Registers refreshed 2026-11-08.See refresh dates
France

CESTI LETI

CEA-Leti, MINATEC Campus, DRT/LETI/DSYS/SSSEC/CESTI 17 AVENUE DES MARTYRS, 38054, GRENOBLE, France

COFRAC 1-1294ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
1
COFRAC certificate
1
Sites in our directory
2
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 15408

Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-06.

Scope as published by COFRAC

8 lines
COFRAC

ISO/IEC 17025

Active

1-1294

The scope document we hold says it was valid until 2026-09-30. That date has passed, so our copy may be out of date. We downloaded it from the COFRAC register on 2026-02-12. Check the COFRAC register for the current scope.

View scope

Accredited scope, certificate 1-1294

LineMethodMatrixRange
1NF EN ISO/IEC 17025--
2ISO/CEI 15408; ISO/IEC 15408--
3ITSEM; CEMv2.x; CEMv3.x; CEMv2022; AIS34; ANSSI Note/09 "E-passeport : utilisation du profil de protection EAC"; ANSSI Note/13 "Interprétation du composant d'assurance ALC_FLR.3"; CCDB-2007-11-001; ANSSI Note/02 "Visite de l'environnement de développement"; ANSSI Note/17 "Réutilisation des composants d'assurance ALC"; PME.4.007; PME.4.016Documents liés à l'environnement de développement (procédures, plans et documents de gestion de configuration, procédures de livraison, procédures d'installation, de génération et de démarrage, documents de sécurité du développement, procédure de correction d'erreurs, modèle et documents de cycle de vie, documents sur les outils de développement); Politique de sécurité physique et organisationnelle, gestion de configuration; Sites de développement ou de fabrication-
4ITSEM; CEMv2.x; CEMv3.x; CEMv2022; AIS34; ANSSI Note/06; ANSSI Note/10; ANSSI Note/12; EMVCo; CAST; VCSP; PME.4.010; PME.4.011; PME.4.012; PME.4.014; PME.4.018; ANSSI Note/05; PME.4.019Produit développé-
5CC (Common Criteria)composants électroniques, microélectroniques et logiciels embarqués-
6LAB REF 34--
7ANSSI-NOTE-06; ANSSI-NOTE-09; ANSSI-NOTE-10; PME.4.010; ANSSI-NOTE-13; ANSSI-NOTE-02; ANSSI-NOTE-17; JIL MSSR; PME.4.007--
8CEM; ANSSI-NOTE-12; PME.4.010; PME.4.018; ANSSI-NOTE-05; PME.4.012; PME.4.019; ANSSI-NOTE-24; RGS; SOG-IS Agreed Cryptographic Mechanims; PME.4.009; JIL Application of Attack Potential to smartcards; JIL Application of Attack-Potential to Hardware Devices with Security BoxesLangages C/C++, Java Card, assembleur; Modèles formels; Documentation de tests; Générateurs physiques de nombres aléatoires; Cryptographie; Composants sécurisés et cartes à puces; Equipement matériel avec boîtiers sécurisés-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

CEA-Leti, MINATEC Campus, DRT/LETI/DSYS/SSSEC/CESTI 17 AVENUE DES MARTYRS, GRENOBLE, 38054, FR

45.18756, 5.73578

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.