Laboratorio Metrosens Cia. Ltda.
Pasaje Cicaos S2-51, Manuel Orozco, Quito, 170410, Ecuador, Quito, Ecuador
Visit website- Scope lines
- 29
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 29 scope lines.
A2LA certificate 7787.01 · 29 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | pH; Conductivity; Turbidity; Chlorine | - |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 2 of 28
Parameter/Equipment
Range CMC2 (±) Comments
Refractometers3
Up to 40 °Brix
(>40 to 66.67) °Brix
0.28 °Brix
0.15 °Brix
Calibration procedure
MET-PTC-33
II. Dimensional
Parameter/Equipment
Range
CMC2 (±)
Comments
Calipers – Outside,
Inside, & Depth
3
Digital
Analog
Up to 300 mm
Up to 11.8 in
(>300 to 500) mm
(>11.8 to 19.7) in
(>500 to 600) mm
(>19.7 to 23.6) in
Up to 600 mm
Up to 23.6 in
6.7 μm
0.000 26 in
6.8 μm
0.000 27 in
6.9 μm
0.000 27 in
12 μm
0.000 48 in
Calibration procedure
MET-PTC-17
Micrometers –
Outside, Inside &
Depth Micrometers &
Two Contacts
3 –
Digital
Up to 25 mm
Up to 1 in
(>25 to 50) mm
(>1 to 2) in
(>50 to 100) mm
(>2 to 4) in
(>100 to 300) mm
(>4 to 11.8) in
(>300 to 400) mm
(>12 to 16) in
(>400 to 500) mm
(>16 to 19.7) in
0.71 µm
0.000 028 in
0.76 µm
0.000 030 in
0.77 µm
0.000 030 in
0.69 µm
0.000 027 in
0.87 µm
0.000 034 in
1.1 µm
0.000 045 in
Calibration procedure
MET-PTC-18 | to 600 mm |
| 3 | - | Outside, Inside & Depth Micrometers & Two Contacts; Mechanical Thickness GagesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 3 of 28
Parameter/Equipment
Range
CMC2 (±)
Comments
Micrometers –
Outside, Inside &
Depth Micrometers &
Two Contacts3 – (cont)
Digital
Analog
(>500 to 600) mm
(>19.7 to 24) in
Up to 25 mm
Up to 1 in
(>25 to 100) mm
(>1 to 4) in
(>100 to 300) mm
(>4 to 11.8) in
(>300 to 400) mm
(>12 to 16) in
(>400 to 500) mm
(>16 to 19.7) in
(>500 to 600) mm
(>19.7 to 24) in
1.3 µm
0.000 050 in
1.4 µm
0.000 053 in
1.3 µm
0.000 050 in
1.2 µm
0.000 048 in
1.3 µm
0.000 050 in
1.5 µm
0.000 060 in
1.6 µm
0.000 063 in
Calibration
procedure MET-
PTC-18
Mechanical Thickness
Gages3
Up to 10 mm
Up to 0.4 in
(>10 to 15) mm
(>0.4 to 0.6) in
(>15 to 20) mm
(>0.6 to 0.8) in
(>20 to 25) mm
(>0.8 to 1) in
(>25 to 50) mm
(>1 to 2) in
0.71 µm
0.000 028 in
1.0 µm
0.000 040 in
0.71 µm
0.000 028 in
1.0 µm
0.000 040 in
0.74 µm
0.000 029 in
Calibration
procedure MET-
PTC-21 | to 600 mm |
| 4 | MET-PTC-21; MET-PTC-20; MET-PTC-41; MET-PTC-24; MET-PTC-26; MET-PTC-27 | Indicators; Analog & Digital Weld Gages; Rulers & Tapes & Oil Gauging Tapes; Sieves; Ultrasonic Thickness Gages; Coating Thickness Gage; Ultrasonic Flaw Detectors | - |
| 5 | - | Reference Blocks for Calibration of Ultrasonic Testing Instruments; Feeler/Thickness Gages; Plastic Shims; Optical & Stereo Microscopes, with Reticle; Dimensional – LengthShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 5 of 28
