Keithley Instruments Germany
Landsberger Strasse 65, 82110 Germering, Germany, 82110 Germering, Germany
Visit website- Scope lines
- 11
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 11 scope lines.
A2LA certificate 2611.01 · 11 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2611.01) 07/28/2025 Page 1 of 10
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
KEITHLEY INSTRUMENTS GERMANY
Landsberger Str. 65
82110 Germering, GERMANY
Thomas Worm Phone: +49 (89) 84 93 07 -35
CALIBRATION
Valid To: September 30, 2027 Certificate Number: 2611.01
In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1:
I. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC
2 (±)
Comments
DC Voltage – Generate
6
Fixed Point
(0.001 to 0.004) V
(0.004 to 0.01) V
(0 to 0.22) V
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
(300 to 3000) V
10 V
27 µV/V
20 µV/V
6.0 µV/V + 0.40 µV
3.5 µV/V + 0.70 µV
2.5 µV/V + 2.5 µV
2.5 µV/V + 4.1 µV
3.5 µV/V + 40 µV
4.5 µV/V + 0.40 mV
59 µV/V + 30 mV
0.72 µV/V
Fluke 5730A (based
on 90 day specs) into
Keithley 262 divider
Fluke 5730A
(based on 90 day
specs)
Characterized
Keithley 2657A,
Keithley 2002
Fluke 7001
DC Voltage – Generate
3
(0 to 0.2) V
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(300 to 3000) V
23 µV/V + 49 µV
13 µV/V + 52 µV
15 µV/V + 60 µV
26 µV/V + 0.73 mV
59 µV/V + 30 mV
Voltage source
Keithley 2002
Characterized
Keithley 2657A,
Keithley 2002 | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2611.01) 07/28/2025 Page 2 of 10
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Voltage – Measure
5, 6
(0.001 to 0.1) V
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 500) V
(500 to 1000) V
(300 to 3000) V
14 µV/V + 0.42 µV
12 µV/V + 0.42 µV
12 µV/V + 0.90 µV
14 µV/V + 42 µV
18 µV/V + 0.15 mV
28 µV/V + 0.15 mV
59 µV/V + 25 mV
Agilent 3458A
Voltage divider &
Keithley 2002
DC Voltage – Measure3
(0 to 0.2) V
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(300 to 3000) V
23 µV/V + 19 µV
13 µV/V + 20 µV
15 µV/V + 24 µV
26 µV/V + 0.66 mV
59 µV/V + 25 mV
Keithley 2002
Voltage divider &
Keithley 2002
DC Current – Generate4, 6
Pulsed (1 ms Max)
(0.2 to 2) pA
(2 to 20) pA
(20 to 200) pA
(0.2 to 2) nA
(2 to 20) nA
(20 to 200) nA
(5 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 1) A
(1 to 2.2) A
(2.2 to 5) A
(1 to 10) A
(10 to 20) A
(20 to 50) A
0.075 % + 4.1 fA
0.075 % + 4.1 fA
0.021 % + 41 fA
0.021 % + 41 fA
0.018 % + 0.41 pA
0.014 % + 4.1 pA
41 µA/A + 59 pA
29 µA/A + 74 pA
29 µA/A + 0.15 µA
35 µA/A + 6.0 nA
30 µA/A + 7.0 nA
30 µA/A + 41 nA
40 µA/A + 0.70 µA
60 µA/A + 12 µA
0.011 % + 12 µA
0.034 % + 0.48 mA
76 µA/A + 2.0 mA
76 µA/A + 3.5 mA
95 µA/A + 3.2 mA
Keithley 5156, Fluke
5730A (based on 90
day specs)
Auxiliary current
source characterized
with Agilent 3458A
Fluke 5730A
(based on 90 day
specs)
Fluke 5730A/5725A
Agilent 3458A, 0.1 Ω
shunt | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2611.01) 07/28/2025 Page 3 of 10
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Current – Generate3
