E.S.R. Services
551 Fifth St. Unit B2, 91340, San Fernando, CA, United States
Visit website- Scope lines
- 7
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 7 scope lines.
A2LA certificate 2523.01 · 7 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2523.01) Revised 03/03/2026 Page 1 of 5
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
E.S.R SERVICES INC.
551 Fifth St. Unit B2
San Fernando, CA. 91340
Mr. Robert Abrahamian Phone: 818 500 0787
CALIBRATION
Valid To: January 31, 2027 Certificate Number: 2523.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory to perform the following calibrations
1, 6:
I. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 3 (±) Comments
DC Voltage – Generate
(0 to 19.9999) mV
(20 to 199.999) mV
(0.2 to 1.999 99) V
(2 to 19.9999) V
(20 to 199.999) V
(200 to 1100) V
0.012 % + 10 µV
0.0093 % + 14 µV
0.0098 % + 50 µV
0.01 % + 0.41 mV
0.0095 % + 4.0 mV
0.0099 % + 20 mV
Fluke 5100B
calibrator
DC Voltage – Measure
(0 to 19.9999) mV
(20 to 199.999) mV
(0.2 to 1.999 99) V
(2 to 19.9999) V
(20 to 199.999) V
(200 to 1000) V
0.014 % + 3.0 µV
0.0082 % + 3.0 µV
0.0049 % + 20 µV
0.0058 % + 0.2 mV
0.0046 % + 2.0 mV
0.0065 % + 20 mV
Fluke 8842A DMM
DC Current – Generate
(10 to 199.999) µA
(0.2 to 1.999 99) mA
(2 to 19.9999) mA
(20 to 199.999) mA
(0.2 to 1.999 99) A
0.59 % + 48 nA
0.069 % + 0.12 µA
0.035 % + 0.84 µA
0.035 % + 8.0 µA
0.035 % + 80 µA
Fluke 5100B
calibrator
DC Current – Measure
1 mA to 1 A
(> 1 to 1.999 99) A
0.058 % + 40 µA
0.12 % + 40 µA
Fluke 8842A DMM | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2523.01) Revised 03/03/2026 Page 2 of 5
Parameter/Equipment
Range CMC2, 3, 4 (±) Comments
Resistance – Generate,
Fixed Points
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
0.039 %
0.024 %
0.0092 %
0.0091 %
0.0091 %
0.0091 %
0.024 %
0.07 %
Fluke 5100B
calibrator
Resistance – Measure
(1 to 19.9999) Ω
(20 to 199.999) Ω
(0.2 to 1.999 99) kΩ
(2 to 19.9999) kΩ
(20 to 199.999) kΩ
(0.2 to 1.999 99) MΩ
(2 to 19.9999) MΩ
0.017 % + 4.0 mΩ
0.013 % + 4.0 mΩ
0.011 % + 30 mΩ
0.011 % + 0.30 Ω
0.013 % + 3.0 Ω
0.032 % + 30 Ω
0.049 % + 0.40 kΩ
Fluke 8842A DMM
Parameter/Range
Frequency CMC2, 3 (±) Comments
AC Voltage – Generate
(1 to 19.9999) mV
(20 to 199.999) mV
(50 to 100) Hz in
increments of 10 Hz
(0.1 to 1) kHz in
increments of 100 Hz
(1 to 10) kHz in
increments of 1 kHz
(10 to 50) kHz in
increments of 10 kHz
(50 to 100) Hz in
increments of 10 Hz
(0.1 to 1) kHz in
increments of 100 Hz
(1 to 10) kHz in
increments of 1 kHz
(10 to 50) kHz in
increments of 10 kHz
0.084 % + 0.1 mV
0.084 % + 0.1 mV
0.084 % + 0.1 mV
0.14 % + 0.1 mV
0.081 % + 0.12 mV
0.081 % + 0.12 mV
0.081 % + 0.12 mV
0.14 % + 0.13 mV
Fluke 5100B
calibrator | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2523.01) Revised 03/03/2026 Page 3 of 5
Parameter/Range
Frequency CMC2, 3 (±) Comments
AC Voltage – Generate
(cont)
(0.2 to 1.999 99) V
(2 to 19.9999) V
(20 to 110) V
(> 110 to 199.999) V
(200 to 1100) V
(50 to 100) Hz in
increments of 10 Hz
(0.1 to 1) kHz in
increments of 100 Hz
(1 to 10) kHz in
increments of 1 kHz
