Registers refreshed 2026-11-08.See refresh dates
Canada

Endress+Hauser Canada

Burlington, Canada

Visit website
A2LA 3597.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 3597.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017Water; Pneumatic, Gauge Pressure-
2-Pneumatic, Gauge Pressure; RTD Thermometers; pH Measuring Instruments; Conductivity Measuring Instruments
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3597.01) Revised 7/15/2026 Page 2 of 3 Parameter/Equipment Range CMC2 (±) Comments Vacuum/Pressure3 – Gauges and Transducers (cont) Pneumatic, Gauge Pressure (-15 to 300) psi (0 to 1500) psi 0.11 psi 0.79 psi Beamex MC6-Series w/EXT20C Fluke 72x/75x w/ 700P09 III. Thermodynamic Parameter/Equipment Range CMC2 (±) Comments Temperature3 – RTD Thermometers (-30 to 350) °C 0.16 °C Beamex MC6-Series field calibrator & dry- block with precision RTD temperature probe IV. Chemical Parameter/Equipment Range CMC2 (±) Comments pH – Measuring Instruments3 (1 to 14) pH 0.03 pH ISO 17034 certified pH buffer standards Conductivity – Measuring Instruments3 100 µS/cm 1000 µS/cm 10 000 µS/cm 100 000 µS/cm 200 000 µS/cm 3 µs/cm 8 µs/cm 80 µs/cm 500 µs/cm 820 µs/cm ISO 17034 certified conductivity standard solutions _______________________________________________________________ 1 This laboratory offers commercial calibration and field calibration services, where noted.
See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3597.01) Revised 7/15/2026 Page 3 of 3 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, the value is defined as the percentage of reading, unless otherwise noted. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
4ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.