(0 to 1) pA
(1 to 10) pA
(10 to 100) pA
(0.1 to 1) nA
(1 to 10) nA
(10 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
0.12 % + 2.2 fA
0.12 % + 2.3 fA
0.024 % + 17 fA
0.012 % + 34 fA
0.012 % + 90 fA
0.012 % + 0.44 pA
0.012 % + 3.9 pA
0.012 % + 37 pA
82 µA/A + 0.30 nA
82 µA/A + 3.0 nA
93 µA/A + 30 nA
0.012 % + 0.30 µA
0.024 % + 5.5 µA
Keithley 2002
Keithley 7177
current source
DC Current – Measure5, 6
Pulsed (1 ms Max)
(0.1 to 1) pA
(1 to 10) pA
(10 to 100) pA
(0.1 to 1) nA
(1 to 10) nA
(10 to 100) nA
(0 to 100) nA
(0.1 to 1) ) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1.1) A
(1.1 to 5) A
(1 to 10) A
(10 to 20) A
(20 to 50) A
0.075 % + 4.1 fA
0.075 % + 4.1 fA
0.022 % + 41 fA
0.022 % + 42 fA
0.018 % + 0.43 pA
0.015 % + 4.2 pA
41 µA/A + 59 pA
29 µA/A + 59 pA
29 µA/A + 0.13 nA
29 µA/A + 1.1 nA
29 µA/A + 7.0 nA
29 µA/A + 70 nA
47 µA/A + 0.70 µA
0.014 % + 13 µA
69 µA/A + 6.0 µA
76 µA/A + 10 mA
76 µA/A + 11 mA
95 µA/A + 11 mA
Keithley 5156
Agilent 3458A
Agilent 3458A
KI 2300-RBOX
with Agilent 3458A
Agilent 3458A, 0.1 Ω
shunt
DC Current – Measure
3
(0 to 1) pA
(1 to 10) pA
(10 to 100) pA
(0.1 to 1) nA
(1 to 10) nA
(10 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
0.12 % + 2.2 fA
0.12 % + 2.3 fA
0.024 % + 17 fA
0.012 % + 34 fA
0.012 % + 89 fA
0.012 % + 0.43 pA
0.012 % + 3.8 pA
0.012 % + 37 pA
82 µA/A + 0.29 nA
82 µA/A + 2.9 nA
93 µA/A + 29 nA
0.012 % + 0.30 µA
0.024 % + 5.1 µA
Keithley 2002
Keithley 7177 | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2611.01) 07/28/2025 Page 4 of 10
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Resistance –
Generate
4, 6
Fixed Points
1 Ω
10 kΩ
900 MΩ
1 GΩ
10 GΩ
100 GΩ
0 Ω
(1, 1.9) Ω
(10, 19) Ω
(100, 190) Ω
(1, 1.9) kΩ
(10, 19) k Ω
(100, 190) kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
0.69 µΩ/Ω
1.4 µΩ/Ω
0.032 %
0.018 %
0.021 %
0.073 %
40 µΩ
80 µΩ/Ω
21 µΩ/Ω
9.0 µΩ/Ω
7.5 µΩ/Ω
7.5 µΩ/Ω
9.0 µΩ/Ω
15 µΩ/Ω
16 µΩ/Ω
32 µΩ/Ω
39 µΩ/Ω
95 µΩ/Ω
Fluke 742A-1
Fluke 742A-10k
Keithley 2001-758D
Keithley 5156-1G,
Keithley 5156-10G,
Keithley 5156-100G,
Fluke 5730A
(based on 90 day
specs)
DC Resistance –
Measure
5
(0 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
(0.2 to 2) kΩ
(2 to 20) kΩ
(20 to 200) kΩ
(0.2 to 2) MΩ
(2 to 20) MΩ
(20 to 200) MΩ
(0.2 to 2) GΩ
17 µΩ/Ω + 4.0 µΩ
9.5 µΩ/Ω + 15 µΩ
8.0 µΩ/Ω + 50 µΩ
8.0 µΩ/Ω + 0.51 mΩ
8.0 µΩ/Ω + 5.0 mΩ
8.0 µΩ/Ω + 50 mΩ
9.0 µΩ/Ω + 1.0 Ω
20 µΩ/Ω + 0.10 kΩ
0.012 % + 10 kΩ
0.16 % + 1.0 MΩ
Fluke 8508A | to 100 GΩ |
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2611.01) 07/28/2025 Page 5 of 10
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Generate
6
(10 to 220) µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.023 % + 16 nA
0.014 % + 10 nA
0.011 % + 8.0 nA
0.025 % + 12 nA
0.090 % + 65 nA
0.023 % + 41 nA
0.014 % + 35 nA
0.011 % + 35 nA
0.018 % + 0.11 µA
0.090 % + 0.65 µA
0.023 % + 0.41 µA
0.014 % + 0.36 µA
0.011 % + 0.35 µA
0.018 % + 0.55 µA
0.090 % + 5.0 µA
0.023 % + 4.0 µA
0.014 % + 3.6 µA