Parameter/Equipment
Range
CMC2 (±)
Comments
Reference Blocks for
Calibration of Ultrasonic
Testing Instruments3
Up to 25 mm
Up to 1 in
(>25 to 300) mm
(>1 to 9.8) in
1.1 µm
0.000 044 in
8.3 µm
0.000 33 in
Calibration procedure
MET-PTC-45
Feeler/Thickness Gages3
Up to 2 mm
Up to 0.078 in
1.1 µm
0.000 044 in
Calibration procedure
MET-PTC-22
Plastic Shims3
Up to 5000 µm
Up to 0.2 in
(>5000 to 8000) µm
(>0.2 to 0.31) in
1.1 µm
0.000 044 in
1.2 µm
0.000 046 in
Calibration procedure
MET-PTC-25
Optical & Stereo
Microscopes, with
Reticle3
Up to 400X
Magnification
1.2 μm
Calibration procedure
MET-PTC-46
III. Dimensional Testing
Parameter/Equipment
Range
CMC2 (±)
Comments
Dimensional – Length3
Up to 1 mm
Up to 0.039 in
Up to 10 mm
Up to 0.39 in
Up to 25 mm
Up to 1 in
Up to 300 mm
Up to 8 in
Up to 1000 mm
Up to 39.4 in
Up to 50 000 mm
Up to 1968.5 in
0.010 mm
0.000 39 in
0.082 mm
0.0032 in
0.058 mm
0.0022 in
0.059 mm
0.0023 in
0.59 mm
0.023 in
0.64 mm
0.025 in
Vision system with
reticule
Precision micrometer
Micrometer, caliper
Ruler
Tape master | to 50000 mm |
| 6 | MET-PTC-40 | - | - |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 7 of 28
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Current3 – Generate
(cont)
Clamp-On Meters3
Up to 25 A
(>25 to 50) A
(>50 to 75) A
(>75 to 150) A
(>150 to 250) A
(>250 to 1000) A
0.059 A
0.060 A
0.061 A
0.066 A
0.17 A
0.30 A
Calibration procedure
MET-PTC-40
Power DC– Generate 3
30 V:
(0.03 to 20) A
100 V:
(0.03 to 3) A
300 V:
(0.03 to 3) A
Up to 0.9 W
(>0.9 to 3) W
(>3 to 9) W
(>9 to 30) W
(>30 to 90) W
(>90 to 600) W
Up to 3 W
(>3 to 10) W
(>10 to 30) W
(>30 to 100) W
(>100 to 300) W
Up to 9 W
(>9 to 30) W
(>30 to 90) W
(>90 to 300) W
(>300 to 900) W
0.000 37 W
0.0013 W
0.0051 W
0.0093 W
0.022 W
0.19 W
0.0012 W
0.0043 W
0.018 W
0.032 W
0.074 W
0.0035 W
0.013 W
0.054 W
0.098 W
0.23 W
Calibration procedure
MET-PTC-40
Resistance – Generate3
Up to 10 Ω
(>10 to 100) Ω
(>0.1 to 1) kΩ
(>1 to 10) kΩ
(>10 to 100) kΩ
(>0.1 to 1) MΩ
(>1 to 10) MΩ
(>10 to 40) MΩ
(>40 to 200) MΩ
0.060 Ω
0.14 Ω
0.000 42 kΩ
0.0037 kΩ
0.054 kΩ
0.000 54 MΩ
0.061 MΩ
0.23 MΩ
1.2 MΩ
Calibration procedure
MET-PTC-40 | ||
| 8 | MET-PTC-40; MET-PTC-39 | - | - |
| 9 | MET-PTC-40 | AC Voltage; AC Current | - |
| 10 | - | AC Voltage; Power AC; Power Factor; Phase AngleShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 10 of 28
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(cont)
Clamp On Meters3:
Up to 25 A
(>25 to 50) A
(>50 to 75) A
(>75 to 150) A
(>150 to 250) A
(>250 to 1000) A
60 Hz to 1 kHz
0.061 A
0.065 A
0.081 A
0.10 A
0.34 A
0.60 A
Calibration procedure
MET-PTC-40
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Power AC– Generate 3
30 V:
(0.03 to 20) A
100 V:
(0.03 to 20) A
300 V:
(0.03 to 20) A
Up to 0.9 W
(>0.9 to 3) W
(>3 to 9) W
(>9 to 30) W
(>30 to 90) W
