Registers refreshed 2026-11-20.See refresh dates
France

LABORATOIRE ICARE

Biopôle Clermont Limagne BP 60006, 63360, SAINT-BEAUZIRE, France

Visit website
COFRAC 1-1021ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
19
COFRAC certificate
1
Sites in our directory
2
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 19 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO6
ISO 9377-2Water quality - Determination of hydrocarbon oil index - Part 2: Method using solvent extraction and gas chromatography
ISO 10993-7Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals
ISO 14644-1Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration
ISO 14644-3Cleanrooms and associated controlled environments - Part 3: Test methods
ISO 14698-1Cleanrooms and associated controlled environments - Biocontamination control - Part 1: General principles and methods
ISO 19227Implants for surgery - Cleanliness of orthopedic implants - General requirements
USP4
USP 61
USP 71
USP 85
USP 643
EN3
EN 12469
EN 14683
EN 17141Cleanrooms and associated controlled environments - Biocontamination control
ISO 11138 series3
ISO 11138-1Sterilization of health care products - Biological indicators - Part 1: General requirements
ISO 11138-2Sterilization of health care products - Biological indicators - Part 2: Biological indicators for ethylene oxide sterilization processes
ISO 11138-3Sterilization of health care products - Biological indicators - Part 3: Biological indicators for moist heat sterilization processes
ISO 11737 series3
ISO 11737-1Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microorganisms on products
ISO 11737-2Sterilization of health care products - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process
ISO 11737-3Sterilization of health care products - Microbiological methods - Part 3: Bacterial endotoxin testing

Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-20.

Scope as published by COFRAC

12 lines
COFRAC

ISO/IEC 17025

Active

1-1021

The scope document we hold says it is valid until 2029-07-31.

View scope

Location

Biopôle Clermont Limagne BP 60006, SAINT-BEAUZIRE, 63360, FR

45.85163, 3.17901

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.