0.011 % + 2.5 µA
0.018 % + 3.5 µA
0.090 % + 10 µA
0.024 % + 36 µA
0.039 % + 81 µA
0.60 % + 0.16 mA
0.040 % + 0.18 mA
0.085 % + 0.38 mA
0.33 % + 0.75 mA
Fluke 5730A
(based on 90 day
specs)
With Fluke 5725A
(based on 90 day
specs)
AC Current – Measure6
(5 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
0.47 % + 35 nA
0.18 % + 35 nA
0.069 % + 35 nA
0.069 % + 35 nA
0.47 % + 0.24 µA
0.18 % + 0.23 µA
0.069 % + 0.23 µA
0.035 % + 0.23 µA
0.47 % + 2.3 µA
0.18 % + 2.3 µA
0.069 % + 2.3 µA
0.035 % + 2.3 µA
Agilent 3458A (based
on 2 year specs) | 10 to 11 A |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2611.01) 07/28/2025 Page 6 of 10
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Measure
6
(cont.)
(10 to 100) mA
( 0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
0.47 % + 23 µA
0.18 % + 23 µA
0.069 % + 23 µA
0.035 % + 23 µA
0.47 % + 0.24 mA
0.19 % + 0.23 mA
0.092 % + 0.23 mA
0.12 % + 0.23 mA
Agilent 3458A (based
on 2 year specs)
AC Voltage – Generate
4, 6
(1 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.022 % + 4.1 µV
85 µV/V + 4.0 µV
75 µV/V + 4.0 µV
0.018 % + 4.0 µV
0.046 % + 5.0 µV
0.090 % + 10 µV
0.12 % + 20 µV
0.25 % + 20 µV
0.022 % + 4.1 µV
85 µV/V + 4.0 µV
75 µV/V + 4.0 µV
0.018 % + 4.0 µV
0.046 % + 5.0 µV
0.090 % + 10 µV
0.12 % + 20 µV
0.25 % + 20 µV
0.022 % + 12 µV
85 µV/V + 7.2 µV
75 µV/V + 7.0 µV
0.018 % + 7.0 µV
0.042 % + 17 µV
0.075 % + 20 µV
0.12 % + 25 µV
0.25 % + 45 µV
0.022 % + 41 µV
80 µV/V + 17 µV
40 µV/V + 8.0 µV
70 µV/V + 10 µV
0.011 % + 30 µV
0.034 % + 81 µV
0.090 % + 0.20 mV
0.15 % + 0.30 mV
Fluke 5730A
(based on 90 day
specs) | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2611.01) 07/28/2025 Page 7 of 10
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Generate
4, 6
(cont.)
(2.2 to 22) V
(22 to 220) V
For the 1100 V Range:
(220 to 250) V
(220 to 1100) V
(220 to 750) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
0.022 % + 0.41 mV
80 µV/V + 0.17 mV
40 µV/V + 51 µV
70 µV/V + 0.10 mV
95 µV/V + 0.20 mV
0.026 % + 0.60 mV
0.090 % + 2.0 mV
0.13 % + 3.2 mV
0.022 % + 4.0 mV
80 µV/V + 1.7 mV
47 µV/V + 0.60 mV
75 µV/V + 1.0 mV
0.013 % + 2.5 mV
0.080 % + 16 mV
0.42 % + 40 mV
0.70 % + 80 mV
0.026 % + 16 mV
80 µV/V + 4.1 mV
0.013 % + 6.0 mV
0.036 % + 11 mV
0.036 % + 11 mV
0.13 % + 45 mV
Fluke 5730A
(based on 90 day
specs)
Fluke 5730A/5725A
(based on 90 day
specs)
AC Voltage – Measure5, 6
(1 to 10) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
83 µV/V + 0.46 mV
83 µV/V + 0.23 mV
0.017 % + 0.23 mV
Agilent 3458A (based
on 2 year specs) | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2611.01) 07/28/2025 Page 8 of 10
Parameter/Equipment
Frequency
CMC2 (±)
Comments
4 Terminal Parallel
Capacitance – Generate3
1 pF
10 pF
100 pF
1000 pF
10 nF
100 nF
1 MHz
10 MHz
100 kHz
1 MHz
10 MHz
10 kHz
100 kHz
1 MHz
10 MHz
1 kHz
10 kHz
100 kHz
1 MHz
10 MHz
1 kHz
10 kHz
100 kHz
1 kHz
10 kHz
1.4 fF
7.9 fF
4.4 fF
5.4 fF
29 fF
67 fF
37 fF
20 fF
0.1 pF
9.2 pF
0.36 pF
0.19 pF
0.25 pF
2.3 pF