(>90 to 600) W
Up to 3 W
(>3 to 10) W
(>10 to 30) W
(>30 to 100) W
(>100 to 300) W
(>300 to 2000) W
Up to 9 W
(>9 to 30) W
(>30 to 90) W
(>90 to 300) W
(>300 to 900) W
(>900 to 6000) W
0.0011 W
0.0036 W
0.011 W
0.036 W
0.11 W
0.72 W
0.0036 W
0.012 W
0.036 W
0.12 W
0.36 W
2.4 W
0.011 W
0.036 W
0.11 W
0.36 W
1.1 W
7.2 W
Calibration procedure
MET-PTC-40
Power Factor – Generate3
(-1 to 1) p.u
0.000 77 p.u
Calibration procedure
MET-PTC-40
Phase Angle – Generate3
(-150 to 180) °
0.060 °
Calibration procedure
MET-PTC-40 | - |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 11 of 28
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage3 – Measure
Up to 1 mV
(>1 to 10) mV
(>10 to 20) mV
(>20 to 50) mV
(>50 to 75) mV
(>75 to 100) mV
(>100 to 190) mV
(>0.19 to 0.2) V
(>0.2 to 0.5) V
(>0.5 to 1) V
(>1 to 1.5) V
(>1.5 to 1.9) V
(>1.9 to 2) V
(>2 to 10) V
(>10 to 19) V
(>19 to 20) V
(>20 to 100) V
(>100 to 190) V
(>190 to 200) V
(>200 to 500) V
(>500 to 1000) V
0.0055 mV
0.0060 mV
0.0065 mV
0.0079 mV
0.0091 mV
0.010 mV
0.015 mV
0.000 023 V
0.000 036 V
0.000 057 V
0.000 078 V
0.000 095 V
0.000 19 V
0.000 58 V
0.0010 V
0.0024 V
0.0072 V
0.013 V
0.023 V
0.043 V
0.076 V
Calibration procedure
MET-PTC-19
DC Current3 – Measure
Up to 10 µA
(>10 to 20) µA
(>20 to 50) µA
(>50 to 100) µA
(>100 to 190) µA
(>0.19 to 0.2) mA
(>0.2 to 0.5) mA
(>0.5 to 1) mA
0.018 µA
0.024 µA
0.042 µA
0.072 µA
0.13 µA
0.000 17 mA
0.000 35 mA
0.000 65 mA
Calibration procedure
MET-PTC-19
DC Current3 – Measure
(>1 to 1.5) mA
(>1.5 to 1.9) mA
(>1.9 to 2) mA
(>2 to 4) mA
(>4 to 8) mA
(>8 to 10) mA
(>10 to 16) mA
(>16 to 19) mA
(>19 to 20) mA
(>20 to 50) mA
(>50 to 100) mA
(>100 to 190) mA
(>0.19 to 0.2) A
(>0.2 to 0.5) A
(>0.5 to 1) A
(>1 to 1.5) A
(>1.5 to 1.9) A
0.000 95 mA
0.0012 mA
0.0024 mA
0.0036 mA
0.0060 mA
0.0072 mA
0.011 mA
0.013 mA
0.017 mA
0.035 mA
0.065 mA
0.12 mA
0.000 53 A
0.000 89 A
0.0015 A
0.0021 A
0.0026 A
Calibration procedure
MET-PTC-19 | ||
| 12 | MET-PTC-19 | - | - |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 13 of 28
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance – Measure3
(cont)
(>10 to 50) MΩ
(>50 to 100) MΩ
0.49 MΩ
0.97 MΩ
Calibration procedure
MET-PTC-19
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure3
Up to 10 mV
(>10 to 20) mV
(>20 to 50) mV
(>50 to 100) mV
(>100 to 190) mV
(>0.19 to 0.2) V
(>0.2 to 0.5) V
(>0.5 to 1) V
(>1 to 1.5) V
(>1.5 to 1.9) V
(>1.9 to 2) V
(>2 to 10) V
(>10 to 19) V
(>19 to 20) V
(>20 to 100) V
(>100 to 190) V
(>190 to 200) V
(>200 to 500) V
(>500 to 750) V
60 Hz to 1 kHz
0.10 mV
0.11 mV
0.13 mV
0.17 mV
0.23 mV
0.000 87 V
0.0011 V
0.0014 V
0.0018 V
0.0021 V
0.012 V
0.019 V
0.028 V
0.12 V
0.19 V
0.28 V
0.46 V
0.75 V
0.99 V
Calibration procedure
MET-PTC-19
AC Current – Measure3
Up to 10 µA
(>10 to 20) µA
(>20 to 50) µA
(>50 to 100) µA
