Zetec, Incorporated

8226 Bracken Place SE, Suite 100, 98065, Snoqualmie, WA, United States

Visit website
A2LA 2734.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
10
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 10 scope lines.

A2LA certificate 2734.01 · 10 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.01) 07/21/2025 Page 1 of 9 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ZETEC, INCORPORATED 8226 Bracken Place SE, Suite 100 Snoqualmie, WA 98065 James Larsen Phone: 425 974 2829 CALIBRATION Valid To: August 31, 2027 Certificate Number: 2734.01 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 7: I. Electrical – DC/Low Frequency Parameter/Equipment Frequency CMC2, 6 (±) Comments AC Voltage – Measure Fixed Points 100 mVrms 10 Hz to 20 kHz 0.12 % + 35 µV Agilent 34410A & 34465A II. Magnetic – Eddy Current Instrumentation (MIZ-8xiDSeries & MIZ-200iD) Parameter/Equipment Range5 CMC2, 4 (±) Comments Receiver Amplifier Linearity – Eddy Current Instrumentation3 (0 to 100) % of Full Scale 0.51 % Agilent 33250A & 33600A Receiver Quadrature – Eddy Current Instrumentation3 (0 to 360)° 0.024° ZETEC ACM, Agilent 33250A & 33600A Receiver Gain – Eddy Current Instrumentation3 (0 to 80) dB 0.14 % ZETEC ACM, Agilent 33250A & 33600A
0 to 100 %
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.01) 07/21/2025 Page 2 of 9 Parameter/Equipment Range CMC2, 4 (±) Comments Coil Driver Frequency – Eddy Current Instrumentation3 10 Hz to 6 MHz 0.12 % ZETEC ACM, Agilent 53132A Receiver Frequency Bandwidth – Eddy Current Instrumentation 3 (8 to 5000) Hz 0.24 % Agilent 33250A & 33600A III. Time & Frequency Parameter/Range Range CMC2, 4, 8 (±) Comments Frequency – Measure3 (10 to 100) mVrms 40 Hz to 300 kHz 0.12 % + 250 µHz Agilent 34410A & 34465A IV. Time & Frequency (Ultrasound Instrumentation – Dynaray Series) Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 Frequency Response: Low Cutoff High Cutoff Bandwidth (0.225 to 20) MHz None, HP1M, HP2M, HP5M, HP10M, LP2M < 2.2 % , All others < 0.90 % None, BP1-5M, HP1M, LP2M, LP5M, LP10M, LP15M < 6.5 % , All others < 1.9 % None, HP1M, HP2M, HP10M, LP2M, LP15M < 2.5 % , All others < 1.0 % Agilent 33250A & 33600A, Tektronix TDS-3032/3054 (A, B, or C), ZETEC attenuator 10040260, ZETEC ABUXE127A
10 to 6000000 Hz
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.01) 07/21/2025 Page 3 of 9 Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 Frequency Response: Center Linearity of Time Delays Gain Linearity Channel Gain Variation Linearity of Vertical Display Equivalent Input Noise Up to 50 µs (0 to 80) dB < 1.5 dB (Zetec) (0 to 28) dB rel. < 80 nV/√Hz None < 3.6 % All others < 1.8 % 0.0063 % 0.47 dB 0.65 dB 0.53 % 7.0 nV/√Hz Agilent 33250A & 33600A, Tektronix TDS-3032/3054 (A, B, or C), ZETEC attenuator 10040260, ZETEC ABUXE127A Transmitter – Ultrasound Instrumentation3 Voltage Rise Time Duration Linearity of Time Delays (25 to 250) V Up to 50 ns (25 to 1000) ns Up to 50 µs 1.8 % 0.78 ns 0.46 ns 0.070 % Agilent 33250A & 33600A, Tektronix TDS-3032/3054 (A, B, or C), ZETEC ABUXE 127A, 50 ohms/ 10W load
to 50 µs
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.01) 07/21/2025 Page 4 of 9 V. Time & Frequency (Ultrasound Instrumentation – Zircon-15, Zircon-18, Topaz16, Topaz32, Quartz) Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 Frequency Response – Zircon-15, Zircon-18, Topaz32, Quartz: Phased Array Low Cutoff High Cutoff Bandwidth Center Conventional Low Cutoff High Cutoff Bandwidth Center Zircon-15 (0.50 to 15) MHz Zircon-18, Topaz32, Quartz (0.50 to 18) MHz < 0.70 % HP1M ≤ 3.2 % None, LP5M, LP10M, HP2M ≤ 2.4 % All others ≤ 1.5 % < 0.80 % < 0.90 % < 0.70 % HP1M ≤ 8.0 % , None, HP2M ≤ 5.2 % LP5M, LP10M, BP1- 5M, BP2-10M ≤ 1.9 % All others ≤ 0.90 % < 0.90 % LP5M, HP1M ≤ 1.3 % All others ≤ 1.0 % Agilent 33250A &33600A, Tektronix TDS-3032/3054 (A, B, or C), ZETEC attenuator 10040260, ZETEC 10040371 (ZIF) ZETEC 10059869 (IPEX)
0.5 to 18 MHz
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.01) 07/21/2025 Page 5 of 9 Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 (cont) Frequency Response – Topaz16: Phased Array Low Cutoff High Cutoff Bandwidth Center Conventional Low Cutoff High Cutoff Bandwidth Center Linearity of Time Delays Gain Linearity – Phased Array Conventional (0.50 to 18) MHz Up to 20 µs (0 to 70) dB (0 to 70) dB < 0.80 % None, LP2M, LP5M, LP10M, HP1M, HP2M < 2.3 % , All others < 1.4 % LP2M < 1.1 % , All others < 0.90 % None, LP2M, LP5M < 1.4 % , All others < 1.0 % < 1.0 % None, HP1M, HP2M < 6.5 % LP2M, LP5M, LP10M, HP5M, BP1-5M, BP5-18M < 3.0 % , All others < 1.7 % LP2M, BP5-18M, BP10- 18M < 1.6 % , All others < 1.0 % None, LP2M, BP5-18M < 1.9 % , All others < 1.0 % 0.014 % 0.29 dB 0.27 dB Agilent 33250A & 33600A, Tektronix TDS- 3032/3054 (A, B, or C), ZETEC attenuator 10040260, ZETEC 10040371(ZIF), ZETEC 10059869 (IPEX)
