Northrop Grumman Defense Systems
999 South Oyster Bay Road, Suite 220, 11714, Bethpage, NY, United States
- Scope lines
- 9
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 9 scope lines.
A2LA certificate 1949.02 · 9 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1949.02) 08/28/2024 Page 1 of 8
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
NORTHROP GRUMMAN DEFENSE SYSTEMS
999 South Oyster Bay Road, Suite 220
Bethpage, NY 11714
Elizabeth Luchsinger Phone: (516) 346-7555
CALIBRATION
Valid To: July 31, 2026 Certificate Number: 1949.02
In recognition of the successful completion of the A2 LA evaluation process, (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements) accreditation is granted to
this laboratory to perform the following calibrations
1, 5:
I. Dimensional
Parameter/Equipment
Range
CMC
2 (±)
Comments
Gage Blocks
Up to 1 in
Up to 2 in
Up to 3 in
Up to 5 in
Up to 6 in
Up to 7 in
Up to 8 in
Up to 10 in
Up to 12 in
Up to 16 in
Up to 20 in
5.0 µin
10 µin
11 µin
16 µin
22 µin
21 µin
21 µin
27 µin
31 µin
38 µin
44 µin
Mechanical comparison
with reference blocks
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC
2, 3, 6 (±)
Comments
Resistance – Generate,
Fixed Points
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
0.013 %
0.012 %
34 µΩ/Ω
31 µΩ/Ω
14 µΩ/Ω
Fluke 5730A | to 1 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1949.02) 08/28/2024 Page 2 of 8
Parameter/Equipment
Range
CMC2, 3, 6 (±)
Comments
Resistance – Generate,
Fixed Points (cont)
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
1 Ω
10 kΩ
14 µΩ/Ω
13 µΩ/Ω
13 µΩ/Ω
13 µΩ/Ω
12 µΩ/Ω
16 µΩ/Ω
15 µΩ/Ω
24 µΩ/Ω
25 µΩ/Ω
95 µΩ/Ω
87 µΩ/
Ω
0.014 %
9.4 µΩ/Ω
5.3 µΩ/Ω
Fluke 5730A
Fluke 742A-1
Fluke 742A-10K
Resistance – Measure
(0 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
(0.2 to 2) kΩ
(2 to 20) kΩ
(20 to 200) kΩ
(0.2 to 2) MΩ
(2 to 20) MΩ
(20 to 200) MΩ
(0.2 to 2) GΩ
27 µΩ/Ω + 5.8 µΩ
16 µΩ/Ω + 21 µΩ
13 µΩ/Ω + 70 µΩ
15 µΩ/Ω + 700 µΩ
13 µΩ/Ω + 7 mΩ
13 µΩ/Ω + 70 mΩ
18 µΩ/Ω + 1.4 Ω
35 µΩ/Ω + 140 Ω
0.019 % + 14 kΩ
0.18 % + 1.4 MΩ
Fluke 8508A-01
DC Voltage – Generate
Fixed Point
(0 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(22 to 220) V
(220 to 1000) V
10 V
15 µV/V + 0.58 µV
5.2 µV/V + 0.93 µV
3.9 µV/V + 5.8 µV
5.9 µV/V + 58 µV
8.4 µV/V + 580 µV
3.6 µV/V
Fluke 5730A
Fluke 732A
DC Voltage – Measure
(0 to 200) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
11 µV/V + 0.14 µV
6.3 µV/V + 0.58 µV
5.5 µV/V + 5.8 µV
8.4 µV/V + 58 µV
8.4 µV/V + 700 µV
Fluke 8508A-01
DC Current – Generate
(0 to 220) µA
220 µA to 2.2 mA
(2.2 to 22) mA
50 µA/A + 8.1 nA
44 µA/A + 9.3 nA
43 µA/A + 58 nA
Fluke 5730A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1949.02) 08/28/2024 Page 3 of 8
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Current – Generate
(cont)
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
64 µA/A + 0.93 µA
0.013 % + 18 µA
0.041 % + 560 µA
