Oneida Research Services
4201 Pottsville Pike, Suite 420, 19605, Reading, PA, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Oneida Research Services?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 2930.01Active
Certificates and scope
1ISO/IEC 17025
Active2930.01
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 2930.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | mechanical | JESD22-A108; MIL-STD-202 Method 108; MIL-STD-750 Methods 1026; MIL-STD-750 Methods 1038; MIL-STD-750 Methods 1039; MIL-STD-750 Methods 1040; MIL-STD-750 Methods 1048; MIL-STD-883 Methods 1005; MIL-STD-883 Methods 1015; MIL-STD-883 Methods 1016; AEC-Q100; AEC-Q200; GR-468-CORE (3.3.2.1); JESD22-A103 Cond A-G; MIL-STD-202 Method 108; MIL-STD-750 Method 1031; MIL-STD-883 Method 1008; GR-468-CORE (3.3.2.1); JESD22-A119; JESD22-A119, Cond A-C; GR-468-CORE; JESD22-A104; MIL-STD-750 Methods 1051; MIL-STD-750 Methods 1055; MIL-STD-883 Method 1010; JESD22-A105; MIL-STD-883 Method 1007 | Medical devices | -65 to 300 °C |
| 2 | materials | AEC-Q101; JESD22-A108; MIL-STD-750 Method 1042; MIL-STD-883 Method 1005; JESD22-A106; MIL-STD-202 Method 107; MIL-STD-750 Method 1056; MIL-STD-883 Method 1011; AEC-Q100-008; MIL-STD-750 Method 1036; MIL-STD-883 Methods 1006, 1005; GR-468-CORE; MIL-STD-202 Method 103; JESD22-A100; MIL-STD-202 Method 106; MIL-STD-750 Method 1021; MIL-STD-810 Method 507; MIL-STD-883 Method 1004; JESD22-A101; MIL-STD-202 Method 103; JESD22-A100; MIL-STD-750 Method 1021; MIL-STD-883 Method 1004; AEC-Q100, AEC-Q101, AEC-Q200; GR-468-CORE; JESD22-B104; MIL-STD-202 Method 213, Cond (A-F and J); MIL-STD-750 Method 2016; MIL-STD-883 Method 2002; ASTM D4169; GR-63-CORE sections 5.3.3 Parts I and II; AEC-Q100, AEC-Q101; JESD22-B103; MIL-STD-202 Method 201; MIL-STD-750 Method 2056; MIL-STD-883 Method 2007; MIL-STD-202 Method 214, Cond 1 (A-H), and Cond 2 (A-G); MIL-STD-883 Method 2026, Cond 1 (A-H), and Cond 2 (A-G); MIL-STD-750 Method 2046; ASTM D999 Method A1 Repetitive Shock (Vertical Motion); ASTM D4169 Schedule D Stacked Vibration, Schedule E Vehicle Vibration, Schedule F Loose Load Vibration; GR-63-CORE | - | -65 to 4000 °C; % RH; G’s; Hz |
| 3 | materials | JESD22-A110; JESD22-A118; AEC-Q100; JESD22-A108; JESD22-A102; AEC-Q100; AEC-Q101; JESD22-A113; J-STD-020; J-STD-035; AEC-Q100; AEC-Q101; AEC-Q200; JSTD-002; MIL-STD-750 Method 2026; MIL-STD-883 Method 2003; GR-326-CORE; GR-468-CORE; AEC-Q100; AEC-Q101; MIL-STD-202 Method 212; MIL-STD-750 Method 2006; MIL-STD-883 Method 2001; AEC-Q101; AEC-Q200; JESD22-B107; MIL-STD-202 Method 215; MIL-STD-750 Method 1022; MIL-STD-883 Method 2015; AEC-Q101; AEC-Q200; JESD22-B106; MIL-STD-202 Method 210; MIL-STD-750 Method 2031; MIL-STD-883 Method 2036; JESD22-B101; MIL-STD-750 Method 2071; MIL-STD-883 Method 2009; JESD22-B100; MIL-STD-883 Method 2016; MIL-STD-750 Method 2066 | - | to 50000 G’s |
| 4 | mechanical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- DDL, Inc. - DDL CAIrvine, CA · ~3,757 kmA2LAShares 2 accredited methods and materialsASTM D4169Medical devices
- Eurofins Infinity Laboratory GroupSan Jose, CA · ~3,950 kmA2LAShares 2 accredited methods and materialsASTM D4169Medical devices
- Eurofins LancasterLancaster, PA · ~46 kmA2LAShares 1 accredited test methodASTM D4169