Registers refreshed 2026-11-08.See refresh dates
United States

E.S.R. Services

551 Fifth St. Unit B2, 91340, San Fernando, CA, United States

Visit website
A2LA 2523.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
7
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 2523.01 · 7 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2523.01) Revised 03/03/2026 Page 1 of 5 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 E.S.R SERVICES INC. 551 Fifth St. Unit B2 San Fernando, CA. 91340 Mr. Robert Abrahamian Phone: 818 500 0787 CALIBRATION Valid To: January 31, 2027 Certificate Number: 2523.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 3 (±) Comments DC Voltage – Generate (0 to 19.9999) mV (20 to 199.999) mV (0.2 to 1.999 99) V (2 to 19.9999) V (20 to 199.999) V (200 to 1100) V 0.012 % + 10 µV 0.0093 % + 14 µV 0.0098 % + 50 µV 0.01 % + 0.41 mV 0.0095 % + 4.0 mV 0.0099 % + 20 mV Fluke 5100B calibrator DC Voltage – Measure (0 to 19.9999) mV (20 to 199.999) mV (0.2 to 1.999 99) V (2 to 19.9999) V (20 to 199.999) V (200 to 1000) V 0.014 % + 3.0 µV 0.0082 % + 3.0 µV 0.0049 % + 20 µV 0.0058 % + 0.2 mV 0.0046 % + 2.0 mV 0.0065 % + 20 mV Fluke 8842A DMM DC Current – Generate (10 to 199.999) µA (0.2 to 1.999 99) mA (2 to 19.9999) mA (20 to 199.999) mA (0.2 to 1.999 99) A 0.59 % + 48 nA 0.069 % + 0.12 µA 0.035 % + 0.84 µA 0.035 % + 8.0 µA 0.035 % + 80 µA Fluke 5100B calibrator DC Current – Measure 1 mA to 1 A (> 1 to 1.999 99) A 0.058 % + 40 µA 0.12 % + 40 µA Fluke 8842A DMM
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2523.01) Revised 03/03/2026 Page 2 of 5 Parameter/Equipment Range CMC2, 3, 4 (±) Comments Resistance – Generate, Fixed Points 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 0.039 % 0.024 % 0.0092 % 0.0091 % 0.0091 % 0.0091 % 0.024 % 0.07 % Fluke 5100B calibrator Resistance – Measure (1 to 19.9999) Ω (20 to 199.999) Ω (0.2 to 1.999 99) kΩ (2 to 19.9999) kΩ (20 to 199.999) kΩ (0.2 to 1.999 99) MΩ (2 to 19.9999) MΩ 0.017 % + 4.0 mΩ 0.013 % + 4.0 mΩ 0.011 % + 30 mΩ 0.011 % + 0.30 Ω 0.013 % + 3.0 Ω 0.032 % + 30 Ω 0.049 % + 0.40 kΩ Fluke 8842A DMM Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (1 to 19.9999) mV (20 to 199.999) mV (50 to 100) Hz in increments of 10 Hz (0.1 to 1) kHz in increments of 100 Hz (1 to 10) kHz in increments of 1 kHz (10 to 50) kHz in increments of 10 kHz (50 to 100) Hz in increments of 10 Hz (0.1 to 1) kHz in increments of 100 Hz (1 to 10) kHz in increments of 1 kHz (10 to 50) kHz in increments of 10 kHz 0.084 % + 0.1 mV 0.084 % + 0.1 mV 0.084 % + 0.1 mV 0.14 % + 0.1 mV 0.081 % + 0.12 mV 0.081 % + 0.12 mV 0.081 % + 0.12 mV 0.14 % + 0.13 mV Fluke 5100B calibrator