Fluke 5730A
Fluke 5725A
DC Current – Measure
(0 to 200) µA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
21 µA/A + 0.47 nA
22 µA/A + 4.7 nA
22 µA/A + 47 nA
71 µA/A + 930 nA
0.026 % + 19 µA
0.059 % + 470 µA
Fluke 8508A-01
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
Up to 2.2 mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
0.12 % + 5.8 µV
0.16 % + 5.8 µV
0.17 % + 7 µV
0.25 % + 14 µV
0.31 % + 29 µV
0.65 % + 29 µV
0.035 % + 5.8 µV
0.016 % + 5.8 µV
0.015 % + 5.8 µV
0.031 % + 5.8 µV
0.066 % + 7.0 µV
0.15 % + 14 µV
0.19 % + 29 µV
0.41 % + 29 µV
0.032 % + 18 µV
0.014 % + 9.3 µV
0.013 % + 9.3 µV
0.029 % + 9.3 µV
0.064 % + 23 µV
0.11 % + 29 µV
0.18 % + 35 µV
0.36 % + 70 µV
0.032 % + 58 µV
0.013 % + 23 µV
Fluke 5730A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1949.02) 08/28/2024 Page 4 of 8
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
(cont)
220 mV to 2.2 V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
50 Hz to 1 kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
0.0064 % + 12 µV
0.012 % + 14 µV
0.015 % + 47 µV
0.050 % + 120 µV
0.13 % + 290 µV
0.23 % + 700 µV
0.034 % + 580 µV
0.014 % + 230 µV
0.0077 % + 81 µV
0.011 % + 140 µV
0.015 % + 290 µV
0.038 % + 930 µV
0.13 % + 2.9 mV
0.21 % + 4.7 mV
0.033 % + 5.8 mV
0.013 % + 2.3 mV
0.0080 % + 810 µV
0.012 % + 1.4 mV
0.021 % + 3.5 mV
0.011 % + 4.7 mV
0.0098 % + 4.7 mV
0.015 % + 7.0 mV
0.043 % + 13 mV
Fluke 5730A
Fluke 5730A
Fluke 5725A
AC Voltage – Measure
Up to 200 mV
(0.2 to 2) V
(10 to 40) Hz
(40 to 100) Hz
100 to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
0.02 % + 5.8 µV
0.017 % + 5.8 µV
0.017 % + 2.8 µV
0.021 % + 5.8 µV
0.048 % + 12 µV
0.10 % + 28 µV
0.017 % + 28 µV
0.014 % + 28 µV
0.011 % + 28 µV
0.017 % + 28 µV
0.032 % + 58 µV
0.077 % + 280 µV
0.077 % + 280 µV
1.2 % + 28 mV
Fluke 8508A-01 | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1949.02) 08/28/2024 Page 5 of 8
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure
(cont)
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
0.017 % + 280 µV
0.015 % + 280 µV
0.012 % + 280 µV
0.018 % + 280 µV
0.032 % + 580 µV
0.076 % + 2.8 mV
1.2 % + 280 mV
0.017 % + 2.8 mV
0.014 % + 2.8 mV
0.012 % + 2.8 mV
0.017 % + 2.8 mV
0.031 % + 28 mV
0.076 % + 28 mV
0.35 % + 280 mV
0.040 % + 29 mV
0.055 % + 58 mV
0.22 % + 290 mV
Fluke 8508A-01
AC Current – Generate
Up to 220 µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.035 % + 23 nA
0.023 % + 14 nA
0.017 % + 12 nA
0.041 % + 18 nA
0.14 % + 93 nA
0.034 % + 58 nA
0.022 % + 47 nA
0.017 % + 47 nA
0.027 % + 150 nA
0.13 % + 930 nA
0.036 % + 580 nA
0.024 % + 470 nA
0.03 % + 810 nA
0.13 % + 7.0 µA
0.039 % + 5.8 µA
0.023 % + 4.7 µA
0.017 % + 3.5 µA
0.028 % + 4.7 µA
0.14 % + 14 µA
Fluke 5730A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1949.02) 08/28/2024 Page 6 of 8
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Generate
(cont)
220 mA to 2.2 A
