Accredited standards
5
SWEDAC certificate
1
Site in our directory
1
SWEDAC accredited scope

What this lab is accredited for

Our reading of the SWEDAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 5 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 3452-1
ISO 5817Welding - Fusion-welded joints in steel, nickel, titanium and their alloys (beam welding excluded) - Quality levels for imperfections
ISO 10042Welding - Arc-welded joints in aluminium and its alloys - Quality levels for imperfections
ISO 17637Non-destructive testing of welds - Visual testing of fusion-welded joints
ISO 23277Non-destructive testing of welds - Penetrant testing - Acceptance levels

Read from the scope as published by SWEDAC. Register refreshed 2026-11-15.

Scope as published by SWEDAC

2 lines
SWEDAC

ISO/IEC 17025

Active

A001205-001

View on SWEDAC

Accredited scope, certificate A001205-001

LineMethodMatrixRange
1SS-EN ISO/IEC 17025:2018; SS-EN 3452-1; SS-EN ISO 23277; SS-EN ISO 17637; SS-EN ISO 10042; SS-EN ISO 5817Metal-
2

Extracted from the scope document; tables may not line up. View scope for the original.

Bilaga 1 Beteckning Datum 2024-09-24 2023/1084 Typ av flexibilitet 1 : - Införa ny version av standardmetod och göra redaktionella ändringar i icke-standardiserad metod. 2 : - Införa ny version av standardmetod och göra redaktionella ändringar i icke-standardiserad metod - Införa ny version och modifieringar av icke-standardiserad metod. Förfarandet ska vara likvärdigt - Införa ny parameter/komponent/undersökning - Införa nytt mätområde - Införa nytt material/nya produkter/matriser - Införa ny metod som är likvärdig med metoder som redan finns i ackrediteringsbeslutet Sida 2 (2)

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Kemistvägen 5, Täby, 183 79, SE

59.45030, 18.08275