Laboratorium Badawcze PROTEKT Maria Piłat - Trytko
Pustków Osiedle 59, 39-206, Pustków, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Laboratorium Badawcze PROTEKT Maria Piłat - Trytko?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 977Active
Accredited standards
9Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidanceCertificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.
PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
ISO 7243Ergonomics of the thermal environment - Assessment of heat stress using the WBGT (wet bulb globe temperature) index
PN-EN ISO 11079:2008; PN-EN ISO 7730:2006; PN-EN ISO 7243:2018-01/Ap:2019-07
ISO 7730Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
PN-EN ISO 11079:2008; PN-EN ISO 7730:2006; PN-EN ISO 7243:2018-01/Ap:2019-07
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
PN-Z-04508:2022-05+Ap1:2022-08; PN-N-01307:1994; PN-EN ISO 9612:2011; PN-Z-01339:2020-12; PN-83/E-04040.03
ISO 11079Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effects
PN-EN ISO 11079:2008; PN-EN ISO 7730:2006; PN-EN ISO 7243:2018-01/Ap:2019-07
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-04508:2022-05+Ap1:2022-08; PN-N-01307:1994; PN-EN ISO 9612:2011; PN-Z-01339:2020-12; PN-83/E-04040.03
PN-Z-04008-7:2002+Az1:2004Name not checked yet
PN-Z-04008-7:2002+Az1:2004; PN-Z-04507:2022-05+Ap1:2022-08
Scope as published by PCA
5 lines
ISO/IEC 17025
ActiveAB 977
The scope document we hold says it is valid until 2028-11-24.
Accredited scope, certificate AB 977
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | environmental | - | working environment (harmful and nuisance factors – noise, ultrasonic noise, lighting, microclimate, vibrations); working environment (harmful factors – air) | - |
| 2 | environmental | PN-Z-04008-7:2002+Az1:2004; PN-Z-04507:2022-05+Ap1:2022-08 | Ambient air | 0.16 to 17.01 mg/m³ |
| 3 | environmental | PN-Z-04508:2022-05+Ap1:2022-08; PN-N-01307:1994; PN-EN ISO 9612:2011; PN-Z-01339:2020-12; PN-83/E-04040.03 | Ambient air | 0.16 to 5000 mg/m³; dB; lx |
| 4 | environmental | PN-EN ISO 11079:2008; PN-EN ISO 7730:2006; PN-EN ISO 7243:2018-01/Ap:2019-07 | Workplace environment | -30 to 60 °C; %; m/s |
| 5 | environmental | PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011 | Workplace environment | 0.32 to 100 m/s2 |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Ośrodek Badań Podstawowych Projektów i Wdrożeń Ochrony Środowiska i Biotechnologii "OIKOS"Święta Katarzyna · ~95 kmPCAShares 6 accredited methods and materialsEN ISO 11079:2008EN ISO 5349-1:2004PN-N-01307:1994
- Zakład Usług Technicznych "Ekochem" Jolanta MilewskaBiałystok · ~352 kmPCAShares 6 accredited methods and materialsEN ISO 11079:2008EN ISO 5349-1:2004PN-N-01307:1994
- Laboratorium Usługowo-Badawcze "Biochemik"Piła · ~466 kmPCAShares 6 accredited methods and materialsEN ISO 11079:2008EN ISO 5349-1:2004PN-N-01307:1994
- SBB Laboratorium Badań i EkspertyzKatowice · ~177 kmPCAShares 5 accredited methods and materialsEN ISO 5349-1:2004PN-N-01307:1994PN-Z-04008-7:2002+Az1:2004
- GRUPA EKOPROJEKTBielsko-Biała · ~178 kmPCAShares 5 accredited methods and materialsEN ISO 11079:2008EN ISO 5349-1:2004PN-N-01307:1994
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.