2002; ISO 11452 -8:2015; ISO 11452 -9:2021
ISO 11452-5Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 5: Stripline
DIN EN IEC 55025:2023 -11; VDE 0879-2:2023-11; EN IEC 55025:2022; CISPR 25:2021; ISO 10605:2008 + Cor.1:2010; DIN EN 50498:2011 -04; VDE 0879-498:2011-04; EN 50498:2010; ISO 11452 -1:2015; ISO 11452 -2:2019; ISO 11452 -4:2020; ISO 11452-4:2011; ISO 11452 -5:2002; ISO 11452 -8:2015; ISO 11452 -9:2021
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
DIN EN IEC 55025:2023 -11; VDE 0879-2:2023-11; EN IEC 55025:2022; CISPR 25:2021; ISO 10605:2008 + Cor.1:2010; DIN EN 50498:2011 -04; VDE 0879-498:2011-04; EN 50498:2010; ISO 11452 -1:2015; ISO 11452 -2:2019; ISO 11452 -4:2020; ISO 11452-4:2011; ISO 11452 -5:2002; ISO 11452 -8:2015; ISO 11452 -9:2021
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
DIN EN IEC 55025:2023 -11; VDE 0879-2:2023-11; EN IEC 55025:2022; CISPR 25:2021; ISO 10605:2008 + Cor.1:2010; DIN EN 50498:2011 -04; VDE 0879-498:2011-04; EN 50498:2010; ISO 11452 -1:2015; ISO 11452 -2:2019; ISO 11452 -4:2020; ISO 11452-4:2011; ISO 11452 -5:2002; ISO 11452 -8:2015; ISO 11452 -9:2021
ISO
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-2:2011; ISO 7637-3:2016; ISO/TS 7637-4:2020-05; ISO 16750-1:2018; ISO 16750-2:2012; ATIS 0600315:2018; SEMI F47-706:2012; IACS E10; TELCORDIA GR-1089-CORE, Issue 06:2013
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 7637-2:2011; ISO 7637-3:2016; ISO/TS 7637-4:2020-05; ISO 16750-1:2018; ISO 16750-2:2012; ATIS 0600315:2018; SEMI F47-706:2012; IACS E10; TELCORDIA GR-1089-CORE, Issue 06:2013
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
DIN EN IEC 55025:2023 -11; VDE 0879-2:2023-11; EN IEC 55025:2022; CISPR 25:2021; ISO 10605:2008 + Cor.1:2010; DIN EN 50498:2011 -04; VDE 0879-498:2011-04; EN 50498:2010; ISO 11452 -1:2015; ISO 11452 -2:2019; ISO 11452 -4:2020; ISO 11452-4:2011; ISO 11452 -5:2002; ISO 11452 -8:2015; ISO 11452 -9:2021
ISO 16750-1Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 1: General
ISO 7637-2:2011; ISO 7637-3:2016; ISO/TS 7637-4:2020-05; ISO 16750-1:2018; ISO 16750-2:2012; ATIS 0600315:2018; SEMI F47-706:2012; IACS E10; TELCORDIA GR-1089-CORE, Issue 06:2013
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 7637-2:2011; ISO 7637-3:2016; ISO/TS 7637-4:2020-05; ISO 16750-1:2018; ISO 16750-2:2012; ATIS 0600315:2018; SEMI F47-706:2012; IACS E10; TELCORDIA GR-1089-CORE, Issue 06:2013
IEC 60512 series
IEC 60512-2-1Name not checked yet
DIN EN 60512-2-1:2003-01; EN 60512-2-1:2002; IEC 60512-2-1:2002; DIN EN 60512-2-2:2004-01; EN 60512-2-2:2003; IEC 60512-2-2:2003; DIN EN 60512-3-1:2003-01; EN 60512-3-1:2002; IEC 60512-3-1:2002; DIN EN 60512-4-1:2003-01; EN 60512-4-1:2002; IEC 60512-4-1:2003; DIN EN 60068-2-1; IEC 60068-2-1; DIN EN 60068-2-2; IEC 60068-2-2; DIN EN 60068-2-14 (Nb); IEC 60068-2-14 (Nb); DIN EN 60068-2-30; IEC 60068-2-30; DIN EN 60068-2-38; IEC 60068-2-38; DIN EN 60068-2-78
IEC 60068-2-78; DIN EN 60068-2-14 Na, Nb; IEC 60068-2-14 Na, Nb; DIN EN 60068-2-6; IEC 60068-2-6; DIN EN 60068-2-64; IEC 60068-2-64; DIN EN 60068-2-27; IEC 60068-2-27; DIN EN 60068-2-31; DIN EN 60512-2-1; DIN EN 60512-2-2; DIN EN 60512-3-1
