Registers refreshed 2026-11-08.See refresh dates
China

Suzhou Efficiency Testing Technology Co.,

Room 201-2, Building 11, No. 101, Welfare Village, Guangfu Town, Wuzhong District, Suzhou, Suzhou Jiangsu, People's Republic of China, Suzhou Jiangsu, China

A2LA 7087.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
23
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 23 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC7
IEC 60669-1Some clauses

Limits written next to it

IEC 60669-1:2017 (exclude Clause 22.5 to 22.7, Inspections and

Some clauses. Written next to it on line 1 of A2LA certificate 7087.01.

IEC 60669-1:2017 (exclude Clause 22.5 to 22.7, Inspections and chemical tests on metals of current carrying parts)

Some clauses. Written next to it on line 1 of A2LA certificate 7087.01.

IEC 60669-2-1
IEC 61058-1-1
IEC 61058-1-2
IEC 61242Some clauses

Limits written next to it

IEC 61242:1995 +A1:2008+A2:2015 (exclude Clause 13,

Some clauses. Written next to it on line 1 of A2LA certificate 7087.01.

IEC 61242:1995 +A1:2008+A2:2015 (exclude Clause 13, Components, Clause 23.5, Current-carrying parts)

Some clauses. Written next to it on line 1 of A2LA certificate 7087.01.

IEC 61851-1
IEC 61984Some clauses

Limits written next to it

IEC 61984:2008 (exclude Clause 7.3.14, Corrosion test)

Some clauses. Written next to it on line 1 of A2LA certificate 7087.01.

IEC 60947 series4
IEC 60947-1
IEC 60947-3
IEC 60947-7-1
IEC 60947-7-2
IEC 60320 series3
IEC 60320-1
IEC 60320-2-4
IEC 60320-3
IEC 60884 series3
IEC 60884-1
IEC 60884-2-5
IEC 60884-2-7
IEC 60998 series3
IEC 60998-1
IEC 60998-2-1
IEC 60998-2-2
IEC 62196 series3
IEC 62196-1Some clauses

Limits written next to it

IEC 62196-1:2022 (exclude Clause 12.3, Short-time current

Some clauses. Written next to it on line 1 of A2LA certificate 7087.01.

IEC 62196-1:2022 (exclude Clause 12.3, Short-time current withstanding test of earthing contact

Some clauses. Written next to it on line 1 of A2LA certificate 7087.01.

IEC 62196-2Some clauses

Limits written next to it

IEC 62196-2:2022 (exclude Clause 12.3, Short-time current

Some clauses. Written next to it on line 1 of A2LA certificate 7087.01.

IEC 62196-2:2022 (exclude Clause 12.3, Short-time current withstanding test of earthing contact

Some clauses. Written next to it on line 1 of A2LA certificate 7087.01.

IEC 62196-3Some clauses

Limits written next to it

Product Safety (continued) IEC 62196-3:2022 (exclude Clause 12.3, Short-time current

Some clauses. Written next to it on line 2 of A2LA certificate 7087.01.

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

7087.01

The scope document we hold says it is valid until 2027-10-31.

View scope

Accredited scope, certificate 7087.01

LineMethodMatrixRange
1IEC 60884-1:2022; IEC60884-1:2002+A1:2006+A2:2013; IEC 60884-2-5:2017; IEC 60884-2-7:2011+A1:2013; IEC 61058-1:2016; IEC 61058-1-1:2016; IEC 61058-1-2:2016; IEC 60669-1:2017 (exclude Clause 22.5 to 22.7, Inspections and chemical tests on metals of current carrying parts); IEC 60669-2-1:2002+A1:2008+A2:2015; IEC 60998-1:2002; IEC 60998-2-1:2002; IEC 60998-2-2:2002; IEC 61984:2008 (exclude Clause 7.3.14, Corrosion test); IEC 60320-1:2021; IEC 60320-1:2015+A1:2018; IEC 60320-3:2014/AMD2:2022; IEC 60320-2-4:2018; IEC 61242:1995 +A1:2008+A2:2015 (exclude Clause 13, Components, Clause 23.5, Current-carrying parts); IEC 62196-1:2014; IEC 62196-1:2022 (exclude Clause 12.3, Short-time current withstanding test of earthing contact; exclude Clause 31, Short-circuit current withstand test); IEC 62196-2:2016; IEC 62196-2:2022 (exclude Clause 12.3, Short-time current withstanding test of earthing contact; exclude Clause 31, Short-circuit current withstand test); IEC 62196-3:2014--
2IEC 62196-3:2022; IEC 61851-1:2017; IEC 60947-1:2020; IEC 60947-7-1:2009; IEC 60947-7-2:2009; AS 60947.3:2023; IEC 60947-3:2020--
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SUZHOU EFFICIENCY TESTING TECHNOLOGY CO., LTD. Suzhou, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 30th day of September 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7087.01 Valid to October 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.