MP Components
1805 Lemon Farris Road, 38506, Cookeville, TN, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 2247.02 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | SteelShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2247.02) 11/11/2024 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
MP COMPONENTS, LLC
1805 Lemon Farris Road
Cookeville, TN 38506
Randy Veldhouse Phone: 616 878 9710
MECHANICAL
Valid To: October 31, 2026 Certificate Number: 2247.02
In recognition of the successful completion of the A2LA evaluation process accreditation is granted to this
laboratory to perform the following dimensional testing
1, 5:
I. Dimensional Testing
3
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
3D Measurements –
Steel
Aluminum
Non-Metal
Steel
Aluminum
Non-Metal
Up to (40 × 60 × 35) in
Up to (78 × 130 × 60) in
(550 + 43L) µin
(560 + 54L) µin
(560 + 110L) µin
(930 + 36L) µin
(930 + 47L) µin
(940 + 100L) µin
Bridge CMM
(Chameleon 1298-
2490)
Gantry CMM
(Alpha 018)
Length – Outside
Diameter
Up to 4 in
0.0001 in
Micrometer
____________________________________________
1 This laboratory offers commercial dimensional testing service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | to 78 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2247.02) 11/11/2024 Page 2 of 2
3 This test is not equivalent to that of a calibration.
4 In the statement of CMC, L represents the numerical value of the nominal length of the device measured
in inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Accu-ChekCorydon, IN · ~235 kmA2LAShares 1 accredited materialSteel
- Certified MeasurementsCenterville, GA · ~426 kmA2LAShares 1 accredited materialSteel
- Siemens Energy, Inc Charlotte Materials and Joining CenterCharlotte, NC · ~433 kmA2LAShares 1 accredited materialSteel
- Advanced Technology ServicesPeoria, IL · ~627 kmA2LAShares 1 accredited materialSteel
- All American Scales & CalibrationParis, OH · ~639 kmA2LAShares 1 accredited materialSteel
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.