(10 to 50) kHz in
increments of 10 kHz
(50 to 100) Hz in
increments of 10 Hz
(0.1 to 1) kHz in
increments of 100 Hz
(1 to 10) kHz in
increments of 1 kHz
(10 to 50) kHz in
increments of 10 kHz
(50 to 100) Hz in
increments of 10 Hz
(0.1 to 1) kHz in
increments of 100 Hz
(1 to 10) kHz in
increments of 1 kHz
20 kHz
(50 to 100) Hz in
increments of 10 Hz
(0.1 to 1) kHz in
increments of 100 Hz
(50 to 100) Hz in
increments of 10 Hz
(0.1 to 1) kHz in
increments of 100 Hz
0.083 % + 0.3 mV
0.083 % + 0.3 mV
0.083 % + 0.3 mV
0.14 % + 0.42 mV
0.081 % + 2.1 mV
0.081 % + 2.1 mV
0.081 % + 2.1 mV
0.14 % + 3.3 mV
0.081 % + 20 mV
0.081 % + 20 mV
0.081 % + 20 mV
0.14 % + 32 mV
0.081 % + 20 mV
0.081 % + 20 mV
0.081 % + 0.11 V
0.081 % + 0.11 V
Fluke 5100B
calibrator | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2523.01) Revised 03/03/2026 Page 4 of 5
Parameter/Range
Frequency CMC2, 3 (±) Comments
AC Voltage – Measure
(1 to 199.999) mV
(0.2 to 1.999 99) V
(2 to 19.9999) V
(20 to 199.999) V
(200 to 700) V
(20 to 45) Hz
(45 to 200) Hz
(0.2 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(20 to 45) Hz
(45 to 200) Hz
(0.2 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(20 to 45) Hz
(45 to 200) Hz
(0.2 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(20 to 45) Hz
(45 to 200) Hz
(0.2 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(20 to 45) Hz
(45 to 200) Hz
(0.2 to 20) kHz
1.4 % + 0.1 mV
0.47 % + 0.1 mV
0.13 % + 0.1 mV
0.25 % + 0.2 mV
0.58 % + 0.4 mV
1.4 % + 1.0 mV
0.46 % + 1.0 mV
0.094 % + 0.8 mV
0.24 % + 2.0 mV
0.58 % + 4.0 mV
1.4 % + 10 mV
0.46 % + 10 mV
0.094 % + 8.0 mV
0.24 % + 20 mV
0.58 % + 40 mV
1.4 % + 100 mV
0.46 % + 100 mV
0.093 % + 80 mV
0.24 % + 200 mV
0.58 % + 400 mV
1.4 % + 1.0 V
0.46 % + 1.0 V
0.12 % + 1.0 V
Fluke 8842A
DMM
AC Current – Generate
0.2 mA to < 2.0 A
50 Hz to 1 kHz
0.12 % + 0.20 mA
Fluke 5100B
calibrator
AC Current – Measure
2000 mA
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
2.4 % + 2.0 mA
0.58 % + 2.0 mA
0.46 % + 2.0 mA
Fluke 8842A DMM | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2523.01) Revised 03/03/2026 Page 5 of 5
II. Optical Quantities
Parameter/Equipment
Range CMC2, 5 (±) Comments
Optical Power – Measure,
Multi-Mode (MM)
All to 2 dBm Max
635 nm (± 30 nm)
850 nm (± 30 nm)
1300 nm (± 30 nm)
0.59 dBm
RIFOCS/tempo OPM
system
Optical Attenuation (Att.)
and Insertion Loss (IL.) –
Measure, Multi-Mode (MM)
Measurement
All to 2 dBm Max
635 nm (± 30 nm)
850 nm (± 30 nm)
1300 nm (± 30 nm)
0.59 dB
RIFOCS/tempo OPM
system
Optical Power – Measure,
Single Mode (SM)
Measurement – Laser Only
1310 nm, 1490 nm
1550 nm, 1625 nm
All (± 30 nm)
0.59 dBm
RIFOCS/tempo OPM
system
Optical Attenuation (Att.)
and Insertion Loss (IL.) –
Measure, Single Mode (SM)
Measurement – Laser Only
1310 nm, 1490 nm
1550 nm, 1625 nm
All (± 30 nm)
0.59 dB
RIFOCS/tempo OPM
system
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as eithe r a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | to 2 dBm |
| 6 | ISO/IEC 17025:2017; R205 | - | - |
| 7 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.