Registers refreshed 2026-11-20.See refresh dates
United States

Precision Measuring

33250 Groesbeck Highway, P.O. Box 26118, 48026, Fraser, MI, United States

Visit website
A2LA 1768.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 1768.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; R205-to 125 ft
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1768.01) 8/22/2025 Page 2 of 4 Parameter/Equipment Range CMC2, 4 (±) Comments Straightness3 – CMMs, Boring Mills, Lathes, Machining Centers, Layout Machines Up to 400 µin (400 to 60 000) µin Up to 4000 µin (4000 to 60 000) µin (27 + 0.035S + 0.5F 2) µin (27 + 0.01S + 0.5F2) µin (27 + 0.05S + 0.05F 2) µin (120 + 0.025S + 0.05F2) µin Laser with short range optics; up to 10 feet distance Laser with long range optics; 3 to 33 feet distance Squareness3 – CMMs, Boring Mills, Lathes, Machining Centers, Layout Machines Up to 18 in 180 µin Master square and indicator Angle3 – CMMs, Boring Mills, Lathes, Machining Centers, Layout Machines, Electronic Levels, etc. Up to 10° Up to 200 second (0.82 + 0.002B + 0.05M) arcsec 1.8 arcsec Laser interferometer Electronic level Angle – Machine Tools 0 to 360 degrees 0.000 39 degrees Renishaw XR20 (Rotary Axis Calibrator) w/ XL-80 laser interferometer Surface Plate – Overall Flatness Only3 Up to 20 ft × 30 ft (320 + 44D) µin Electronic levels Note: uncertainty is to be no less than the acceptable closure error for the procedure
3-Fixtures; Products; Go-No Go Gages; Inner Diameter; Outer Diameter
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1768.01) 8/22/2025 Page 3 of 4 II. Dimensional Testing/Calibration1 Parameter/Equipment Range CMC2, 4 (±) Comments Length Measurements5, 6, 7 – 1D, 2D and 3D X: Up to 110 in Y: Up to 45 in Z: Up to 54 in X-Y-Z: 29.59 in X: Up to 35 in Y: Up to 59 in Z: Up to 35 in X-Y-Z: 21.70 in X: Up to 120 in Y: Up to 55 in Z: Up to 60 in X-Y-Z: 35.47 in Up to 131 ft hemisphere Up to 3.5 meter (3200 + 1.3L) µin 710 µin (1400 + 2.4L) µin 390 µin (4200 + 1.7L) µin 2500 µin (1000 + 1.9L) µin 0.14 mm (tactile only) Mitutoyo CHN 1612 CMM Ball bar Brown and Sharpe XCel CMM Ball bar DEA – Vento CMM Ball bar Faro laser tracker Hexagon articulating arm CMM, 2D Length Measurements5, 6 (non-contact) X: 300 mm Y: 200 mm (2.9 + 0.01L) µm Vision system Length Measurements5 – Fixtures, Products, Go- No Go Gages, Inner Diameter, Outer Diameter Up to 2 in Up to 8 in (0.061 to 1.0) in (110 + 10L) µin 1200 µin 590 µin Micrometer Caliper Pin gages ___________________________________________ 1 This laboratory offers commercial calibration service, dimensional testing, and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
See scope document
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1768.01) 8/22/2025 Page 4 of 4 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. , resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, for linear measurements; L is the nominal length of the device in inches, except where noted. For straightness and squareness measurements, S is the straightness error in micro-inches; F is the distance the optics travel during test in feet. With angle measurements, B is the measured error in arc-seconds, and M is the distance the optics travel during test in meter s. With flatness measurements, D is the diagonal length of the surface plate. 5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 6 CMC performance is identified as 3D (X-Y-Z) for measurements performed with the Faro Laser Tracker and Hexagon Articulating Arm CMM in the stated machine volume of the X, Y and Z coordinate ranges; or in the case of 2D non-contact measurements, the area of X and Y coordinates. 7 3D (X-Y-Z) length measurement performance is within the stated X, Y and Z coordinate ranges based on ball bar test data. 8 This scope meets A2LA’s P112 Flexible Scope Policy.
5ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

33250 Groesbeck Highway, P.O. Box 26118, Fraser, MI, 48026, US

42.53920, -82.94937

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.