What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 7528.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7528.01) 2/13/2026 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
RUDOLPH RESEARCH ANALYTICAL
55 Newburgh Road
Hackettstown, NJ 07840
Heidi Spanier Phone: 973 584 1558
CALIBRATION
Valid To: November 30, 2027 Certificate Number: 7528.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Dimensional
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Quartz Control Plates
(546.2271 nm)6
(-41 to < -30) °
(-30 to 41) °
0.0030 °
0.0020 °
Indirect comparison
to standard quartz
control plate
Polarimeters
(546 nm, 589 nm, 633
nm)3
(-41 to -29) °
(> -29 to -24) °
(> -24 to -15) °
(> -15 to -4) °
(> -4 to 4) °
(>4 to 16) °
(>16 to 24) °
(>24 to 29) °
(>29 to 32) °
(>32 to 39) °
(>39 to 41) °
(-0.000 13α + 0.0018) °
(-0.000 12α + 0.0016) °
(-0.000 11α + 0.0018) °
(-0.000 07α + 0.0024) °
0.0026 °
(0.000 07α + 0.0024) °
(0.000 11α + 0.0018) °
(0.000 12α + 0.0016) °
(0.000 13α + 0.0013) °
(0.000 13α + 0.0014) °
(0.000 14α + 0.0011) °
Direct comparison
to quartz control
plate | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7528.01) 2/13/2026 Page 2 of 2
II. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Density –
Density Meters3
(0.65 to 1.8) g/cm3
0.000 011 g/cm3
Indirect comparison
to liquid reference
standards
III. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature –
Measuring Equipment
(20 to 30) °C
0.007 °C
Direct comparison
to Fluke 5642 probe
with 1504 meter
_______________________________
1 This laboratory offers commercial calibration services and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The usual allowance for the uncertainty
introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 Optical rotation values for other wavelengths provided in accordance with the formula ICUMSA SPS-1
7 In the statement of CMC, α is the measured angle of rotation. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
A2LA certificate 7528.02 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17034:2016; ICUMSA SPS-3 (2000) | Liquid Solvents and Solutions | See scope document |
| 2 | ICUMSA SPS-1 | Quartz Control Plate; Quartz | See scope document |
| 3 | ISO 17034:2016 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.