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2523.01) Revised 03/03/2026 Page 3 of 5 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (cont) (0.2 to 1.999 99) V (2 to 19.9999) V (20 to 110) V (> 110 to 199.999) V (200 to 1100) V (50 to 100) Hz in increments of 10 Hz (0.1 to 1) kHz in increments of 100 Hz (1 to 10) kHz in increments of 1 kHz (10 to 50) kHz in increments of 10 kHz (50 to 100) Hz in increments of 10 Hz (0.1 to 1) kHz in increments of 100 Hz (1 to 10) kHz in increments of 1 kHz (10 to 50) kHz in increments of 10 kHz (50 to 100) Hz in increments of 10 Hz (0.1 to 1) kHz in increments of 100 Hz (1 to 10) kHz in increments of 1 kHz 20 kHz (50 to 100) Hz in increments of 10 Hz (0.1 to 1) kHz in increments of 100 Hz (50 to 100) Hz in increments of 10 Hz (0.1 to 1) kHz in increments of 100 Hz 0.083 % + 0.3 mV 0.083 % + 0.3 mV 0.083 % + 0.3 mV 0.14 % + 0.42 mV 0.081 % + 2.1 mV 0.081 % + 2.1 mV 0.081 % + 2.1 mV 0.14 % + 3.3 mV 0.081 % + 20 mV 0.081 % + 20 mV 0.081 % + 20 mV 0.14 % + 32 mV 0.081 % + 20 mV 0.081 % + 20 mV 0.081 % + 0.11 V 0.081 % + 0.11 V Fluke 5100B calibrator
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2523.01) Revised 03/03/2026 Page 4 of 5 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Measure (1 to 199.999) mV (0.2 to 1.999 99) V (2 to 19.9999) V (20 to 199.999) V (200 to 700) V (20 to 45) Hz (45 to 200) Hz (0.2 to 20) kHz (20 to 50) kHz (50 to 100) kHz (20 to 45) Hz (45 to 200) Hz (0.2 to 20) kHz (20 to 50) kHz (50 to 100) kHz (20 to 45) Hz (45 to 200) Hz (0.2 to 20) kHz (20 to 50) kHz (50 to 100) kHz (20 to 45) Hz (45 to 200) Hz (0.2 to 20) kHz (20 to 50) kHz (50 to 100) kHz (20 to 45) Hz (45 to 200) Hz (0.2 to 20) kHz 1.4 % + 0.1 mV 0.47 % + 0.1 mV 0.13 % + 0.1 mV 0.25 % + 0.2 mV 0.58 % + 0.4 mV 1.4 % + 1.0 mV 0.46 % + 1.0 mV 0.094 % + 0.8 mV 0.24 % + 2.0 mV 0.58 % + 4.0 mV 1.4 % + 10 mV 0.46 % + 10 mV 0.094 % + 8.0 mV 0.24 % + 20 mV 0.58 % + 40 mV 1.4 % + 100 mV 0.46 % + 100 mV 0.093 % + 80 mV 0.24 % + 200 mV 0.58 % + 400 mV 1.4 % + 1.0 V 0.46 % + 1.0 V 0.12 % + 1.0 V Fluke 8842A DMM AC Current – Generate 0.2 mA to < 2.0 A 50 Hz to 1 kHz 0.12 % + 0.20 mA Fluke 5100B calibrator AC Current – Measure 2000 mA (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz 2.4 % + 2.0 mA 0.58 % + 2.0 mA 0.46 % + 2.0 mA Fluke 8842A DMM
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2523.01) Revised 03/03/2026 Page 5 of 5 II. Optical Quantities Parameter/Equipment Range CMC2, 5 (±) Comments Optical Power – Measure, Multi-Mode (MM) All to 2 dBm Max 635 nm (± 30 nm) 850 nm (± 30 nm) 1300 nm (± 30 nm) 0.59 dBm RIFOCS/tempo OPM system Optical Attenuation (Att.) and Insertion Loss (IL.) – Measure, Multi-Mode (MM) Measurement All to 2 dBm Max 635 nm (± 30 nm) 850 nm (± 30 nm) 1300 nm (± 30 nm) 0.59 dB RIFOCS/tempo OPM system Optical Power – Measure, Single Mode (SM) Measurement – Laser Only 1310 nm, 1490 nm 1550 nm, 1625 nm All (± 30 nm) 0.59 dBm RIFOCS/tempo OPM system Optical Attenuation (Att.) and Insertion Loss (IL.) – Measure, Single Mode (SM) Measurement – Laser Only 1310 nm, 1490 nm 1550 nm, 1625 nm All (± 30 nm) 0.59 dB RIFOCS/tempo OPM system ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eithe r a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
to 2 dBm
6ISO/IEC 17025:2017; R205--
7ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

551 Fifth St. Unit B2, San Fernando, CA, 91340, US

34.28497, -118.43765

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.