UL Japan, Inc., Shonan EMC
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa, 259-1220, Japan, Kanagawa, Japan
- Accredited standards
- 73
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 73 standard numbers and the 36 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI30
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440
ETSI EN 301 441
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-5
Show all 30
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-20
ETSI EN 301 489-33
ETSI EN 301 893
ETSI EN 302 065-1
ETSI EN 302 065-2
ETSI EN 302 065-3-1
ETSI EN 302 208
ETSI EN 302 571
ETSI EN 303 345-1
ETSI EN 303 345-2
ETSI EN 303 345-3
ETSI EN 303 345-4
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI EN 303 687
ETSI EN 303 883
IEC 61000 series14
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR8
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CISPR 20
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national
National versions in the same scope
AS/NZS CISPR 32identical to it
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC7
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61131-2
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 62209-1
IEC 62209-2
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 63446
IEC 61326 series5
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
EN4
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50270
EN 50360
EN 50566
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
ASTM E2213
FCC PART 15Radio Frequency Devices
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETIS EN 300 330; ETSI EN 300 328; ETSI EN 300 440; ETSI EN 301 893; ETSI EN 302 208; ETSI EN 302 571; ETSI EN 303 417; ETSI EN 302 065-1; ETSI EN 302 065-2; ETSI EN 302 065-3; ETSI EN 302 065-3-1; ETSI EN 303 413; ETSI EN 303 883; ETSI EN 301 441; ETSI EN 303 345-1; ETSI EN 303 345-2; ETSI EN 303 345-3; ETSI EN 303 345-4; ETSI EN 303 687; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-5; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-20; ETSI EN 301 489-33; AS/NZS AS/NZS 4268; IEEE std. 1528; IEC 62311; EN 62311; EN IEC 62311; IEC 62209-1; EN 62209-1; IEC 62209-2; EN 62209-2; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; IEC/IEEE 63195-1; EN IEC/IEEE 63195-1; IEC PAS 63446; AS/NZS TS IEC 63446; KDB 865664; RSS-102; RSS-102.SAR.MEAS; RSS-102.NS.MEAS; Radiocommunications Equipment (General) Rules 2021 Part 4 Schedule 4; ARPANSA Standard Means the Radiation Protection Standard for Limiting Exposure to Radiofrequency Fields – 100 kHz to 300 GHz; EN 50360; EN 50566; ISO 7637-2
47 CFR FCC Part 15, Subpart B; ANSI C63.4:2014; 47 CFR FCC Part 18; FCC OST/MP-5 (1986); ICES-001; ICES-003; CISPR 11; EN 55011; SANS 211; CISPR 13; EN 55013; CISPR 15; EN 55015; EN IEC 55015; SANS 215; CISPR 22; EN 55022; CISPR 32; EN 55032; AS/NZS CISPR 32; SANS 2332; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; SANS 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; SANS 61000-6-4; VCCI-CISPR32; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; SANS 61000-3-2; IEC 61000-3-3; EN 61000-3-3; SANS 61000-3-3; IEC 61000-4-2; EN 61000-4-2; SANS 61000-4-2; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; SANS 61000-4-3; IEC 61000-4-4; EN 61000-4-4; SANS 61000-4-4; IEC 61000-4-5; EN 61000-4-5; SANS 61000-4-5; IEC 61000-4-6; EN 61000-4-6; EN IEC 61000-4-6; SANS 61000-4-6
