Registers refreshed 2026-11-08.See refresh dates
United States

LeakMaster

1992 South 100 West, Suite A, 47670, Princeton, IN, United States

Visit website
A2LA 6119.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
2
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 2 scope lines.

A2LA certificate 6119.01 · 2 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6119.01) 12/26/2024 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 LEAKMASTER, INC. 1992 South 100 West, Suite A Princeton, IN 47670 Barry Money Phone: 812 437 8378 CALIBRATION Valid To: February 28, 2027 Certificate Number: 6119.01 In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 3: I. Fluid Quantities Parameter/Equipment Range CMC 2, 4 (±) Comments Gas Flow Rate Into Atmosphere (Calibrated Leak Standard) (0.5 to 50) sccm (50 to 2000) sccm (2000 to 100 000) sccm 1.2 % or 0.10 sccm, whichever is greater 1.4 % 1.2 % Positive displacement primary piston prover for gas flow measurements ____________________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the small est uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 In the statement of CMC, percentages are percentage of reading unless otherwise indicated.
2ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1992 South 100 West, Suite A, Princeton, IN, 47670, US

38.35544, -87.56780

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.