SERVICIOS DE APOYO A LA INVESTIGACIÓN DE LA UNIVERSIDAD DE A CORUÑA
Unidad de Calidad/Servicios de Apoyo a Investigación. Edificio Servicios Centrales de Investigación. Campus Elviña., 15071, Coruña, Spain
Visit website- Accredited standards
- 8
- ENAC certificates
- 3
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ENAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 27888Water quality - Determination of electrical conductivity
EPA 7473
ISO 9277Determination of the specific surface area of solids by gas adsorption - BET method
ISO 10523Water quality - Determination of pH
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 15923-1Water quality - Determination of selected parameters by discrete analysis systems - Part 1: Ammonium, nitrate, nitrite, chloride, orthophosphate, sulfate and silicate with photometric detection
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
UNE-EN ISO 10523; UNE-EN 27888; UNE-EN 872; SM 5210 D; ISO 15923-1; ISO 15705; UNE-EN ISO 17294-2
Reglamento (UE) nº 2017/644 Anexo IV; Reglamento (CE) nº 152/2009 y sus posteriores modificaciones Anexo V.B Capítulo III; EPA Method 7473 (SW-846)
ISO 9277
UNE-EN ISO 17294-2; P-SAI-UEPM-001
Read from the scope as published by ENAC. Register refreshed 2026-10-10.
Scope as published by ENAC
5 lines
ISO/IEC 17025
Active725/LE1402
Accredited scope, certificate 725/LE1402
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNE-EN ISO/IEC 17025:2017; Reglamento (UE) nº 2017/644, Anexo III; Reglamento (CE) 152/2009, Anexo V.B Capítulo II; Reglamento (CE) 278/2012 | Forrajes, cereales y piensos; Carnes y derivados cárnicos; Pescados, moluscos, crustáceos y cefalópodos; Aceites, grasas y mantequillas; Huevos y derivados | - |
| 2 | Reglamento (UE) nº 2017/644 Anexo IV; Reglamento (CE) nº 152/2009 y sus posteriores modificaciones Anexo V.B Capítulo III; EPA Method 7473 (SW-846) | Forrajes, cereales y piensos; Carnes y derivados cárnicos; Pescados, moluscos, crustáceos y cefalópodos; Aceites, grasas y mantequillas; Huevos y derivados | 0.18 to µg/kg |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active725/LE1798
Accredited scope, certificate 725/LE1798
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNE-EN ISO 10523; UNE-EN 27888; UNE-EN 872; SM 5210 D; ISO 15923-1; ISO 15705; UNE-EN ISO 17294-2 | Aguas continentales no tratadas | - |
| 2 | UNE-EN ISO 17294-2; P-SAI-UEPM-001 | Aguas residuales | 0.5 to µg/l |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active725/LE2159
Accredited scope, certificate 725/LE2159
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 9277 | microsilica | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Unidad de Calidad/Servicios de Apoyo a Investigación. Edificio Servicios Centrales de Investigación. Campus Elviña., Coruña, 15071, ES
43.15399, -8.58051
Open in MapsLabs with overlapping accredited scope in Spain
- TENTAMUS CONYCAL, S.L. (Unipersonal)Oviedo · ~222 kmENACShares 1 accredited test methodISO 15923-1
- URIKERZamudio · ~463 kmENACShares 1 accredited test methodISO 15923-1
- LABORATORIOS MICROALBollullos de la Mitación · ~679 kmENACShares 1 accredited test methodISO 15923-1
- AGROLAB MEDIOAMBIENTETarragona · ~841 kmENACShares 1 accredited test methodISO 15923-1
- LABORATORIO ECHEVARNESant Cugat del Vallès · ~894 kmENACShares 1 accredited test methodISO 15923-1
Accreditation data refreshed from the ENAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.