Luxshare Precision Mexico
Av Chilpancingo 52, Tijuana, 22446, Mexico, Tijuana, Mexico
- Accredited standards
- 21
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 21 standard numbers and the 20 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068 series9
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ISO3
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 16750 series3
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
Other standards2
ASTM D5276
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14; ISO 16750-4; IEC 60068-2-30; IEC 60068-2-38; IEC 60068-2-78; IEC 60529; GMW 14834; IEC 60068-2-6; IEC 60068-2-64; ISO 16750-3; IEC 60068-2-27; ASTM D 5276; ISTA 1A; ISTA 1E
ISO 11452-2; ISO 11452-2 (2019); ISO 11452-4; ISO 11452-4 (2020); ISO 11452-8; ISO 11452-8 (2015); ISO 11452-9; ISO 11452-9 (2012); CISPR 25; CISPR 25 (2016)
ISO 10605; ISO 16750-2; ISO 7637-2; ISO 7637-3
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-06.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active6771.01
The scope document we hold says it is valid until 2027-05-31.
Accredited scope, certificate 6771.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 11452-2; ISO 11452-2 (2019); ISO 11452-4; ISO 11452-4 (2020); ISO 11452-8; ISO 11452-8 (2015); ISO 11452-9; ISO 11452-9 (2012); CISPR 25; CISPR 25 (2016) | Road Vehicles | - |
| 2 | ISO 10605; ISO 16750-2; ISO 7637-2; ISO 7637-3 | - | - |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active6771.03
The scope document we hold says it is valid until 2027-05-31.
Accredited scope, certificate 6771.03
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14; ISO 16750-4; IEC 60068-2-30; IEC 60068-2-38; IEC 60068-2-78; IEC 60529; GMW 14834; IEC 60068-2-6; IEC 60068-2-64; ISO 16750-3; IEC 60068-2-27; ASTM D 5276; ISTA 1A; ISTA 1E | automotive electronic and electrical devices | -65 to 155 °C |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. For the types of tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
LUXSHARE PRECISION MEXICO
Tijuana, Mexico
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 29th day of May 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6771.03
Valid to May 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.