Registers refreshed 2026-11-08.See refresh dates
Sweden

INOVYN Sverige

Hjälmarevägen 30, 444 83, Stenungsund, Sweden

SWEDAC a000440-001SWEDAC A000440-001ISO/IEC 17025Register refreshed 2026-11-08

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
9
SWEDAC certificates
2
Site in our directory
1
SWEDAC accredited scope

What this lab is accredited for

Our reading of the SWEDAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 9 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters

Certificate says EN 872:2005 Gravimetri. Probably the same standard; not checked against the EN document.

EN 1483Water quality - Determination of mercury - Method using atomic absorption spectrometry
EN 13346Characterization of sludges - Determination of trace elements and phosphorus - Aqua regia extraction methods
ISO 1483Slotted raised countersunk (oval) head tapping screws
ISO 10301Water quality - Determination of highly volatile halogenated hydrocarbons - Gas-chromatographic methods
ISO 10304-4Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
ISO 10523Water quality - Determination of pH
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
ISO 20236Water quality - Determination of total organic carbon (TOC), dissolved organic carbon (DOC), total bound nitrogen (TNb) and dissolved bound nitrogen (DNb) after high temperature catalytic oxidative combustion

Read from the scope as published by SWEDAC. Register refreshed 2026-11-08.

Scope as published by SWEDAC

4 lines
SWEDAC

ISO/IEC 17025

Active

a000440-001

View on SWEDAC

Accredited scope, certificate a000440-001

LineMethodMatrixRange
1SS-EN ISO/IEC 17025:2018 INOVYN Sverige AB Stenungsund Ackrediteringsnummer 1154 Laboratoriet A000440-001 Kemisk analys Teknikomr; SS-EN ISO 16911-1:2013 Pitotr; SS-EN 1483:2007 FIMS 0; SS-EN ISO 1483:2007; SS-EN 13346:2000 FIMS 0Flue gasSee scope document
2SS-EN ISO 10301:1997 GC; SS-EN ISO 10304-4:2022 Jonkromatografi 0; SS-EN ISO 20236:2025 F; SS-EN ISO 10523:2012 Elektrod 3-11 pH-enheter Avloppsvatten/Lakvatten Elektrod 3-11 pH-enheter S; SS-EN 872:2005 GravimetriSewageSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

SWEDAC

ISO/IEC 17025

Active

A000440-001

View on SWEDAC

Accredited scope, certificate A000440-001

LineMethodMatrixRange
1SS-EN ISO/IEC 17025:2018; SS-EN ISO 16911-1:2013; SS-EN 1483:2007; SS-EN ISO 10301:1997; VAM 728-1Flue gasSee scope document
2SS-EN ISO 10304-4:2022; SS-EN ISO 20236:2025; SS-EN ISO 10523:2012; SS-EN 872:2005SewageSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Hjälmarevägen 30, Stenungsund, 444 83, SE

58.07851, 11.82239

Open in Maps

Accreditation data refreshed from the SWEDAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the SWEDAC entry linked above.