Rudolph Research Analytical

55 Newburgh Road, 07840, Hackettstown, NJ, United States

Visit website
A2LA 7528.01A2LA 7528.02ISO/IEC 17025ISO 17034Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
6
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 7528.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7528.01) 2/13/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 RUDOLPH RESEARCH ANALYTICAL 55 Newburgh Road Hackettstown, NJ 07840 Heidi Spanier Phone: 973 584 1558 CALIBRATION Valid To: November 30, 2027 Certificate Number: 7528.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter/Equipment Range CMC2, 7 (±) Comments Quartz Control Plates (546.2271 nm)6 (-41 to < -30) ° (-30 to 41) ° 0.0030 ° 0.0020 ° Indirect comparison to standard quartz control plate Polarimeters (546 nm, 589 nm, 633 nm)3 (-41 to -29) ° (> -29 to -24) ° (> -24 to -15) ° (> -15 to -4) ° (> -4 to 4) ° (>4 to 16) ° (>16 to 24) ° (>24 to 29) ° (>29 to 32) ° (>32 to 39) ° (>39 to 41) ° (-0.000 13α + 0.0018) ° (-0.000 12α + 0.0016) ° (-0.000 11α + 0.0018) ° (-0.000 07α + 0.0024) ° 0.0026 ° (0.000 07α + 0.0024) ° (0.000 11α + 0.0018) ° (0.000 12α + 0.0016) ° (0.000 13α + 0.0013) ° (0.000 13α + 0.0014) ° (0.000 14α + 0.0011) ° Direct comparison to quartz control plate
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7528.01) 2/13/2026 Page 2 of 2 II. Mechanical Parameter/Equipment Range CMC2 (±) Comments Density – Density Meters3 (0.65 to 1.8) g/cm3 0.000 011 g/cm3 Indirect comparison to liquid reference standards III. Thermodynamics Parameter/Equipment Range CMC2, 4 (±) Comments Temperature – Measuring Equipment (20 to 30) °C 0.007 °C Direct comparison to Fluke 5642 probe with 1504 meter _______________________________ 1 This laboratory offers commercial calibration services and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 Optical rotation values for other wavelengths provided in accordance with the formula ICUMSA SPS-1 7 In the statement of CMC, α is the measured angle of rotation.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA certificate 7528.02 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17034:2016; ICUMSA SPS-3 (2000)Liquid Solvents and SolutionsSee scope document
2ICUMSA SPS-1Quartz Control Plate; QuartzSee scope document
3ISO 17034:2016--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.