IEC 60512-2-2Name not checked yet
DIN EN 60512-2-1:2003-01; EN 60512-2-1:2002; IEC 60512-2-1:2002; DIN EN 60512-2-2:2004-01; EN 60512-2-2:2003; IEC 60512-2-2:2003; DIN EN 60512-3-1:2003-01; EN 60512-3-1:2002; IEC 60512-3-1:2002; DIN EN 60512-4-1:2003-01; EN 60512-4-1:2002; IEC 60512-4-1:2003; DIN EN 60068-2-1; IEC 60068-2-1; DIN EN 60068-2-2; IEC 60068-2-2; DIN EN 60068-2-14 (Nb); IEC 60068-2-14 (Nb); DIN EN 60068-2-30; IEC 60068-2-30; DIN EN 60068-2-38; IEC 60068-2-38; DIN EN 60068-2-78
IEC 60068-2-78; DIN EN 60068-2-14 Na, Nb; IEC 60068-2-14 Na, Nb; DIN EN 60068-2-6; IEC 60068-2-6; DIN EN 60068-2-64; IEC 60068-2-64; DIN EN 60068-2-27; IEC 60068-2-27; DIN EN 60068-2-31; DIN EN 60512-2-1; DIN EN 60512-2-2; DIN EN 60512-3-1
IEC 60512-3-1Name not checked yet
DIN EN 60512-2-1:2003-01; EN 60512-2-1:2002; IEC 60512-2-1:2002; DIN EN 60512-2-2:2004-01; EN 60512-2-2:2003; IEC 60512-2-2:2003; DIN EN 60512-3-1:2003-01; EN 60512-3-1:2002; IEC 60512-3-1:2002; DIN EN 60512-4-1:2003-01; EN 60512-4-1:2002; IEC 60512-4-1:2003; DIN EN 60068-2-1; IEC 60068-2-1; DIN EN 60068-2-2; IEC 60068-2-2; DIN EN 60068-2-14 (Nb); IEC 60068-2-14 (Nb); DIN EN 60068-2-30; IEC 60068-2-30; DIN EN 60068-2-38; IEC 60068-2-38; DIN EN 60068-2-78
IEC 60068-2-78; DIN EN 60068-2-14 Na, Nb; IEC 60068-2-14 Na, Nb; DIN EN 60068-2-6; IEC 60068-2-6; DIN EN 60068-2-64; IEC 60068-2-64; DIN EN 60068-2-27; IEC 60068-2-27; DIN EN 60068-2-31; DIN EN 60512-2-1; DIN EN 60512-2-2; DIN EN 60512-3-1
IEC 60512-4-1Name not checked yet
DIN EN 60512-2-1:2003-01; EN 60512-2-1:2002; IEC 60512-2-1:2002; DIN EN 60512-2-2:2004-01; EN 60512-2-2:2003; IEC 60512-2-2:2003; DIN EN 60512-3-1:2003-01; EN 60512-3-1:2002; IEC 60512-3-1:2002; DIN EN 60512-4-1:2003-01; EN 60512-4-1:2002; IEC 60512-4-1:2003; DIN EN 60068-2-1; IEC 60068-2-1; DIN EN 60068-2-2; IEC 60068-2-2; DIN EN 60068-2-14 (Nb); IEC 60068-2-14 (Nb); DIN EN 60068-2-30; IEC 60068-2-30; DIN EN 60068-2-38; IEC 60068-2-38; DIN EN 60068-2-78
DIN EN 50155; DIN EN 60512-4-1
Other standards
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
DIN EN 60601-1-2; IEC 60601-1-2
Scope as published by DAKKS
50 lines
ISO/IEC 17025
ActiveD-PL-12024-06-02
ISO/IEC 17025
ActiveD-PL-12024-06-03
ISO/IEC 17025
ActiveD-PL-12024-06-04
ISO/IEC 17025
ActiveD-PL-12024-06-05
ISO/IEC 17025
ActiveD-PL-12024-06-01
ISO/IEC 17025
ActiveD-PL-12024-06-00
Location
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in Germany
- Lynexo DeutschlandNürnberg · ~1 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Siemens Energy Global GmbH & Co. KG Materialprüflabor Siemens Trafowerk NürnbergNürnberg · ~8 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Chemisches Institut Burkon Partnerschaft - Partnerschaft von HandelschemikernNürnberg · ~8 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Forschung und Materialprüfung Nürnberg WilhelmNürnberg · ~9 kmDAKKSShares 1 accredited test methodEN ISO 9001
- LGA Bautechnik GmbH BautechnischesNürnberg · ~9 kmDAKKSShares 1 accredited test methodEN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.