United States

Northrop Grumman Defense Systems

999 South Oyster Bay Road, Suite 220, 11714, Bethpage, NY, United States

A2LA 1949.02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
9
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 9 scope lines.

A2LA certificate 1949.02 · 9 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1949.02) 08/28/2024 Page 1 of 8 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 NORTHROP GRUMMAN DEFENSE SYSTEMS 999 South Oyster Bay Road, Suite 220 Bethpage, NY 11714 Elizabeth Luchsinger Phone: (516) 346-7555 CALIBRATION Valid To: July 31, 2026 Certificate Number: 1949.02 In recognition of the successful completion of the A2 LA evaluation process, (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements) accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter/Equipment Range CMC 2 (±) Comments Gage Blocks Up to 1 in Up to 2 in Up to 3 in Up to 5 in Up to 6 in Up to 7 in Up to 8 in Up to 10 in Up to 12 in Up to 16 in Up to 20 in 5.0 µin 10 µin 11 µin 16 µin 22 µin 21 µin 21 µin 27 µin 31 µin 38 µin 44 µin Mechanical comparison with reference blocks II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2, 3, 6 (±) Comments Resistance – Generate, Fixed Points 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 0.013 % 0.012 % 34 µΩ/Ω 31 µΩ/Ω 14 µΩ/Ω Fluke 5730A
to 1 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1949.02) 08/28/2024 Page 2 of 8 Parameter/Equipment Range CMC2, 3, 6 (±) Comments Resistance – Generate, Fixed Points (cont) 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 1 Ω 10 kΩ 14 µΩ/Ω 13 µΩ/Ω 13 µΩ/Ω 13 µΩ/Ω 12 µΩ/Ω 16 µΩ/Ω 15 µΩ/Ω 24 µΩ/Ω 25 µΩ/Ω 95 µΩ/Ω 87 µΩ/ Ω 0.014 % 9.4 µΩ/Ω 5.3 µΩ/Ω Fluke 5730A Fluke 742A-1 Fluke 742A-10K Resistance – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω (0.2 to 2) kΩ (2 to 20) kΩ (20 to 200) kΩ (0.2 to 2) MΩ (2 to 20) MΩ (20 to 200) MΩ (0.2 to 2) GΩ 27 µΩ/Ω + 5.8 µΩ 16 µΩ/Ω + 21 µΩ 13 µΩ/Ω + 70 µΩ 15 µΩ/Ω + 700 µΩ 13 µΩ/Ω + 7 mΩ 13 µΩ/Ω + 70 mΩ 18 µΩ/Ω + 1.4 Ω 35 µΩ/Ω + 140 Ω 0.019 % + 14 kΩ 0.18 % + 1.4 MΩ Fluke 8508A-01 DC Voltage – Generate Fixed Point (0 to 220) mV 220 mV to 2.2 V (2.2 to 22) V (22 to 220) V (220 to 1000) V 10 V 15 µV/V + 0.58 µV 5.2 µV/V + 0.93 µV 3.9 µV/V + 5.8 µV 5.9 µV/V + 58 µV 8.4 µV/V + 580 µV 3.6 µV/V Fluke 5730A Fluke 732A DC Voltage – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V 11 µV/V + 0.14 µV 6.3 µV/V + 0.58 µV 5.5 µV/V + 5.8 µV 8.4 µV/V + 58 µV 8.4 µV/V + 700 µV Fluke 8508A-01 DC Current – Generate (0 to 220) µA 220 µA to 2.2 mA (2.2 to 22) mA 50 µA/A + 8.1 nA 44 µA/A + 9.3 nA 43 µA/A + 58 nA Fluke 5730A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1949.02) 08/28/2024 Page 3 of 8 Parameter/Equipment Range CMC2, 3 (±) Comments DC Current – Generate (cont) (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A 64 µA/A + 0.93 µA 0.013 % + 18 µA 0.041 % + 560 µA Fluke 5730A Fluke 5725A DC Current – Measure (0 to 200) µA (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A 21 µA/A + 0.47 nA 22 µA/A + 4.7 nA 22 µA/A + 47 nA 71 µA/A + 930 nA 0.026 % + 19 µA 0.059 % + 470 µA Fluke 8508A-01 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate Up to 2.2 mV (2.2 to 22) mV (22 to 220) mV 220 mV to 2.2 V 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 0.12 % + 5.8 µV 0.16 % + 5.8 µV 0.17 % + 7 µV 0.25 % + 14 µV 0.31 % + 29 µV 0.65 % + 29 µV 0.035 % + 5.8 µV 0.016 % + 5.8 µV 0.015 % + 5.8 µV 0.031 % + 5.8 µV 0.066 % + 7.0 µV 0.15 % + 14 µV 0.19 % + 29 µV 0.41 % + 29 µV 0.032 % + 18 µV 0.014 % + 9.3 µV 0.013 % + 9.3 µV 0.029 % + 9.3 µV 0.064 % + 23 µV 0.11 % + 29 µV 0.18 % + 35 µV 0.36 % + 70 µV 0.032 % + 58 µV 0.013 % + 23 µV Fluke 5730A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1949.02) 08/28/2024 Page 4 of 8 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (cont) 220 mV to 2.2 V (2.2 to 22) V (22 to 220) V (220 to 1100) V 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 50 Hz to 1 kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz 0.0064 % + 12 µV 0.012 % + 14 µV 0.015 % + 47 µV 0.050 % + 120 µV 0.13 % + 290 µV 0.23 % + 700 µV 0.034 % + 580 µV 0.014 % + 230 µV 0.0077 % + 81 µV 0.011 % + 140 µV 0.015 % + 290 µV 0.038 % + 930 µV 0.13 % + 2.9 mV 0.21 % + 4.7 mV 0.033 % + 5.8 mV 0.013 % + 2.3 mV 0.0080 % + 810 µV 0.012 % + 1.4 mV 0.021 % + 3.5 mV 0.011 % + 4.7 mV 0.0098 % + 4.7 mV 0.015 % + 7.0 mV 0.043 % + 13 mV Fluke 5730A Fluke 5730A Fluke 5725A AC Voltage – Measure Up to 200 mV (0.2 to 2) V (10 to 40) Hz (40 to 100) Hz 100 to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 0.02 % + 5.8 µV 0.017 % + 5.8 µV 0.017 % + 2.8 µV 0.021 % + 5.8 µV 0.048 % + 12 µV 0.10 % + 28 µV 0.017 % + 28 µV 0.014 % + 28 µV 0.011 % + 28 µV 0.017 % + 28 µV 0.032 % + 58 µV 0.077 % + 280 µV 0.077 % + 280 µV 1.2 % + 28 mV Fluke 8508A-01
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1949.02) 08/28/2024 Page 5 of 8 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Measure (cont) (2 to 20) V (20 to 200) V (200 to 1000) V (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 0.017 % + 280 µV 0.015 % + 280 µV 0.012 % + 280 µV 0.018 % + 280 µV 0.032 % + 580 µV 0.076 % + 2.8 mV 1.2 % + 280 mV 0.017 % + 2.8 mV 0.014 % + 2.8 mV 0.012 % + 2.8 mV 0.017 % + 2.8 mV 0.031 % + 28 mV 0.076 % + 28 mV 0.35 % + 280 mV 0.040 % + 29 mV 0.055 % + 58 mV 0.22 % + 290 mV Fluke 8508A-01 AC Current – Generate Up to 220 µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.035 % + 23 nA 0.023 % + 14 nA 0.017 % + 12 nA 0.041 % + 18 nA 0.14 % + 93 nA 0.034 % + 58 nA 0.022 % + 47 nA 0.017 % + 47 nA 0.027 % + 150 nA 0.13 % + 930 nA 0.036 % + 580 nA 0.024 % + 470 nA 0.03 % + 810 nA 0.13 % + 7.0 µA 0.039 % + 5.8 µA 0.023 % + 4.7 µA 0.017 % + 3.5 µA 0.028 % + 4.7 µA 0.14 % + 14 µA Fluke 5730A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1949.02) 08/28/2024 Page 6 