IEC 61000-4-8; EN 61000-4-8; SANS 61000-4-8; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; SANS 61000-4-11; IEC 61000-4-39; EN 61000-4-39; CISPR 20; EN 55020; CISPR 24; EN 55024; CISPR 35; EN 55035; SANS 2335; IEC 61547; EN 61547; SANS 61547; IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; SANS 61000-6-1; IEC 61000-6-2; EN 61000-6-2; EN IEC 61000-6-2; SANS 61000-6-2; IEC 61131-2; EN 61131-2; SANS 61131-2; EN 50270; EN 50130-4; IEC 61326-1; EN 61326-1; EN IEC 61326-1; SANS 61326-1; IEC 61326-2-1; EN 61326-2-1; EN IEC 61326-2-1; IEC 61326-2-2; EN 61326-2-2; EN IEC 61326-2-2; IEC 61326-2-3; EN 61326-2-3; EN IEC 61326-2-3; SANS 61326-2-3; IEC 61326-2-6; EN 61326-2-6; EN IEC 61326-2-6; IEC 60601-1-2; EN 60601-1-2; SANS 60601-1-2; ANSI C63.4; ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.26; ANSI/TIA-603E; ASTM E2213-03; ANSI/TIA-102.CAAA-E; FCC KDB 905462 D02v02; CFR 47 FCC Part 15 Subpart C; CFR 47 FCC Part 15 Subpart E; CFR 47 FCC Part 15 Subpart F; CFR 47 FCC Part 22; CFR 47 FCC Part 24; CFR 47 FCC Part 25; CFR 47 FCC Part 27; CFR 47 FCC Part 30; CFR 47 FCC Part 73; CFR 47 FCC Part 74; CFR 47 FCC Part 80; CFR 47 FCC Part 87; CFR 47 FCC Part 90; CFR 47 FCC Part 95; CFR 47 FCC Part 97; CFR 47 FCC Part 101; RSS-GEN; RSS-119; RSS-132; RSS-133; RSS-141; RSS-210; RSS-216; RSS-220; RSS-238; RSS-247; RSS-248; RSS-310
ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; IEEE Std 1528:2013; IEC 60601-1-2 Edition 4.1 2020-09 CONSOLIDATED VERSION
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active1266.03
The scope document we hold says it is valid until 2027-01-31.
Accredited scope, certificate 1266.03
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | 47 CFR FCC Part 15, Subpart B; ANSI C63.4:2014; 47 CFR FCC Part 18; FCC OST/MP-5 (1986); ICES-001; ICES-003; CISPR 11; EN 55011; SANS 211; CISPR 13; EN 55013; CISPR 15; EN 55015; EN IEC 55015; SANS 215; CISPR 22; EN 55022; CISPR 32; EN 55032; AS/NZS CISPR 32; SANS 2332; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; SANS 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; SANS 61000-6-4; VCCI-CISPR32; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; SANS 61000-3-2; IEC 61000-3-3; EN 61000-3-3; SANS 61000-3-3; IEC 61000-4-2; EN 61000-4-2; SANS 61000-4-2; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; SANS 61000-4-3; IEC 61000-4-4; EN 61000-4-4; SANS 61000-4-4; IEC 61000-4-5; EN 61000-4-5; SANS 61000-4-5; IEC 61000-4-6; EN 61000-4-6; EN IEC 61000-4-6; SANS 61000-4-6 | Medical equipment, electrical safety and EMC | to 40 GHz |
| 2 | IEC 61000-4-8; EN 61000-4-8; SANS 61000-4-8; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; SANS 61000-4-11; IEC 61000-4-39; EN 61000-4-39; CISPR 20; EN 55020; CISPR 24; EN 55024; CISPR 35; EN 55035; SANS 2335; IEC 61547; EN 61547; SANS 61547; IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; SANS 61000-6-1; IEC 61000-6-2; EN 61000-6-2; EN IEC 61000-6-2; SANS 61000-6-2; IEC 61131-2; EN 61131-2; SANS 61131-2; EN 50270; EN 50130-4; IEC 61326-1; EN 61326-1; EN IEC 61326-1; SANS 61326-1; IEC 61326-2-1; EN 61326-2-1; EN IEC 61326-2-1; IEC 61326-2-2; EN 61326-2-2; EN IEC 61326-2-2; IEC 61326-2-3; EN 61326-2-3; EN IEC 61326-2-3; SANS 61326-2-3; IEC 