Registers refreshed 2026-11-08.See refresh dates
Germany

Deutsches Zentrum für Luft- und Raumfahrt e. V. Institut für Raumfahrtsysteme RY, Abteilung Mechanik und Thermalsysteme (MTS) und Avioniksysteme (AVS)

Robert-Hooke-Straße 7, 28359, Bremen, Germany

DAKKS D-PL-11223-02-01DAKKS D-PL-11223-02-02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
4
DAKKS certificates
2
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 4 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)

Certificate says EN 60068-2-6. Probably the same standard; not checked against the EN document.

IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests

Read from the scope as published by DAKKS. Register refreshed 2026-11-06.

Scope as published by DAKKS

8 lines
DAKKS

ISO/IEC 17025

Active

D-PL-11223-02-01

View scope

Accredited scope, certificate D-PL-11223-02-01

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2DIN EN 60068-2-6; DIN EN 60068-2-27; DIN EN 60068-2-64; DIN EN 61373; ECSS-E-ST-10-03C; MIL-STD-810 G; MIL-STD-810 F--
3ECSS -E-ST -10 -03C--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS

ISO/IEC 17025

Active

D-PL-11223-02-02

View scope

Accredited scope, certificate D-PL-11223-02-02

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2ECSS -E-ST -20 -07C Rev. 1; 2022-01-See scope document
3MIL -STD -461 G; 2015-12-See scope document
4CS114; CS118; RE101; RE102; RS101; RS103-0.03 to 40 GHz
5DIN; ECSS; EN; IEC; ISO; MIL-STD--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Robert-Hooke-Straße 7, Bremen, 28359, DE

53.11107, 8.86130

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.