(>100 to 190) µA
(>0.19 to 0.2) mA
60 Hz to 1 kHz
0.16 µA
0.18 µA
0.23 µA
0.32 µA
0.49 µA
0.0013 mA
Calibration procedure
MET-PTC-19 | ||
| 14 | MET-PTC-19 | - | - |
| 15 | MET-PTC-19 | - | See scope document |
| 16 | MET-PTC-19; MET-PTC-16 | Thermocouples; RTD; Laboratory Glassware | See scope document |
| 17 | MET-PTC-16 | glassware | - |
| 18 | MET-PTC-16 | Glassware | See scope document |
| 19 | MET-PTC-16; MET-PTC-44; MET-PTC-34 | - | See scope document |
| 20 | MET-PTC-35; MET-PTC-08 | Petroleum Products | - |
| 21 | MET-PTC-06; MET-PTC-07; MET-PTC-42 | Pressure Gages; Calibrators; Pressure Safety Valve (PSV´s); Pressure Switch | See scope document |
| 22 | MET-PTC-12 | OIML Classes F1, F2, M1, M1-2, M2, M2-3, M3; OIML Classes F2, M1, M1-2, M2, M2-3, M3; OIML Classes M1-2, M2, M2-3, M3 | See scope document |
| 23 | MET-PTC-11; MET-PTC-38 | - | - |
| 24 | MET-PTC-36; MET-PTC-05 | - | - |
| 25 | - | Digital Thermometers with RTD sensors (Thermistors, Thermocouples, Thermometers Bimetallic With Pattern Sensor); Bi-Metal Thermometers; Liquid-In-Glass Thermometers; Temperature Transmiters; Infrared Temperature – Measuring EquipmentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 25 of 28
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Digital Thermometers3
with RTD sensors
(Thermistors,
Thermocouples,
Thermometers Bimetallic
With Pattern Sensor).
(-40 to -20) °C
(>-20 to 0) °C
(>0 to 30) °C
(>30 to 80) °C
(>80 to 150) °C
(>150 to 200) °C
(>200 to 420) °C
0.047 °C
0.052 °C
0.049 °C
0.080 °C
0.085 °C
0.090 °C
0.093 °C
Calibration
procedure
MET-PTC-01
Bi-Metal Thermometers3
(-40 to 30) °C
(>30 to 420) °C
0.15 °C
0.17 °C
Calibration
procedure
MET-PTC-02
Liquid-In-Glass
Thermometers3
-40 °C
(>-40 to -20) °C
(>-20 to 0) °C
(>0 to 30) °C
(>30 to 80) °C
(>80 to 150) °C
(>150 to 200) °C
(>200 to 420) °C
0.049 °C
0.050 °C
0.055 °C
0.052 °C
0.081 °C
0.086 °C
0.092 °C
0.094 °C
Calibration
procedure
MET-PTC-32
Temperature Transmiters3
(-40 to -20) °C
(>-20 to 0) °C
(>0 to 30) °C
(>30 to 80) °C
(>80 to 150) °C
(>150 to 200) °C
(>200 to 300) °C
(>300 to 420) °C
0.043 °C
0.041 °C
0.044 °C
0.059 °C
0.067 °C
0.074 °C
0.086 °C
0.082 °C
Calibration
procedure
MET-PTC-43
Infrared Temperature –
Measuring Equipment
-20 °C
(>-20 to 0) °C
(>0 to 30) °C
(>30 to 80) °C
(>80 to 125) °C
(>125 to 150) °C
(>150 to 175) °C
(>175 to 200) °C
(>200 to 300) °C
(>300 to 420) °C
0.63 °C
0.30 °C
0.19 °C
0.62 °C
0.98 °C
1.2 °C
1.4 °C
1.6 °C
2.4 °C
3.4 °C
Calibration
procedure
MET-PTC-31
Emissivity:
Ɛ = 0.95 | See scope document |
| 26 | - | Humidity; Temperature; Timers & Chronometers; Hour-MeterShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 26 of 28
Parameter/Equipment
Range
CMC2 (±)
Comments
Climatic Chambers
(Including Isothermal
Environments, Autoclaves,
Cold Rooms, Centrifuges,