(2.2 to 11) A
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.036 % + 47 µA
0.058 % + 120 µA
0.82 % + 230 µA
0.048 % + 200 µA
0.10 % + 440 µA
0.39 % + 870 µA
Fluke 5730A
Fluke 5725A
AC Current – Measure
Up to 200 µA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 5 kHz
(5 to 10) kHz
10 Hz to 1 kHz
(1 to 10) kHz
10 Hz to 1 kHz
(1 to 10) kHz
0.078 % + 28 nA
0.045 % + 0.28 µA
0.047 % + 2.8 µA
0.05 % + 28 µA
0.14 % + 28 µA
0.085 % + 280 µA
0.14 % + 280 µA
0.11 % + 2.8 mA
0.33 % + 2.8 mA
Fluke 8508A-01
III. Mechanical
Parameter/Equipment
Range
CMC
2, 4, 6 (±)
Comments
Force, Tension &
Compression – Measure
Up to 1000 lbf
(1000 to 10 000) lbf
0.06 % of F.S.
0.06 % of F.S.
Comparison to gold
load cells
Gage Pressure
–
Measure & Generate
Gas
(10 to 93) psig
(93 to 1000) psig
0.032 %
0.024 %
Pressure calibrator,
Ruska 7250XI | ||
| 7 | - | GasShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1949.02) 08/28/2024 Page 7 of 8
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Gage Pressure
–
Measure & Generate
(cont)
Gas
(0 to 68) inꞏHg at 0°C
Up to 8.7 inꞏH
2O at 4°C
(8.7 to 100) inꞏH2O at 4°C
0.008 inꞏHg at 0 °C
0.05 % of rdg at 4°C
0.016 % of rdg at 4°C
Air Data test set
Ruska 7750I
Ruska 7250LP
Mass – Metric, Fixed
Points – Measure
1 g
2 g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2 kg
5 kg
10 kg
20 kg
0.048 mg
0.041 mg
0.041 mg
0.091 mg
0.090 mg
0.15 mg
0.3 mg
0.59 mg
1.5 mg
3.0 mg
6.3 mg
27 mg
36 mg
64 mg
Mettler balances,
direct comparison to
Class 1 weights
Mass – Avoirdupois,
Fixed Points
0.89 g (1/32 oz)
1.77 g (1/16 oz)
3.54 g (1/8 oz)
7.09 g (1/4 oz)
14.17 g (1/2 oz)
28.35 g (1 oz)
56.7 g (2 oz)
113.4 g (4 oz)
226.8 g (8 oz)
453.6 g (1 lb)
907.2 g (2 lb)
1.36 kg (3 lb)
2.27 kg (5 lb)
4.54 kg (10 lb)
9.07 kg (20 lb)
13.61 kg (30 lb)
22.68 kg (50 lb)
0.036 mg
0.041 mg
0.041 mg
0.062 mg
0.067 mg
0.089 mg
0.17 mg
0.34 mg
0.71 mg
1.3 mg
2.7 mg
4.7 mg
24 mg
26 mg
35 mg
69 mg
75 mg
Mettler balances,
direct comparison to
Class 1 weights
___________________________________________________________
1
This laboratory is not normally available for commercial calibration service. | See scope document |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1949.02) 08/28/2024 Page 8 of 8
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The stated measured values are determined usi ng the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
4 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated. | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
NORTHROP GRUMMAN DEFENSE SYSTEMS
Bethpage, NY
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements
for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration
Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 28th day of August 2024.
__ _____________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1949.02
Valid to July 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.