Lorenz Calibration
327 Sandholm Street, 60134, Geneva, IL, United States
Visit website- Scope lines
- 2
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 2 scope lines.
A2LA certificate 3435.01 · 2 lines
Below is the text of the scope document as published.
Part 1 of 2
(A2LA Cert. No. 3435.01) Revised 11/12/2025 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 LORENZ CALIBRATION, INC. 327 Sandholm Street. Geneva, IL 60134 Zachary Lorenz Phone: 847 845 7400 CALIBRATION Valid To: March 31, 2027 Certificate Number: 3435.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Surface Plate – Flatness3 Repeat Reading3 Up to (72 x 144) in Up to 0.002 in (31 + 1.6DL) µin 33 µin Autocollimator Repeat reading gage ________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This laboratory performs field calibration activities for this parameter. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made f or aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, DL is the diagonal length of the unit under test in inches. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
Part 2 of 2
For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited LORENZ CALIBRATION, INC. Geneva, IL for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 10th day of June 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3435.01 Valid to March 31, 2027 Revised November 12, 2025
Extracted from the scope document; tables may not line up. View scope for the original.