Dry Wells, Environmental
Chambers, Freezers,
Furnaces, Incubators,
Liquid Baths, Muffle
Furnaces, Ovens,
Refrigerators, Stability
Rooms, Sterile Rooms,
Thermoreactors, Trucks,
Warehouses, Weather
Chambers)
3
Humidity
Temperature
(10 to 50) % RH
(>50 to 90) % RH
-40 °C
(>-40 to 0) °C
(>0 to 50) °C
(>50 to 150) °C
(>150 to 200) °C
(>200 to 420) °C
(>420 to 900) °C
(>900 to 1084) °C
0.91 % RH
1.0 % RH
0.021 °C
0.022 °C
0.025 °C
0.038 °C
0.043 °C
0.048 °C
0.54 °C
0.83 °C
Calibration
procedure
MET-PTE-01
IX. Time and Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
Timers & Chronometers3
(0 to 180) s
(>180 to 600) s
(>600 to 1800) s
(>1800 to 3600) s
(>3600 to 7200) s
(>7200 to 14 400) s
(>14 400 to 18 000) s
0.027 s
0.028 s
0.037 s
0.063 s
0.12 s
0.24 s
0.28 s
Calibration
procedure
MET-PTC-09
Hour-Meter3
Up to 18 000 s
(>18 000 to 86 400) s
0.53 s
0.55 s
Calibration
procedure
MTC-PTC-10 | - |
| 27 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 27 of 28
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Centrifuges & Rotational
Devices3
Up to 900 rpm
(>900 to 3000) rpm
(>3000 to 12 000) rpm
(>12 000 to 20 000) rpm
(>20 000 to 30 000) rpm
(>30 000 to 60 000) rpm
0.15 rpm
0.83 rpm
1.1 rpm
1.2 rpm
1.5 rpm
2.3 rpm
Calibration
procedure
MTC-PTC-30
Frequency– Measuring
Equipment3
Up to 10 Hz
(>10 to 40) Hz
(>40 to 50) Hz
(>50 to 100) Hz
(>100 to 400) Hz
(>400 to 1000) Hz
(>1 to 10) kHz
(>10 to 100) kHz
(>100 to 500) kHz
0.0012 Hz
0.0047 Hz
0.0059 Hz
0.012 Hz
0.023 Hz
0.059 Hz
0.000 59 kHz
0.0059 kHz
0.029 kHz
Calibration
procedure MET-
PTC-40
Frequency– Measure3
Up to 3 Hz
(>3 to 4) Hz
(>4 to 5) Hz
(>5 to 6) Hz
(>6 to 7) Hz
(>7 to 8) Hz
(>8 to 9) Hz
(>9 to 10) Hz
(>10 to 20) Hz
(>20 to 30) Hz
(>30 to 40) Hz
(>40 to 50) Hz
(>50 to 100) Hz
(>100 to 500) Hz
(>0.5 to 1) kHz
(>1 to 10) kHz
(>10 to 100) kHz
(>100 to 300) kHz
(>300 to 400) kHz
(>400 to 500) kHz
(>500 to 600) kHz
(>600 to 800) kHz
(>0.8 to 1) MHz
0.0025 Hz
0.0033 Hz
0.0042 Hz
0.0028 Hz
0.0033 Hz
0.0038 Hz
0.0043 Hz
0.0047 Hz
0.0050 Hz
0.0076 Hz
0.0057 Hz
0.0042 Hz
0.0083 Hz
0.042 Hz
0.000 083 kHz
0.000 83 kHz
0.0083 kHz
0.025 kHz
0.033 kHz
0.042 kHz
0.050 kHz
0.067 kHz
0.000 083 MHz
Calibration
procedure MET-
PTC-19
___________________________________________
1 This laboratory offers commercial calibration service. | to 60000 rpm |
| 28 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7787.01) Revised 8/3/2026 Page 28 of 28
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 In the statement of CMC, L is the length of the measure device under test. | ||
| 29 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Pasaje Cicaos S2-51, Manuel Orozco, Quito, 170410, Ecuador, Quito, EC
-0.22016, -78.51233
Open in MapsOther Locations
1 other site in this organization
Accreditation data refreshed from the A2LA register on .