0.5 to 18 MHz
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.01) 07/21/2025 Page 6 of 9 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Receiver – Ultrasound Instrumentation3 (cont) Channel Gain Variation – Phased Array Conventional Linearity of Vertical Display Equivalent Input Noise < 1.5 dB (Zetec) < 1.5 dB (Zetec) 28 dB rel. < 80 nV/√Hz 0.40 dB 0.38 dB 0.36 % 3.3 nV/√Hz Agilent 33250A & 33600A, Tektronix TDS- 3032/3054 (A, B, or C), ZETEC attenuator 10040260, ZETEC 10040371 (ZIF), ZETEC 10059869 (IPEX) Transmitter – Ultrasound Instrumentation3 Voltage – Phased Array Conventional Rise Time – Phased Array Conventional Duration – Phased Array Conventional Linearity of Time Delays (35 to 75) V (50 to 200) V Up to 50 ns Up to 50 ns (25 to 500) ns (25 to 500) ns Up to 20 µs 2.0 % 2.6 % 0.57 ns 0.34 ns 0.51 ns 0.48 ns 0.051 % Agilent 33250A & 33600A, Tektronix TDS- 3032/3054 (A, B, or C), ZETEC 10040371 (ZIF), ZETEC 10059869 (IPEX)
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.01) 07/21/2025 Page 7 of 9 VI. Time & Frequency (Ultrasound Instrumentation – Topaz64, Emerald64) Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 Frequency Response: Phased Array Low Cutoff High Cutoff Bandwidth Center Conventional Low Cutoff High Cutoff Bandwidth Center (0.50 to 18) MHz HP0.6M, LP2M, LP5M, LP10M, HP1M, BP1-5M: < ±6.5 % HP2M, BP1.75-7M, BP2-10M: < ±3.4 % All others: < ±1.7 % HP0.6M, LP2M, LP5M, LP10M, BP1-5M:< ±2.5 % All others: < ±1.1 % HP0.6M, LP2M, LP5M, BP1- 5M, BP5-10M: < ±3.6 % All others: < ±1.9 % HP0.6M, LP2M, LP5M, LP10M, BP1-5M, BP1.75-7M: < ±4.3 % All others: < ±1.9 % LP2M, BP1-4M, BP1.125-4.5M, BP1.875-7.5M, BP5-20M, BP0.55-6M: < ±4.2 % All others: < ±3.0 % LP2M, BP1-4M, HP3M: < ±2.1 % All others: < ±1.2 % LP2M, BP1-4M, BP2-8M, BP5- 20M, HP10M: < ±3.1 % All others: < ±2.0 % LP2M, BP1-4M, BP1.125-4.5M, BP2-8M, HP10M, HP3M, BP0.55-6M: < ±3.7 % All others: < ±2.0 % Agilent 33250A, Tektronix TDS- 3032 (A, B, or C), MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF) ZETEC 10059869 (IPEX)
0.5 to 18 MHz
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.01) 07/21/2025 Page 8 of 9 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Receiver – Ultrasound Instrumentation3 (cont) Linearity of Time Delays Gain Linearity – Phased Array Conventional Channel Gain Variation – Phased Array Conventional Linearity of Vertical Display Equivalent Input Noise Phased Array Conventional Up to 20 µs (0 to 70) dB (0 to 70) dB < 1.5 dB (Zetec) < 1.5 dB (Zetec) 28 dB rel. < 80 nV/√Hz 0.088 % 0.29 dB 0.27 dB 0.41 dB 0.37 dB 1.2 % 9.0 nV/√Hz 28 nV/√Hz Agilent 33250A, Tektronix TDS-3032 (A, B, or C), MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF), ZETEC 10059869 (IPEX) Transmitter – Ultrasound Instrumentation3 Voltage Phased Array Conventional Rise Time Phased Array Conventional Duration Phased Array Conventional Linearity of Time Delays (10 to 75) V (20 to 200) V Up to 50 ns Up to 50 ns (25 to 500) ns (25 to 500) ns Up to 20 µs 2.2 % 2.7 % 0.57 ns 0.34 ns 0.49 ns 0.57 ns 0.056 % Agilent 33250A, Tektronix TDS-3032 (A, B, or C), MDO3032, MDO32, ZETEC 10040371 (ZIF) ZETEC 10059869 (IPEX) 50 ohms/10W load
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.01) 07/21/2025 Page 9 of 9 _______________________ 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages represent percent of reading unless otherwise noted. 5 References to decibels (dB) refer to dB in voltage. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 This scope meets A2LA’s P112 Flexible Scope Policy. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
10

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited ZETEC, INCORPORATED Snoqualmie, WA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 21st day of July 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2734.01 Valid to August 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

8226 Bracken Place SE, Suite 100, Snoqualmie, WA, 98065, US

47.52895, -121.82709

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.