Registers refreshed 2026-11-20.See refresh dates
China

Luxottica Tristar(Dongguan) Optical Co.,Ltd

OuDeng Zone, Gao Bu Town, Dong Guan City, Guangdong Province, 523268, People's Republic of China, Guangdong Province, China

A2LA 3387.04ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
9
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 9 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 12472
EN 16128
ISO 8624Ophthalmic optics - Spectacle frames - Measuring system and vocabulary
ISO 12311Personal protective equipment - Test methods for sunglasses and related eyewear+1 national

National versions in the same scope

AS/NZS 1067.2identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

ISO 12312-1Eye and face protection - Sunglasses and related eyewear - Part 1: Sunglasses for general use
ISO 12870Ophthalmic optics - Spectacle frames - Requirements and test methods
ISO 18526-1Eye and face protection - Test methods - Part 1: Geometrical optical properties
ISO 18526-2Eye and face protection - Test methods - Part 2: Physical optical properties
ISO 18526-3Eye and face protection - Test methods - Part 3: Physical and mechanical properties

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

3387.04

The scope document we hold says it was valid until 2026-10-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 3387.04

LineMethodMatrixRange
1ISO 8624; GB/T 38004; ISO 12870; GB/T 14214; ISO 12311eyewear-
2ISO 12311; ISO 18526-1; ISO 18526-2; ISO 18526-3; ISO 12312-1; GB/T 39552.2--
3GB/T 39552.2; GB/T 39552.1; AS/NZS 1067.2; AS/NZS 1067.1; ANSI Z80.3--
4ANSI Z80.3; EN 16128; GB/T 38009; EN 12472--
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited LUXOTTICA QUALITY PERFORMANCE LABORATORY – TRISTAR Guangdong, People’s Republic of China for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 22nd day of August 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3387.04 Valid to October 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.