Precision Measuring
33250 Groesbeck Highway, P.O. Box 26118, 48026, Fraser, MI, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 1768.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; R205 | - | to 125 ft |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1768.01) 8/22/2025 Page 2 of 4
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Straightness3 –
CMMs, Boring Mills,
Lathes, Machining
Centers, Layout
Machines
Up to 400 µin
(400 to 60 000) µin
Up to 4000 µin
(4000 to 60 000) µin
(27 + 0.035S + 0.5F
2) µin
(27 + 0.01S + 0.5F2) µin
(27 + 0.05S + 0.05F
2) µin
(120 + 0.025S + 0.05F2) µin
Laser with short
range optics; up to 10
feet distance
Laser with long range
optics; 3 to 33 feet
distance
Squareness3 –
CMMs, Boring Mills,
Lathes, Machining
Centers, Layout
Machines
Up to 18 in
180 µin
Master square and
indicator
Angle3 – CMMs,
Boring Mills, Lathes,
Machining Centers,
Layout Machines,
Electronic Levels, etc.
Up to 10°
Up to 200 second
(0.82 + 0.002B + 0.05M)
arcsec
1.8 arcsec
Laser interferometer
Electronic level
Angle – Machine Tools
0 to 360 degrees
0.000 39 degrees
Renishaw XR20
(Rotary Axis
Calibrator) w/ XL-80
laser interferometer
Surface Plate – Overall
Flatness Only3
Up to 20 ft × 30 ft
(320 + 44D) µin
Electronic levels
Note: uncertainty is
to be no less than the
acceptable closure
error for the
procedure | ||
| 3 | - | Fixtures; Products; Go-No Go Gages; Inner Diameter; Outer DiameterShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1768.01) 8/22/2025 Page 3 of 4
II. Dimensional Testing/Calibration1
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Length Measurements5, 6,
7 – 1D, 2D and 3D
X: Up to 110 in
Y: Up to 45 in
Z: Up to 54 in
X-Y-Z: 29.59 in
X: Up to 35 in
Y: Up to 59 in
Z: Up to 35 in
X-Y-Z: 21.70 in
X: Up to 120 in
Y: Up to 55 in
Z: Up to 60 in
X-Y-Z: 35.47 in
Up to 131 ft hemisphere
Up to 3.5 meter
(3200 + 1.3L) µin
710 µin
(1400 + 2.4L) µin
390 µin
(4200 + 1.7L) µin
2500 µin
(1000 + 1.9L) µin
0.14 mm (tactile
only)
Mitutoyo CHN 1612
CMM
Ball bar
Brown and Sharpe
XCel CMM
Ball bar
DEA – Vento CMM
Ball bar
Faro laser tracker
Hexagon articulating
arm CMM,
2D Length
Measurements5, 6
(non-contact)
X: 300 mm
Y: 200 mm
(2.9 + 0.01L) µm
Vision system
Length Measurements5 –
Fixtures, Products, Go-
No Go Gages, Inner
Diameter, Outer
Diameter
Up to 2 in
Up to 8 in
(0.061 to 1.0) in
(110 + 10L) µin
1200 µin
590 µin
Micrometer
Caliper
Pin gages
___________________________________________
1 This laboratory offers commercial calibration service, dimensional testing, and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to
influences from the circumstances of the specific calibration. | See scope document |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1768.01) 8/22/2025 Page 4 of 4
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. , resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, for linear measurements; L is the nominal length of the device in inches, except
where noted. For straightness and squareness measurements, S is the straightness error in micro-inches; F
is the distance the optics travel during test in feet. With angle measurements, B is the measured error in
arc-seconds, and M is the distance the optics travel during test in meter s. With flatness measurements, D
is the diagonal length of the surface plate.
5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration.
6 CMC performance is identified as 3D (X-Y-Z) for measurements performed with the Faro Laser Tracker
and Hexagon Articulating Arm CMM in the stated machine volume of the X, Y and Z coordinate ranges;
or in the case of 2D non-contact measurements, the area of X and Y coordinates.
7 3D (X-Y-Z) length measurement performance is within the stated X, Y and Z coordinate ranges based on
ball bar test data.
8 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 5 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.