61326-2-6; EN 61326-2-6; EN IEC 61326-2-6; IEC 60601-1-2; EN 60601-1-2; SANS 60601-1-2; ANSI C63.4; ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.26; ANSI/TIA-603E; ASTM E2213-03; ANSI/TIA-102.CAAA-E; FCC KDB 905462 D02v02; CFR 47 FCC Part 15 Subpart C; CFR 47 FCC Part 15 Subpart E; CFR 47 FCC Part 15 Subpart F; CFR 47 FCC Part 22; CFR 47 FCC Part 24; CFR 47 FCC Part 25; CFR 47 FCC Part 27; CFR 47 FCC Part 30; CFR 47 FCC Part 73; CFR 47 FCC Part 74; CFR 47 FCC Part 80; CFR 47 FCC Part 87; CFR 47 FCC Part 90; CFR 47 FCC Part 95; CFR 47 FCC Part 97; CFR 47 FCC Part 101; RSS-GEN; RSS-119; RSS-132; RSS-133; RSS-141; RSS-210; RSS-216; RSS-220; RSS-238; RSS-247; RSS-248; RSS-310 | - | to 26 MHz |
| 3 | ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETIS EN 300 330; ETSI EN 300 328; ETSI EN 300 440; ETSI EN 301 893; ETSI EN 302 208; ETSI EN 302 571; ETSI EN 303 417; ETSI EN 302 065-1; ETSI EN 302 065-2; ETSI EN 302 065-3; ETSI EN 302 065-3-1; ETSI EN 303 413; ETSI EN 303 883; ETSI EN 301 441; ETSI EN 303 345-1; ETSI EN 303 345-2; ETSI EN 303 345-3; ETSI EN 303 345-4; ETSI EN 303 687; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-5; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-20; ETSI EN 301 489-33; AS/NZS AS/NZS 4268; IEEE std. 1528; IEC 62311; EN 62311; EN IEC 62311; IEC 62209-1; EN 62209-1; IEC 62209-2; EN 62209-2; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; IEC/IEEE 63195-1; EN IEC/IEEE 63195-1; IEC PAS 63446; AS/NZS TS IEC 63446; KDB 865664; RSS-102; RSS-102.SAR.MEAS; RSS-102.NS.MEAS; Radiocommunications Equipment (General) Rules 2021 Part 4 Schedule 4; ARPANSA Standard Means the Radiation Protection Standard for Limiting Exposure to Radiofrequency Fields – 100 kHz to 300 GHz; EN 50360; EN 50566; ISO 7637-2 | - | - |
| 4 | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015 | - | to 40000 MHz |
| 5 | ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; IEEE Std 1528:2013; IEC 60601-1-2 Edition 4.1 2020-09 CONSOLIDATED VERSION | - | to 40000 MHz |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
UL JAPAN, INC., SHONAN EMC LABORATORY
Kanagawa, Japan
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This laboratory also meets A2LA R256
– Specific Requirements FDA ASCA Program. This accreditation demonstrates technical competence for a defined
scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 23rd day of January 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1266.03
Valid to January 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa, 259-1220, Japan, Kanagawa, JP
35.43429, 139.37475
Open in MapsLabs with overlapping accredited scope in Japan
- UL JapanIse-shi, Mie · ~263 kmA2LAShares 3 accredited methods and materialsANSI C63.4:2014ANSI/TIA-603-EMedical equipment, electrical safety and EMC
- UL Japan, Inc. - Kashima EMCChiba-ken, 289-0341 · ~66 kmA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 61000-4-8
- TUV SUD Japan Ltd. Yonezawa Testing Center (EMC Lab)Yamagata · ~344 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- TUV SUD JapanTokyo · ~44 kmA2LAShares 1 accredited materialMedical equipment, electrical safety and EMC
- QSES Inc. Testing LaboratoryAbiko-Shi, Chiba · ~76 kmA2LAShares 1 accredited test methodIEC 61000-4-8
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.