FUKUDA USA
2721 Pioneer Drive, 42101, Bowling Green, KY, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 2788.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2788.01) 06/25/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
FUKUDA USA, INC.
2721 Pioneer Drive
Bowling Green, KY 42101
Brennan Clark Phone: 270 745 7300
CALIBRATION
Valid To: April 30, 2027 Certificate Number: 2788.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Fluid Quantities
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Flow3 – Measuring
Equipment
(0.010 to 0.500) ml/min
(0.500 to 1.000) ml/min
(1.000 to 10.00) ml/min
(10.00 to 100.0) ml/min
(100.0 to 200.0) ml/min
0.02 ml/min
0.02 ml/min
0.07 ml/min
1.1 ml/min
2.5 ml/min
Flow measuring
device
Flow3 – Mass/Laminar
(0.0 to 500.0) ml/min
(0.500 to 10.0) LPM
(10.0 to 500.0) LPM
3.0 ml/min
0.06 LPM
3.9 LPM
Flow measuring
device | 0 to 500 LPM |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2788.01) 06/25/2025 Page 2 of 2
II. Mechanical
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Pressure3 – Measuring
Equipment
Gauges
Transducers with Digital
Readouts
(-100 to 2068) kPa
(-100 to 2068) kPa
Up to 10 000 PSI
0.98 kPa
0.98 kPa
14 psi
Pressure measuring
device
Hydraulic pressure
measuring device
Leak Testers3 –
Differential Pressure
Decay
Gauge/Pressure Decay
(-34 to 35) kPa
(-100 to 6894) kPa
0.001 kPa
0.6 kPa
Pressure measuring
device
____________________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This laboratory performs field calibration activities for these parameters. Please note the actual
measurement uncertainties achievable on a customer's site can normally be expected to be larger than the
CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the
place of calibration and for othe r possible adverse effects such as those caused by transportation of the
calibration equipment. The usual allowance for the actual uncertainty introduced by the item being
calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual
measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | -100 to 2068 kPa |
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.