of 8 Parameter/Range Frequency CMC2, 3 (±) Comments AC Current – Generate (cont) 220 mA to 2.2 A (2.2 to 11) A 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.036 % + 47 µA 0.058 % + 120 µA 0.82 % + 230 µA 0.048 % + 200 µA 0.10 % + 440 µA 0.39 % + 870 µA Fluke 5730A Fluke 5725A AC Current – Measure Up to 200 µA (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 5 kHz (5 to 10) kHz 10 Hz to 1 kHz (1 to 10) kHz 10 Hz to 1 kHz (1 to 10) kHz 0.078 % + 28 nA 0.045 % + 0.28 µA 0.047 % + 2.8 µA 0.05 % + 28 µA 0.14 % + 28 µA 0.085 % + 280 µA 0.14 % + 280 µA 0.11 % + 2.8 mA 0.33 % + 2.8 mA Fluke 8508A-01 III. Mechanical Parameter/Equipment Range CMC 2, 4, 6 (±) Comments Force, Tension & Compression – Measure Up to 1000 lbf (1000 to 10 000) lbf 0.06 % of F.S. 0.06 % of F.S. Comparison to gold load cells Gage Pressure – Measure & Generate Gas (10 to 93) psig (93 to 1000) psig 0.032 % 0.024 % Pressure calibrator, Ruska 7250XI
7-Gas
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1949.02) 08/28/2024 Page 7 of 8 Parameter/Equipment Range CMC2, 4 (±) Comments Gage Pressure – Measure & Generate (cont) Gas (0 to 68) inꞏHg at 0°C Up to 8.7 inꞏH 2O at 4°C (8.7 to 100) inꞏH2O at 4°C 0.008 inꞏHg at 0 °C 0.05 % of rdg at 4°C 0.016 % of rdg at 4°C Air Data test set Ruska 7750I Ruska 7250LP Mass – Metric, Fixed Points – Measure 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 20 kg 0.048 mg 0.041 mg 0.041 mg 0.091 mg 0.090 mg 0.15 mg 0.3 mg 0.59 mg 1.5 mg 3.0 mg 6.3 mg 27 mg 36 mg 64 mg Mettler balances, direct comparison to Class 1 weights Mass – Avoirdupois, Fixed Points 0.89 g (1/32 oz) 1.77 g (1/16 oz) 3.54 g (1/8 oz) 7.09 g (1/4 oz) 14.17 g (1/2 oz) 28.35 g (1 oz) 56.7 g (2 oz) 113.4 g (4 oz) 226.8 g (8 oz) 453.6 g (1 lb) 907.2 g (2 lb) 1.36 kg (3 lb) 2.27 kg (5 lb) 4.54 kg (10 lb) 9.07 kg (20 lb) 13.61 kg (30 lb) 22.68 kg (50 lb) 0.036 mg 0.041 mg 0.041 mg 0.062 mg 0.067 mg 0.089 mg 0.17 mg 0.34 mg 0.71 mg 1.3 mg 2.7 mg 4.7 mg 24 mg 26 mg 35 mg 69 mg 75 mg Mettler balances, direct comparison to Class 1 weights ___________________________________________________________ 1 This laboratory is not normally available for commercial calibration service.
See scope document
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1949.02) 08/28/2024 Page 8 of 8 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 4 The type of instrument or material being calib rated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated.
9

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited NORTHROP GRUMMAN DEFENSE SYSTEMS Bethpage, NY for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 28th day of August 2024. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1949.02 Valid to July 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

999 South Oyster Bay Road, Suite 220, Bethpage, NY, 11714, US

40.75048, -73.48920

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.