15 pF
2.1 pF
2.6 pF
35 pF
30 pF
Set of standard
capacitors from 1 pF
to 100 nF
4 Terminal Parallel
Conductance – Generate3
1 pF, (1 to 17) nS
1 pF, (5 to 200) nS
10 pF, (0.1 to 1.4) nS
10 pF, (2.2 to 17) nS
10 pF, (2 to 3) µS
100 pF, (1 to 22) nS
100 pF, (7.1 to 19.2) nS
100 pF, (0.26 to 122) nS
100 pF, (13 to 30) µS
1000 pF, (1.4 to 2.8) nS
1000 pF, (8 to 31) nS
1000 pF, (122 to 535) nS
1000 pF, 1.7 nS to 14.2 µS
1000 pF, (68 to 695) nS
10 nF, (0.07 to 9.6) nS
10 nF, (1.4 to 40) nS
10 nF, (67 to 324) nS
100 nF, (34.4 to 68) nS
100 nF, (111 to 404) nS
1 MHz
10 MHz
100 kHz
1 MHz
10 MHz
10 kHz
100 kHz
1 MHz
10 MHz
1 kHz
10 kHz
100 kHz
1 MHz
10 MHz
1 kHz
10 kHz
100 kHz
1 kHz
10 kHz
4.2 nS
48 nS
1.3 nS
2.4 nS
61 nS
2.5 nS
2.4 nS
16 nS
1.1 µS
41 nS
4.3 nS
24 nS
0.5 µS
44 µS
38 nS
37 nS
0.35 µS
0.70 µS
0.42 µS
Keithley 4210-CVU
CAL-KIT
Keithley 4210-CVU
CAL-KIT | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2611.01) 07/28/2025 Page 9 of 10
Parameter/Equipment
Frequency
CMC2, 7 (±)
Comments
Pulse Characterization –
Measure, Fixed Points
3
Overshoot
Preshoot
Pulse Width
Settling Time
RMS Jitter
Slew Rate
0.5 V
2 V
5 V
20 V
20 mV
80 mV
500 ns
0 s
0 s
0.5 V/ns
0.2 V/ns
1.4 %
0.87 %
0.29 %
0.13 %
8.5 mV
35 mV
0.44 ns
2.7 ns
20 ps
0.089 V/ns
0.0083 V/ns
Digital oscilloscope
II. Time & Frequency
Parameter/Equipment
Frequency
CMC
2 (±)
Comments
Frequency – Measuring
Equipment
4, 6
Fixed Point
(1 to 10) Hz
10 Hz to 1 kHz
1 kHz to 20 MHz
10 MHz
6.7 μHz/Hz
5.8 μHz/Hz
5.8 μHz/Hz
49 mHz
Agilent 33220A /
Spectrum TM4
GPS oscillator
Spectrum TM4
______________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2611.01) 07/28/2025 Page 10 of 10
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This capability is suitable for th e calibration of the devices intended to measure the stated measurand in
the ranges indicated. CMC is expressed as either a specific value that covers the full range or as a fraction
of the reading plus floor specification.
5 This capability is suitable for the calibration of th e devices intended to generate the measurand in the
ranges indicated. CMC is expressed as either a specific value that covers the full range or as a combination
of the fraction of the reading /output plus a range specification.
6 CMC is [µX/X of Reading] + offset (where listed) for the ranges indicated in the Parameter/Equipment
column of table, where “X” equals V, Ω, A or Hz.
7 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated. | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
KEITHLEY INSTRUMENTS GERMANY
Germering, GERMANY
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General
requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of
R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical
competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 28th day of July 2025.
__ _____________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2611.01
Valid to September 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.